Balancing and Settlement Code
BSC PROCEDURE
NON-HALF HOURLY DATA COLLECTION FOR SVA METERING SYSTEMS REGISTERED IN SMRS
BSCP504
Date: |
Version | Date | Description of Changes | Changes Included | Mods Panel Ref |
D0.1 | Code Effective Date | Re-Badged |
|
|
D0.2 | Code Effective Date | Incorporate version D.01 review comments |
|
|
D0.3 | Code Effective Date | Incorporate version D.02 review comments |
|
|
D.04 | Code Effective Date | Comments embodied following CMC1273 |
|
|
2.0 | Code Effective Date | Approved for use by the Panel |
|
|
3.0 | Code Effective Date | Version alignment changes from AP504 embodied. | NCR329 |
|
4.0 | 27/03/01 | Further changes embodied for NCR329. | NCR329 |
|
5.0 | 03/02/03 | SVA Documentation Batch Release. | CPs 698, 752, 768, 778, 787, 789, 799 | SVG/22/275 |
6.0 | 17/02/03 | Incorporates changes for P63. | P63 | SVG/20/251, SVG/21/256 |
7.0 | 01/08/03 | Updated for Modification P62. | P62 | SVG/29/390 |
8.0 | 28/08/03 | August SVA Documentation Batch Release. | CP854 | SVG/30/397 |
9.0 | 28/09/03 | Incorporates changes for P81 | P81 | SVG/31/414 |
10.0 | 04/11/03 | SVA November 2003 Release. | P107, CP868, CP913, CP922, CP939 | SVG/33/442 |
11.0 | 04/11/04 | SVA November 2004 Release. | P124, CP955, CP1025, CP1032 | TDC/58/03, SVG/43/003 |
12.0 | 23/02/05 | SVA February 2005 Release and BETTA 6.3 | CP834, CP844, CP1010, CP1019, CP1020, CP1055, CP1064 and CP1091 BETTA 6.3 | SVG/47/004 |
13.0 | 30/06/05 | SVA June 05 Release | CP1079 | SVG/51/004 |
14.0 | 03/11/05 | SVA November 2005 Release | CP1036, CP1037, CP1039, CP1107, CP1132, CP1139, P176, P183. | SVG/56/004, SVG/57/002 |
15.0 | 23/02/06 | SVA February Release | CP1102, CP1122, CP1123, CP1124, CP1125, CP11321 CP1133, CP1134, CP1151. | SVG/51/003, SVG/52/002, SVG/53/002, SVG/58/003 |
16.0 | 02/11/06 | November 06 Release | CP1138, CP1039 | SVG/56/003, SVG/44/004 |
17.0 | 22/02/07 | February 07 Release. Updated Following Industry review | P196, CP1165, CP1168, CP1176 | SVG/66/04, SVG67/17, ISG68/02 |
18.0 | 28/06/07 | June 07 Release. Updated terminology in preparation for P197 Release | CP1179, P197 | SVG/70/03 |
19.0 | 26/06/08 | June 08 Release | CP1223, CP1226, CP1230 | SVG84/02, ISG84/01, TDC109/01, PAB84/11, SVG85/01, SVG85/02 |
20.0 | 06/11/08 | November 08 Release | CP1229, CP1234 | SVG85/01, SVG87/02, ISG87/02, PAB87/09 |
21.0 | 26/02/09 | February 09 Release | CP1252, CP1253 | SVG93/02, SVG93/02, PAB93/10, ISG93/02 |
22.0 | 25/06/09 | June 09 Release | CP1256, CP1266, CP1274 | SVG93/02, SVG97/02, SVG97/02 |
23.0 | 05/11/09 | November 09 Release | CP1281 | SVG99/02 |
24.0 | 25/02/10 | February 2010 Release | CP1304, CP1306, CP1308, CP1307, CP1310, CP1312 | SVG104/01, SVG105/02 |
25.0 | 31/03/10 | Modification P245 | P245 Alt | Panel |
26.0 | 24/06/10 | June 2010 Release | CP1311 | SVG105/02 |
27.0 | 01/11/10 | November 2010 Release | CP13252 | SVG111/01 |
| 04/11/10 | November 2010 Release | P2573 | Panel |
28.0 | 01/07/11 | June 2011 Release | CP13344 | SVG114/02 |
29.0 | 03/11/11 | November 2011 Release | CP1335 | ISG114/01, SVG114/02 |
30.0 | 28/06/12 | June 2012 Release | CP1366 | SVG134/02 |
31.0 | 27/06/13 | June 2013 Release | CP1376 | SVG139/08 |
32.0 | 07/11/13 | November 2013 Release | CP1360 v2.0 | SVG148/03 |
33.0 | 27/02/14 | February 2014 Release | CP1401 | SVG154/04 |
34.0 | 06/11/14 | November 2014 Release | CP1405 | SVG157/06 |
35.0 | 26/02/15 | February 2015 Release | CP1395 | P217/06 |
36.0 | 25/06/15 | June 2015 Release | CP1409 | SVG160/06 |
|
|
| CP1415 | SVG163/03 |
|
|
| CP1416 | SVG163/04 |
|
|
| CP1417 | SVG163/05 |
37.0 | 05/11/15 | November 2015 Release | P305 | SVG176/03 |
38.0 | 30/06/16 | June 2016 Release | P302 | P239/06 |
|
|
| CP1446 | SVG177/04 |
|
|
| CP1447 | SVG177/05 |
39.0 | 23/02/17 | February 2017 Release | CP1473 | SVG191/02 |
40.0 | 29/06/17 | June 2017 Release | CP1474 | SVG191/03 |
41.0 | 28/06/18 | June 2018 Release | CP1501 | SVG204/07 |
42.0 | 29/03/19 | 29 March 2019 Standalone Release | P369 | P285/12 |
43.0 | 27/06/19 | June 2019 Release | CP1514 | SVG216/05 |
|
|
| P367 Self-Governance | SVG219/02 |
44.0 | 12/10/20 | P397 Standalone Release | P397 | P298/05 |
45.0 | 05/11/20 | November 2020 Release | CP1529 | SVG233/03 |
46.0 | 25/02/21 | February 2021 Release | CP1533, CP1534 | SVG235/06 SVG235/04 |
47.0 | 01/09/21 | September 2021 Release | P420 | P316/05 |
48.0 | 30/06/2022 | June 2022 Release | CP1532 | SVG235/05 |
49.0 | 18/07/22 | July 2022 Non Standard Release | P436 | P325/05 |
50.0 | 03/11/2022 | November 2022 Release | CP1560 | ISG253/05 and SVG255/04 |
51.0 | 29/06/2023 | June 2023 Release | CP1580 | P338/04 |
Collect the Metered Data (in accordance with this BSCP);
Check the Metered Data and provide reports (in accordance with this BSCP);
Enter the Metered Data in kWh into the relevant data collection system and calculate Meter Advance values for each Settlement Register;
receive Daily Profile Coefficients from the SVAA;
Investigate inconsistencies in EAC/AA data as provided by the NHHDA, SVA MOA or Supplier;
Update standing entries and Meter Technical Details to take account of new information;
Determine EAC and AA data;
Provide AA data including their Effective From and To Settlement dates, EAC data including their Effective From Settlement date and Metering system details to the NHHDA;
Provide validated Metered Data and Metering System Reports to the Supplier and LDSO;
Calculate a Meter Advance or Deemed Meter Advance values for each Settlement Register, in accordance with Annex S-2 of the BSC and this BSCP);
For a change of Supplier, the old Supplier and old NHHDC shall provide historical data as required by the BSC Annex S-2 and this BSCP to the new Supplier and new NHHDC;
For Unmetered Supplies which are not subject to Equivalent Metering, the NHHDC shall set values of EAC to be defined in the relevant UMS (Unmetered Supply) certificate, pass such values unadjusted to the NHHDA responsible for such Unmetered Supply, together with the Effective from Settlement Dates of the EAC; and
When advised by a Supplier that a site is Long Term Vacant site, calculate a Metered Advance or Deemed Meter Advance and an EAC for each Settlement Register and thereafter replace the EAC with an EAC of zero value. When a site can no longer be treated as Long Term Vacant, calculate Metered Advance, a Deemed Meter Advance and an EAC for each Settlement Register and use these to replace the zero value EAC for future calculations.
Where a Demand Disconnection occurs as part of a Demand Control Event, the NHHDC shall calculate values of Annualised Advances relating to each impacted MSID so as to accurately reflect the effect of the disconnection, and shall pass these such values to the relevant NHHDA.
Positive and negative Meter advances;
Positive and negative EACs and AAs;
Positive and negative Daily profile coefficients.
BSCP01 | Overview of Trading Arrangements |
BSCP11 | Trading Disputes |
BSCP502 | Half Hourly Data Collection for SVA Metering Systems Registered in SMRS |
BSCP505 | Non-Half Hourly Data Aggregation for SVA Metering Systems Registered in SMRS |
BSCP508 | Supplier Volume Allocation Agent |
BSCP513 | Bulk Change of Non-Half Hourly Supplier Agent |
BSCP515 | Licensed Distribution |
BSCP516 | Allocation of Profiles and SSCs for Non-Half Hourly SVA Metering Systems Registered in SMRS |
BSCP520 | Unmetered Supplies Registered in SMRS |
AA(s) | Annualised Advance(s) |
BSC | Balancing and Settlement Code |
BSCCo | Balancing and Settlement Code Company |
CoMC | Change of Measurement Class |
CoP | Code of Practice |
CoS | Change of Supplier |
CSS | Central Switching Service |
CT | Current Transformer |
CTCU | Central Teleswitching Control Unit |
DCC | Data Communications Company |
DCE | Demand Control Event |
DTN | Data Transfer Network |
DTS | Data Transfer Service |
EAC(s) | Estimated Annual Consumption(s) |
EMDS | Energy Market Data Specification |
GSP | Grid Supply Point |
HH | Half Hourly |
HHDC | Half Hourly Data Collector |
HV | High Voltage |
Id | Identifier |
kVA | Kilo-Volt-Amperes |
kW | Kilowatt |
kWh | Kilowatt Hour |
LDSO | Licensed Distribution System Operator |
LF | Load Factor |
LTV | Long Term Vacant |
MAP | Meter Advance Period |
MC(s) | Measurement Class(es) |
MD | Maximum Demand |
MDD | Market Domain Data |
MDDM | Market Domain Data Manager |
MDR | Maximum Demand Register |
ME | Metering Equipment |
MS | Metering System |
MSID | Metering System Identifier |
MTD | Meter Technical Details |
NETSO | National Electricity Transmission System Operator as the holder of the Transmission Licence and any reference to "NETSO", "NGESO", "National Grid Company" or "NGC" in the Code or any Subsidiary Document shall have the same meaning |
NHHDA(s) | Non-Half Hourly Data Aggregator(s) |
NHHDC(s) | Non-Half Hourly Data Collector(s) |
NOSI | Notification of Old Supplier Information |
PA | Profile Administrator |
PC | Profile Class |
PFSR | Post Final Settlement Run |
PoS | Point of Sale (or early reading) |
REC | Retail Energy Code |
Ref | Reference |
RF | Reconciliation Final (Final Reconciliation Run) |
RPS | Revenue Protection Service |
SAR | Supplier Agreed Read |
SD | Settlement Day |
SFIC | Systems Fault Information Centre |
SMETS | Smart Metering Equipment Technical Specifications |
SSC(s) | Standard Settlement Configuration(s) |
SSD | Supply Start Date |
SVAA | Supplier Volume Allocation Agent |
SVA MOA | SVA Meter Operator Agent |
SVAS | Supplier Volume Allocation System |
TPR(s) | Time Pattern Regime(s) |
UMS | Unmetered Supplies |
UMSO | Unmetered Supplies Operator |
UTC | Coordinated Universal Time |
WD | Working Day |
Deemed Meter Reading | A Meter reading calculated by adding or subtracting a Deemed Meter Advance from a Meter register reading. |
Supplier Agreed Reading | A Meter reading which is agreed between the new Supplier and the old Supplier in accordance with Annex S-2 4.2.1(c)(i) of the Code, and in the specific circumstances when a CoS (Change of Supplier) Reading has not been obtained at least 30WD after the CoS but no more than 12 months after the CoS (i.e. not a disputed read or an old Supplier Estimated read). |
Point of Sale Reading | A Meter reading obtained by the new Supplier during the period between the customer entering into the contract and the start of the CoS meter reading window. |
HHDC-serviced Metering System | A Metering System where the HHDC is responsible for collecting data directly from the Metering System. |
Supplier-serviced Metering System | A Metering System where the Supplier obtains data from a SMETS compliant Meter, either directly or using a service provider. |
Last Valid EAC | defined in section 4.5 |
Crystallised Period | defined in section 4.14 |
Error Freezing Reading | defined in section 4.14 |
Fluid Period | defined in section 4.14 |
Realistic Reading | defined in section 4.14 |
RF Window | defined in section 4.14 |
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.1.1.1 | If required. | Request MDD. | NHHDC. | MDDM. | NHHDC Id. | Electronic or other method, as agreed. |
3.1.1.2 | When published by SVAA or within 1 WD of request from NHHDC. | Send MDD. | SVAA. | NHHDC. | D0227 BSCCo Market Domain Data File. D0269 Market Domain Data Complete Set. D0270 Market Domain Data Incremental Set. P0190 GSP Group Profile Class Tolerances. | Manual Process. |
3.1.1.3 | Within 4 working hours of receipt of MDD. | Send acknowledgement that data has been received. | NHHDC. | MDDM. | P0024 Acknowledgement | Electronic or other method, as agreed. |
3.1.1.4 | As and when needed | Record and use MDD as is considered appropriate by the Panel (having regard to the NHHDC’s functions) and in particular, use only MDD for those items in relation to which there is a Market Domain Data entry. | NHHDC. |
|
| Internal Process. |
3.1.1.5 | If file not readable and / or incomplete. | Send notification and await receipt of MDD. | NHHDC. | MDDM. | P0035 Invalid Data. | Electronic or other method, as agreed. |
3.1.1.6 | After receiving notification. | Send corrected MDD. Return to 3.1.1.2. | SVAA. | NHHDC. | Refer to 3.1.1.2 for data flows. | Electronic or other method, as agreed. |
3.1.1.7 | As soon as possible after data in correct format. | Update database. | NHHDC. |
|
| Internal Process. |
3.1.1.8 | On receipt of new Market Domain Data. | Ensure that all MDD affecting the accuracy of Settlement which is manually entered by the NHHDC is validated against the source data supplied by the SVAA, before the data is recorded and used. | NHHDC |
|
| Internal Process |
3.1.1.9 | In the event of a dispute. | In the event of any dispute as to whether an item of Market Domain Data is appropriate or, as the case may be, affects the accuracy of Settlement, the decision of the Panel shall be conclusive. |
|
|
|
|
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.1.2.1 | On demand when appointed to SVA MS. | Request and record relevant Daily Profile Coefficients in accordance with BSCP508. | NHHDC. | SVAA. | P0040 Request Daily Profile Coefficient Data. | Manual Process. |
3.1.2.2 | a) After Profile Production Run - by 5:00pm on SD+1 or | Send accepted Daily Profile Coefficients, for the Settlement Day(s)8 for one or more GSP Group(s). | SVAA. | NHHDC. | D0029 Standard Settlement Configuration Report. D0039 Daily Profile Coefficient File | Electronic Interface. |
| b Re-submit or withdraw profiles already sent or | The data flows produced and sent will contain data which is a number of days in arrears of the Settlement Day to which they relate. |
| Supplier. | D0018 Daily Profile Data Report. D0029 Standard Settlement Configuration Report. |
|
| c) Upon request from NHHDC via 3.1.2.1. |
|
|
| P0043 Teleswitch Report. |
|
3.1.2.3 | If required. | Request Standing Profile Data Report | NHHDC, Supplier | SVAA |
| Manual Process. |
3.1.2.4 | Following 3.1.2.3 | Send Standing Profile Data Report by manual method. | SVAA | NHHDC, Supplier | D0028 Standing Profile Data Report | Manual Process |
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.2.1.1 | On appointment of a new NHHDC | Send notification of appointment and associated Agent details to the NHHDC. | Supplier9. | NHHDC. | D0148 Notification of Change to Other Parties. D0155 Notification of New Meter Operator or Data Collector Appointment and Terms. D0302 Notification of Customer Details | Electronic or other method, as agreed. |
3.2.1.2 | Within 10 WD of completion of Meter installation. | Send NHH Metered Data, including MTD, energisation status and initial Meter register reading, where obtained. | SVA MOA.10 | NHHDC. NHHDC, Supplier, LDSO. | D0010 Meter Readings. D0149 Notification of Mapping Details D0150 Non-Half Hourly Meter Technical Details. | Electronic or other method, as agreed. |
|
|
|
| NHHDC Supplier | D0313 Auxiliary Meter Technical Details (in accordance with Appendix 4.20) |
|
3.2.1.3 | Within 5 WD of receipt of D0150 from the SVA MOA | Send SVA Metering System details, including initial (class average) EAC to the NHHDC. | Supplier | NHHDC SMRA | D0052 Affirmation of Metering System Settlement Details. D0205 Update Registration Details See Appendix 4.12 – Usage and Validation of Affirmation of Metering System Settlement Details (D0052) Flow. | Electronic or other method, as agreed. |
3.2.1.4 | On receipt of D0052 and D0150 | Validate D0052. Check for discrepancies between the Metering System Settlement Details provided by the Supplier and the Meter Technical Details provided by the SVA MOA. | NHHDC |
| See Appendix 4.12 – Usage and Validation of Affirmation of Metering System Settlement Details (D0052) Flow | Internal |
3.2.1.5 | On appointment of a new NHHDC | Validate details of each SVA Metering System against MDD supplied by the SVAA. | NHHDC |
|
| Internal Process. |
3.2.1.6 | If D0052 invalid | Send notification of invalid Metering System Settlement details to Supplier | NHHDC | Supplier | D0310 Notification of Failure to Load or Receive Metering System Settlement Details11 | Electronic or other method, as agreed. |
3.2.1.7 | On receipt of D0310 | Supplier should resolve the problem by re-sending or revising the D0052 as required or by instructing the SVA MOA to re-send the D0150. | Supplier | NHHDC SMRA | D0052 Affirmation of Metering System Settlement Details. D0205 Update Registration Details As required | Electronic or other method, as agreed. |
3.2.1.8 | On receipt of valid D0052 | Send the initial (class average) EAC for each Settlement register of the SVA MS to the NHHDA. Process EAC/AA data in accordance with section 3.5. | NHHDC. | NHHDA. | D0019 Metering System EAC/AA Data. | Electronic or other method, as agreed. |
3.2.1.9 |
| Process and validate Meter register reading. | NHHDC. |
| Appendix 4.2 - Validate Meter Data, Appendix 4.6 – Manual Adjustment of Meter Reading(s). | Internal Process. |
3.2.1.10 | If invalid Meter register reading. | Produce and send Invalid Data Report. | NHHDC. | Supplier, LDSO. | D0010 Meter Readings. | Electronic or other method, as agreed. |
3.2.1.11 | If valid Meter register reading. | Produce and send Valid Data Report. | NHHDC. | Supplier, LDSO. | D0010 Meter Readings. | Electronic or other method, as agreed. |
3.2.1.12 | If required and no valid Meter register reading received within 10 WD of the installation of the Meter | Request initial Meter register reading | NHHDC | SVA MOA, Supplier |
| Post / Fax / Email |
3.2.1.13 | Within 10WD of 3.2.1.12 | Send initial Meter register reading | SVA MOA, Supplier | NHHDC12 | D0010 Meter Readings | Electronic or other method, as agreed |
3.2.1.14 | If required and at least 10 WD after 3.2.1.12 and by 10WD before the Final Reconciliation Run for the relevant Settlement Date, if no valid initial Meter register reading has been received | Deem initial Meter reading in accordance with Appendix 4.5 and calculate associated EAC / AA(s) | NHHDC |
| Appendix 4.5 – Deemed Meter Advance Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Internal Process |
3.2.1.15 | Following 3.2.1.14 | Send Deemed Meter Reading | NHHDC | Supplier, LDSO | D0010 Meter Readings | Electronic or other method as agreed |
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.2.3.1 | By 12 WD prior to effective date of DC appointment. | Send notification of appointment. The Supplier will notify the New NHHDC if the Metering System has a smart Meter using the Contract Reference (or by other means, as agreed). | Supplier. | New NHHDC. | D0155 Notification of New Meter Operator or Data Collector Appointment and Terms. | Electronic or other method, as agreed. |
3.2.3.2 | By 7 WD prior to effective date of DC appointment. | Send confirmation of appointment acceptance. | New NHHDC. | Supplier. | D0011 Agreement of Contractual Terms. | Electronic or other method, as agreed. |
3.2.3.3 | By 5 WD prior to effective date of DC appointment. | Send associated Agent details. | Supplier14. | New NHHDC, SVA MOA | D0148 Notification of Change to Other Parties. D0302 Notification of Customer Details | Electronic or other method, as agreed. |
3.2.3.4 | By 3 WD prior to effective date of DC appointment. | Send notification of de-appointment. | Supplier. | Old NHHDC15. | D0151 Termination of Appointment or Contract by Supplier. | Electronic or other method, as agreed. |
3.2.3.5 | Between –7 WD and the de-appointment date. | Send request to provide Meter register reading and associated AA/EAC history to new NHHDC. | Supplier. | Old NHHDC. | D0170 Request Metering System Related Details. | Electronic or other method, as agreed. |
3.2.3.6 | Within 5 WD of de-appointment16. | Send Meter register reading and associated AA/EAC history17. | Old NHHDC. | New NHHDC. | Appendix 4.8 – Historical Data Requirements. | Electronic or other method, as agreed. |
|
| In addition, if an actual or customer Meter register reading(s) is obtained by 8WDs (i.e. profile coefficients have been received) before the appointment date change, then this reading(s) will be validated and processed prior to it being sent to the new NHHDC. |
|
| D0010 Meter Readings. D0152 Metering System EAC/AA Historical Data. |
|
|
| If an actual or customer Meter register reading(s) is obtained but less than 8WDs before the appointment date change, then this reading(s) will, wherever possible, be validated and sent to the new NHHDC. |
|
|
|
|
3.2.3.7 | Within 1 WD of 3.2.3.6. | If Meter register reading and associated AA/EAC history not received as expected, request this data. | New NHHDC. | Supplier18 or old NHHDC | D0170 Request for Metering System Related Details. | Electronic or other method, as agreed. |
3.2.3.8 | Within 1 WD of 3.2.3.7. | Send Meter register reading and associated AA/EAC history. | Old NHHDC or Supplier18 | New NHHDC. | Appendix 4.8 – Historical Data Requirements. D0010 Meter Readings. D0152 Metering System EAC/AA Historical Data. | Electronic or other method, as agreed. |
3.2.3.9 | If further meter readings are received by the old NHHDC after historical information has been transferred to the new NHHDC | Old NHHDC to send additional information to the New NHHDC | Old NHHDC | New NHHDC |
| Electronic or other method, as agreed. |
3.2.3.10 | If required | Request SVA MS data | NHHDC | Supplier | D0170 Request for Metering System Related Details | Electronic or other method, as agreed |
3.2.3.11 | Only following 3.2.3.10 or if concurrent change of MS Settlement Details | The Supplier will provide this data to the new NHHDC via the D0052 Affirmation of SVA MS Settlement Details. | Supplier | New NHHDC SMRA | D0052 Affirmation of Metering Settlement Details | Electronic or other method, as agreed |
3.2.3.12 | Following request from Supplier and within 10 WD of effective date of DC appointment. | Send current MTD. Send details of any current faults. | SVA MOA. | New NHHDC. | D0149 Notification of Mapping Details. D0150 Non-Half Hourly Meter Technical Details. | Electronic or other method, as agreed. |
|
|
|
|
| D0313Auxiliary Meter Technical Details (in accordance with Appendix 4.20) |
|
|
|
|
|
| D0002 Fault Resolution Report or Request for Decision on Further Action |
|
3.2.3.13 | Within 1 WD of 3.2.3.10. | If MTD not received as expected, request this data. | New NHHDC. | SVA MOA. | D0170 Request for Metering System Related Details. | Electronic or other method, as agreed. |
3.2.3.14 | Within 1 WD of 3.2.3.11 request from new NHHDC. | Send current MTD. | SVA MOA. | New NHHDC. | D0149 Notification of Mapping Details. D0150 Non-Half Hourly Meter Technical Details. | Electronic or other method, as agreed. |
|
|
|
|
| D0313 Auxiliary Meter Technical Details (in accordance with Appendix 4.20) |
|
3.2.3.15 | As soon as practical. | Confirm inclusion of SVA MS in Meter register reading schedule. | New NHHDC. | Supplier, LDSO. | D0012 Confirmation of the Inclusion of the Metering Point in the Reading Schedules. | Electronic or other method, as agreed. |
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.2.4.1 | On appointment of new SVA MOA. | Send notification19 of new SVA MOA to NHHDC. | Supplier. | NHHDC. | D0148 Notification of Change to Other Parties. D0302 Notification of Customer Details. | Electronic or other method, as agreed. |
3.2.4.2 |
| Send MTD. | New SVA MOA. | NHHDC. | D0149 Notification of Mapping Details. D0150 Non-Half Hourly Meter Technical Details. | Electronic or other method, as agreed. |
|
|
|
|
| D0313 Auxiliary Meter Technical Details (in accordance with Appendix 4.20) |
|
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.2.5.1 | Once NHHDA appointment effective in SMRS. | Send notification of new NHHDA to NHHDC. | Supplier. | NHHDC20. | D0148 Notification of Change to Other Parties. | Electronic or other method, as agreed. |
3.2.5.2 | If there is a valid reading for the NHHDA appointment date (i.e. there is a MAP ending on the day prior to the NHHDA appointment date). | Calculate the AA and EAC for the MAP. | NHHDC. |
|
| Internal Process. |
3.2.5.3 | Following 3.2.5.2. | Send the AA to the old NHHDA and Supplier. | NHHDC. | Old NHHDA, Supplier. | D0019 Metering System EAC/AA Data. | Electronic or other method, as agreed. |
|
| Send the EAC to the new NHHDA and Supplier. | NHHDC. | New NHHDA, Supplier. | Process EAC/AA data in accordance with section 3.5. |
|
3.2.5.4 | Otherwise, if a valid reading is processed after 3.2.5.1 and with a MAP ending before the day prior to the change of NHHDA appointment date. | Calculate the AA and EAC for the MAP. | NHHDC. |
|
| Internal Process. |
3.2.5.5 | Following 3.2.5.4. | Send the AA to the old NHHDA and Supplier. | NHHDC. | Old NHHDA, Supplier. | D0019 Metering System EAC/AA Data. | Electronic or other method, as agreed. |
|
| Send the EAC to the new and old NHHDA and Supplier. | NHHDC. | New and old NHHDA, Supplier. | Process EAC/AA data in accordance with section 3.5. |
|
3.2.5.6 | If no reading processed prior to the change of NHHDA, then by no later than 8 WD after the effective date of the new NHHDA appointment. | Send latest EAC to new NHHDA. | NHHDC21. | New NHHDA. | D0019 Metering System EAC/AA Data.
Process EAC/AA data in accordance with section 3.5. | Electronic or other method, as agreed. |
3.2.5.7 | On processing of the first valid reading subsequent to the change of NHHDA (i.e. where the MAP spans the change of NHHDA appointment date). | Calculate the AA and EAC for the MAP. | NHHDC. |
|
| Internal Process. |
3.2.5.8 | Following 3.2.5.7. | Send the AA to the new and old NHHDA and Supplier. | NHHDC | New and old NHHDA, Supplier. | D0019 Metering System EAC/AA Data. | Electronic or other method, as agreed. |
|
| Send the EAC to the new NHHDA and Supplier. | NHHDC | New NHHDA, Supplier | Process EAC/AA data in accordance with section 3.5. |
|
3.2.5.9 | For all subsequent readings (i.e. for MAPs beginning on or after the change of NHHDA appointment date). | Calculate the AA and EAC for the MAP. | NHHDC |
|
| Internal Process. |
3.2.5.10 | Following 3.2.5.9. | Send the AA and EAC to new NHHDA and Supplier. | NHHDC. | New NHHDA, Supplier. | D0019 Metering System EAC/AA Data. Process EAC/AA data in accordance with section 3.5. | Electronic or other method, as agreed. |
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
For all SVA NHH Metering Systems | ||||||
3.2.6.1 | By SSD – 1 WD. | Send appointment. The Supplier will notify the new NHHDC if the Metering System has a DCC serviced smart Meter. | New Supplier. | New NHHDC. | D0155 Notification of New Meter Operator or Data Collector Appointment and Terms. | Electronic or other method, as agreed. |
3.2.6.2 | If appointment rejected and within 2 WD of 3.2.6.1 | Send notification of rejection of appointment including the reason why the request has been rejected. | New NHHDC | New Supplier | D0261 Rejection of Agent Appointment. Go to 3.2.6.1 if required | Electronic or other method, as agreed. |
3.2.6.3 | If appointment accepted and within 2 WD of 3.2.6.1 | The new NHHDC will confirm appointment with the new Supplier. | New NHHDC. | New Supplier. | D0011 Agreement of Contractual Terms. | Electronic or other method, as agreed. |
3.2.6.4 | On appointment of SVA MOA and within 1 WD of 3.2.6.323 | Send notification of old NHHDC, new NHHDA and new SVA MOA (as applicable). For DCC serviced SVA NHH Metering Systems24, proceed to 3.2.6.40. For non DCC serviced NHH Metering Systems, where the new NHHDC is the same as the old NHHDC, proceed to 3.2.6.9. | New Supplier | New NHHDC | D0148 Notification of Change to Other Parties. | Electronic or other method, as agreed. |
For non DCC serviced SVA NHH Metering Systems24 | ||||||
3.2.6.4(a) | By New Supplier SSD | Send notification of termination of appointment. | Old Supplier | Old NHHDC | D0151 Termination of Appointment or Contract by Supplier. | Electronic or other method, as agreed |
3.2.6.5 | If concurrent change of MS Settlement Details | The Supplier will provide this data to the NHHDC. | New Supplier | New NHHDC SMRA | D0052 Affirmation of Metering Settlement Details D0205 Update Registration Details See also Appendix 4.12 - Usage and Validation of Affirmation of Metering System Settlement Details (D0052) flow. | Electronic or other method, as agreed |
3.2.6.6 | As required and within 1 WD of 3.2.6.4 (or 3.2.6.43 as applicable) and once registration notification received. | Send request to old NHHDC to send Meter register reading and associated EAC. | New NHHDC. | Old NHHDC. | D0170 Request for Metering System Related Details. | Electronic or other method, as agreed. |
3.2.6.7 | If applicable and within 2 WD of 3.2.6.6 provided an EAC has been calculated for latest valid reading or within 1 WD of EAC being calculated for latest valid reading if an EAC has yet to be calculated25. | Send Meter register reading and associated EAC. In addition, if the old NHHDC obtains an actual or a customer Meter register reading before the SSD, then ensure this reading(s) will be validated and processed prior to it being sent to the new NHHDC. Send the revised Meter register reading history to the new NHHDC.26 | Old NHHDC. | New NHHDC. | Appendix 4.8 – Historical Data Requirements. D0010 Meter Readings. D0152 Metering System EAC/AA Historical Data. | Electronic or other method, as agreed. |
3.2.6.8 | Within 1 WD of receipt of the D0148 (if no concurrent change of SVA MOA) or within 1 WD of receipt of MTD from Old SVA MOA (if concurrent change of SVA MOA). | Send the MTD to the new NHHDC. | SVA MOA. | New NHHDC. | D0149 Notification of Mapping Details. D0150 Non-Half Hourly Meter Technical Details. D0313 Auxiliary Meter Technical Details (in accordance with Appendix 4.20) | Electronic or other method, as agreed. |
3.2.6.9 | In time to achieve a read within SSD-5 and SSD+5. | Where desired by both Suppliers, for the purposes of correcting an erroneous registration, both Suppliers shall agree a Meter register reading equivalent to a 1kWh advance, since the erroneous registration, and provide the Meter register reading via 3.2.6.10 below. | New Supplier / Old Supplier. | Old Supplier / New Supplier. |
| Manual Process. |
3.2.6.10 | In time to achieve a read within SSD-5 and SSD+5. | Where actual Meter register reading required: |
|
|
|
|
|
| Send request to obtain an actual Meter register reading. | New Supplier | New NHHDC. | D0072 Instruction to Obtain Change of Supplier Reading. | Electronic or other method as agreed. |
|
| The new NHHDC will obtain a Meter register reading where instructed by the new Supplier27. | New NHHDC | New NHHDC. | D0071 Customer Own Reading or Supplier Estimate | Internal Process. Electronic or other method, as agreed. |
|
| Otherwise: Provide a remotely retrieved reading or the customer Meter register reading (which may include a PoS reading or an old Supplier Estimated reading)28. | New Supplier | New NHHDC | D0010 Meter Readings. |
|
|
| The SVA MOA may send a Meter register reading to the new NHHDC. | SVA MOA. | New NHHDC. |
|
|
3.2.6.11 | By SSD+8 and once profile coefficients received. | Select the CoS reading. Process and validate the Meter register reading, using the historic data provided by old NHHDC, where applicable (from 3.2.6.7) and the MTD provided by the SVA MOA (from 3.2.6.8). |
|
| Appendix 4.2 - Validate Meter Data, Appendix 4.4 -Change of Supplier Activities, Appendix 4.6 – Manual Adjustment of Meter Reading(s). | Internal Process. |
3.2.6.12 | If invalid Meter register reading obtained within SSD-5 and SSD+5 window. | Produce and send an Invalid Data Report29. | New NHHDC. | New Supplier, LDSO, Old NHHDC, if applicable. | D0086 Notification of Change of Supplier Readings. | Electronic or other method, as agreed. |
3.2.6.13 | Where the Supplier ceases to be responsible at the same time as the NHHDC is also ceasing to trade | Prepare and maintain plans that will enable the Panel to fulfil the obligations of the Supplier under the Code. | Old NHHDC | Panel | Plans should detail how the NHHDC will upon termination or expiry; make arrangements for the immediate transfer of data and other information to the Panel. | Electronic or other method, as agreed. |
3.2.6.14 | On receipt of Invalid Data Report. | Send a request to the new NHHDC to provide a Meter register reading to replace the invalid one already received. The new NHHDC will collect a Meter register reading, based on the request from the new Supplier. Return to 3.2.6.11. | New Supplier. New NHHDC. | New NHHDC. | D0072 Instruction to Obtain Change of Supplier Readings30. | Electronic or other method, as agreed.
Internal Process. |
3.2.6.15 | If valid Meter register reading obtained within SSD-5 and SSD+5 window. For prepayment Metering Systems refer to Appendix 4.11 - Prepayment Meters | Produce and send Valid Data Report. | New NHHDC. | New Supplier, LDSO. Old NHHDC, if applicable. | D0010 Meter Readings31. D0086 Notification of Change of Supplier Readings32. D0086 Notification of Change of Supplier Readings. Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Electronic or other method, as agreed. |
3.2.6.16 | a) If valid Meter register reading obtained outside SSD-5 and SSD+5 window but before SSD+8 and no valid Old Supplier Estimated reading was received between SSD+5 and SSD+8; or | Calculate a Deemed Meter Reading for the SSD using:
Send this Deemed Meter change of Supplier reading. | New NHHDC.
New NHHDC. |
New Supplier, LDSO, Old NHHDC, if applicable. | Appendix 4.5 – Deemed Meter Advance.
D0086 Notification of Change of Supplier Readings.
Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Internal Process.
Electronic or other method, as agreed. |
| b) If no valid Meter register reading obtained by SSD+8 and no valid Old Supplier Estimated reading was received between SSD+5 and SSD+8. |
|
|
|
|
|
3.2.6.17 | Following 3.2.6.16 and in sufficient time to enable the reading to be included in the Initial Settlement Run relating to the last Settlement Day for which the old Supplier is responsible. | Send this Deemed change of Supplier reading | Old NHHDC | Old Supplier | D0086 Notification of Change of Supplier Readings | Electronic or other method, as agreed |
3.2.6.18 | If no Meter reading history provided by the old NHHDC by SSD+5 or Meter reading history received but NHHDC not able to load it after making reasonable endeavours to do so. | Request Meter reading history | New NHHDC | Old NHHDC |
| Post / Fax / Email or other method as agreed. |
3.2.6.19 | Within 2 WD of 3.2.6.18 | Send Meter reading history | Old NHHDC | New NHHDC | D0010 Meter Readings D0152 Metering System EAC/AA Historical Data | Electronic or other method, as agreed |
3.2.6.20 | If no Meter reading history provided by the old NHHDC by SSD+5 or Meter reading history received but NHHDC not able to load it after making reasonable endeavours to do so. | New NHHDC may request Metering System Related Details | New NHHDC | New Supplier | D0170 Request for Metering System Related Details34 | Electronic or other method, as agreed |
3.2.6.21 | Within 2 WD of 3.2.6.20. | Send the EAC Details and Last Actual or Customer Register Reading (if available)35 | New Supplier36 | New NHHDC | D0311 Notification of Old Supplier Information (NOSI) Flow | Electronic or other method, as agreed. |
3.2.6.22 | When Meter reading history is provided, if a CoS reading is available | Select the CoS reading. Process and validate the Meter register reading, using the historic data provided by old NHHDC or the new Supplier and the MTD provided by the SVA MOA (from 3.2.6.8). Calculate associated EAC / AA(s) | New NHHDC |
| Appendix 4.2 - Validate Meter Data, Appendix 4.4 -Change of Supplier Activities, Appendix 4.6 – Manual Adjustment of Meter Reading(s). Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Internal Process |
3.2.6.23 | If invalid Meter register reading obtained within SSD-5 and SSD+5 window. | Produce and send an Invalid Data Report29 | New NHHDC. | New Supplier, LDSO, Old NHHDC, if applicable. | D0086 Notification of Change of Supplier Readings30. | Electronic or other method, as agreed. |
3.2.6.24 | If valid Meter register reading obtained within SSD-5 and SSD+5 window. For prepayment Metering Systems refer to Appendix 4.11 - Prepayment Meters | Produce and send Valid Data Report. | New NHHDC. | New Supplier, LDSO. Old NHHDC, if applicable | D0010 Meter Readings31. D0086 Notification of Change of Supplier Readings37. D0086 Notification of Change of Supplier Readings. Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Electronic or other method, as agreed. |
3.2.6.25 | When Meter reading history is provided, if a CoS reading is not available | Deem Meter reading in accordance with Appendix 4.5 and calculate associated EAC / AA(s) | New NHHDC |
| Appendix 4.5 – Deemed Meter Advance, Appendix 4.6 - Manual Adjustment of Meter Reading(s) Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Internal Process |
3.2.6.26 | Following 3.2.6.25 | Send resulting change of Supplier Meter Reading | New NHHDC | New Supplier, LDSO | D0086 Notification of Change of Supplier Readings. | Electronic or other method as agreed |
3.2.6.27 | If appropriate and at least 15 WD after the CoS but no more than 12 months after CoS. | If no CoS reading has been received by 15 working days, send SAR.39 | Old Supplier | New Supplier | D0300 Disputed Readings or Missing Readings on Change of Supplier | Electronic or other method, as agreed. |
3.2.6.28 | If appropriate and at least 17 WD after the CoS but no more than 12 months after CoS. | If no CoS reading has been received by 17 working days, send SAR. | New Supplier | New NHHDC | D0300 Disputed Readings or Missing Readings on Change of Supplier | Electronic or other method, as agreed. |
3.2.6.29 | Following 3.2.6.27 or 3.2.6.28 and when Meter reading history and MTDs are available. | Validate SAR. | New NHHDC |
| Appendix 4.2 - Validate Meter Data, Appendix 4.4 -Change of Supplier Activities. | Internal Process |
3.2.6.30 | Following 3.2.6.29 and if SAR is valid. | Send validated SAR. | New NHHDC | New Supplier, LDSO, old NHHDC if applicable. | D0086 Notification of Change of Supplier Readings. | Electronic or other method, as agreed. |
3.2.6.31 | Following 3.2.6.30 | Send validated SAR. | Old NHHDC | Old Supplier | D0086 Notification of Change of Supplier Readings. | Electronic or other method, as agreed. |
3.2.6.32 | Following 3.2.6.29 and if SAR is invalid. | Inform of invalid SAR. Go back to step 3.2.6.14, if appropriate. | New NHHDC | New Supplier | D0300 Disputed Readings or Missing Readings on Change of Supplier | Electronic or other method, as agreed. |
3.2.6.33 | At least 20 WD after 3.2.6.18 and no more than 12 months after 3.2.6.18, if no Meter reading history or reading have been received and if no valid reading obtained in 3.2.6.27-.3.2.6.32 | Obtain Meter register reading, deem initial Meter reading in accordance with Appendix 4.5 and calculate associated EAC / AA(s) | New NHHDC |
| Appendix 4.5 – Deemed Meter Advance Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Internal Process |
3.2.6.34 | Once Deemed Meter Reading has been calculated | Send this change of Supplier Deemed Meter Reading. | New NHHDC. | New Supplier, LDSO, Old NHHDC, if applicable. | D0086 Notification of Change of Supplier Readings. Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Electronic or other method as agreed |
3.2.6.35 | Following 3.2.6.34 | Send change of Supplier Deemed Meter Reading | Old NHHDC | Old Supplier | D0086 Notification of Change of Supplier Readings | Electronic or other method as agreed. |
3.2.6.36 | No later than 12 months after SSD, if the new Supplier wants to dispute the CoS reading prior to the Final Volume Allocation Run38. | Disagree reading and: a) Provide an actual or customer Meter register reading. b) Agree this Meter register reading with the old Supplier (Refer to the REC for further details). c) Send the agreed Meter register reading to the new NHHDC. Refer to 3.2.6.39. | New Supplier. New Supplier. New Supplier. | Old Supplier39 Old Supplier New NHHDC. | D0300 Disputed Readings or Missing Readings on Change of Supplier39. D0300 Disputed Readings or Missing Readings on Change of Supplier. D0300 Disputed Readings or Missing Readings on Change of Supplier. | Manual Process. |
3.2.6.37 | No later than 12 months after SSD if the old Supplier wants to dispute the CoS reading prior to the Final Volume Allocation Run38 | Disagree reading and: a) Send a request to the new Supplier to provide an actual Meter register reading or; (If option (a) selected, refer to 3.2.6.39.) b) Provide an actual or customer Meter register reading or c) Agree an alternative Meter register reading, to be used as the CoS reading, with the new Supplier38. d) Send the agreed Meter register reading to the new NHHDC. (If option b) or c) and d) selected, refer to 3.2.6.35.) | Old Supplier. Old Supplier.
Old Supplier.
New Supplier. | New Supplier. New Supplier39.
New Supplier.
New NHHDC. | D0300 Disputed Readings or Missing Readings on Change of Supplier. D0300Disputed Readings or Missing Readings on Change of Supplier39.
D0300 Disputed Readings or Missing Readings on Change of Supplier
D0300 Disputed Readings or Missing Readings on Change of Supplier | Manual Process. |
3.2.6.38 | On receipt of request from old Supplier. | Send request to new NHHDC to obtain a Meter register reading. | New Supplier. | New NHHDC. | D0072 Instruction to Obtain Change of Supplier Reading. | Electronic or other method, as agreed. |
3.2.6.39 | When Meter register reading has been agreed between Suppliers and is outside previous timescales but in time for the Final Volume Allocation Run. | Process and validate Meter register reading. | New NHHDC. |
| Appendix 4.2 - Validate Meter Data, Appendix 4.4 - Change of Supplier Activities; Appendix 4.6 – Manual Adjustment of Meter Reading(s). | Internal Process. |
|
| a) If valid, produce and send a Valid Data Report. Calculate a deemed Meter register reading39,40 for the CoS date and send. | New NHHDC. |
| Appendix 4.5 – Deemed Meter Advance Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier41. | Internal Process. |
|
|
|
|
| D0086 Notification of Change of Supplier Readings. Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier | Electronic or other method as agreed. |
|
| b) If invalid, produce and send an Invalid Data Report. Return to 3.2.6.30 or 3.2.6.31. | New NHHDC. | New Supplier, LDSO, Old NHHDC42, if applicable. | D0086 Notification of Change of Supplier Readings30. |
|
3.2.6.40 | Following 3.2.6.39 | Send change of Supplier Deemed Meter Reading | Old NHHDC | Old Supplier | D0086 Notification of Change of Supplier Readings | Electronic or other method as agreed. |
For DCC serviced SVA NHH Metering Systems24 | ||||||
3.2.6.41 | From SSD.43 | Old Supplier retrieves and checks the SSD midnight44 register reading(s). | Old Supplier. |
|
| Internal Process. |
3.2.6.42 | Within 1WD of 3.2.6.41 and by SSD+3WD | If SSD midnight register reading(s) retrieved Send the SSD midnight register reading(s).45 | Old Supplier. | New Supplier | D0010 Meter Readings. | Electronic or other method, as agreed. |
3.2.6.43 | From SSD43, 46 | New Supplier retrieves the SSD midnight44 register reading(s). The New Supplier will also take instantaneous readings, including the total cumulative register reading and all time of use register readings47. The readings should be synchronised with the successful reconfiguration of the Meter, where applicable. If the new Supplier is unable to configure the Meter until after the SSD, but is able to do so by SSD+5WD, for example due to a communications failure, the new Supplier will re-date any SSC change (and associated) readings to the SSD. If the new Supplier is unable to configure the Meter until after SSD+5 WD, the new Supplier will use the change of SSC process in 3.3.6 and will adopt the old Supplier’s SSC for the intervening period. | New Supplier. |
|
| Internal Process. |
3.2.6.44 | If the new Supplier has been unable to communicate with the smart Meter by SSD+5WD | Notify the new NHHDC that the process for non DCC serviced NHH Metering Systems should be followed. Proceed from 3.2.6.5. | New Supplier | New NHHDC | D0170 Request for Metering System Related Details | Electronic or other method, as agreed |
3.2.6.45 | If the new Supplier has been able to obtain a reading(s) and within 3 WD of 3.2.6.43. | Send reading(s) to new NHHDC and Old Supplier. The new Supplier will send the old Supplier all the instantaneous readings taken on configuration of the Meter under 3.2.6.43, including the total cumulative register reading and all 48 time of use register readings.48, 49, 50, 51 The new Supplier will send the new NHHDC the register readings associated with the Metering System’s (new) Standard Settlement Configuration / Time Pattern Regime(s). | New Supplier. | New NHHDC Old Supplier | D0010 Meter Readings. | Electronic or other method, as agreed. |
3.2.6.46 | Within 1 WD of 3.2.6.45 | The old Supplier will send the old NHHDC the reading(s) associated with the Metering System’s (old) Standard Settlement Configuration / Time Pattern Regime(s). The “Reading Type” will be flagged as “R – Routine”. If the old Supplier has been able to obtain a reading(s), but has not received readings from the new Supplier by SSD+10WD, the old Supplier will initiate the missing reads process earlier than the usual SSD+30 WD timescales, using the D0300 as per the REC. | Old Supplier | Old NHHDC | D0010 Meter Readings | Electronic or other method, as agreed |
3.2.6.47 | Within 3 WDs of 3.2.6.46 and in sufficient time to enable the reading to be included in the Initial Settlement Run relating to the last Settlement Day for which the old Supplier is responsible. | Validate Meter register reading(s) | Old NHHDC |
| Appendix 4.2 – Validate Meter Data, Appendix 4.4 – Change of Supplier Activities, Appendix 4.6 – Manual Adjustment of Meter Reading(s) | Internal process |
3.2.6.48 | If reading(s) valid and within 1 WD of 3.2.6.47 | Produce and send Valid Data Report | Old NHHDC | Old Supplier, LDSO | D0086 Notification of Change of Supplier Readings Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Electronic or other method, as agreed |
3.2.6.49 | If reading(s) invalid and within 1 WD of 3.2.6.47 | Produce and send Invalid Data Report It is unlikely that the old NHHDC will have cause to invalidate a reading from the smart meter. The old NHHDC should address register mapping issues with the help of the old Supplier. The old Supplier should address any issues with the readings received from the new Supplier with the new Supplier, using the disputed CoS readings process, as necessary. | Old NHHDC | Old Supplier, LDSO | D0010 Meter Readings | Electronic or other method, as agreed |
3.2.6.50 | Within 1 WD of the later of receipt of the MTD from Old SVA MOA (if concurrent change of SVA NHHMOA) or receipt (where applicable) of Configuration Details from the New Supplier. | Send the MTD to the new NHHDC, New Supplier and LDSO | New SVA MOA. | New NHHDC, New Supplier, LDSO | D0149 Notification of Mapping Details. D0150 Non-Half Hourly Meter Technical Details. | Electronic or other method, as agreed. |
3.2.6.51 | Within 1 WD of 3.2.6.50 | Send initial EAC (class average or, where provided by the Old Supplier, the latest EAC) for each Settlement Register associated with the SSC and the Profile Class. Send the date for which any change of SSC has been registered. (On change of SSC, the Supplier will also notify the SMRA using a D0205 Update Registration Details flow in accordance with BSCP501 3.3.1). | New Supplier. | New NHHDC. | D0052 Affirmation of Metering Settlement Details. See Appendix 4.12 – Usage and Validation of Affirmation of Metering System Settlement Details (D0052) Flow | Electronic or other method, as agreed. |
3.2.6.52 | Within 3WD of the later of 3.2.6.45, 3.2.6.50 and 3.2.6.51. | Select and validate the candidate CoS reading(s). Process and validate the Meter register reading, using the MTD provided by the SVA MOA (in 3.2.6.50). | New NHHDC |
| Appendix 4.2 - Validate Meter Data, Appendix 4.4 -Change of Supplier Activities, Appendix 4.6 – Manual Adjustment of Meter Reading(s). | Internal Process. |
3.2.6.53 | If invalid Meter register reading obtained. | Produce and send an Invalid Data Report.52 | New NHHDC. | New Supplier, LDSO. | D0010 Meter Readings.31 | Electronic or other method, as agreed. |
3.2.6.54 | If valid Meter register reading obtained. | Produce and send Valid Data Report. | New NHHDC. | New Supplier, LDSO. | D0086 Notification of Change of Supplier Readings.32 Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Electronic or other method, as agreed. |
3.2.6.55 | If the new NHHDC invalidates the candidate CoS reading(s).52 | The New Supplier will investigate the invalid read and agree the next steps with their NHHDC to obtain a valid reading. The New Supplier should initiate the disputed reads process if the result of the investigation is that the reading sent to the old Supplier in step 3.2.6.45 is now incorrect. | New Supplier. | New NHHDC |
| Electronic or other method as agreed |
3.2.6.56 | As applicable and within 1WD of 3.2.6.55. | Send resulting change of Supplier Meter Reading. | New NHHDC. | New Supplier, LDSO. | D0086 Notification of Change of Supplier Readings. | Electronic or other method as agreed |
3.2.6.57 | No later than 12 months after SSD, if the new Supplier wants to dispute the CoS reading prior to the Final Volume Allocation Run38. | Disagree reading and: a) Provide an actual or customer Meter register reading. |
New Supplier. |
Old Supplier39. |
D0300 Disputed Readings or Missing Readings on Change of Supplier39. |
Manual process. |
|
| b) Agree this Meter register reading with the old Supplier38. | New Supplier. | Old Supplier. | D0300 Disputed Readings or Missing Readings on Change of Supplier. |
|
|
| c) (i) Send the agreed Meter register reading to the new NHHDC; and/or | New Supplier. | New NHHDC. | D0300 Disputed Readings or Missing Readings on Change of Supplier. |
|
|
| (ii) Send the agreed Meter register reading to the old NHHDC. Refer to 3.2.6.58. | Old Supplier. | Old NHHDC. | D0300 Disputed Readings or Missing Readings on Change of Supplier. |
|
3.2.6.58 | No later than 12 months after SSD if the old Supplier wants to dispute the CoS reading prior to the Final Volume Allocation Run38. | Disagree reading and: a) Provide an actual or customer Meter register reading. |
Old Supplier. |
New Supplier39. |
D0300 Disputed Readings or Missing Readings on Change of Supplier39. |
Manual process. |
|
| b) Agree this Meter register reading with the new Supplier38. | Old Supplier. | New Supplier. | D0300 Disputed Readings or Missing Readings on Change of Supplier. |
|
|
| c) (i) Send the agreed Meter register reading to the old NHHDC; and/or | Old Supplier. | Old NHHDC. | D0300 Disputed Readings or Missing Readings on Change of Supplier. |
|
|
| (ii) Send the agreed Meter register reading to the new NHHDC. Refer to 3.2.6.59. | New Supplier. | New NHHDC. | D0300 Disputed Readings or Missing Readings on Change of Supplier. |
|
3.2.6.59 | When Meter register reading has been agreed between Suppliers and is outside previous timescales but in time for the Final Volume Allocation Run. | Process and validate Meter register reading. | Old NHHDC and/or New NHHDC as appropriate. |
| Appendix 4.2 - Validate Meter Data, Appendix 4.4 - Change of Supplier Activities; Appendix 4.6 – Manual Adjustment of Meter Reading(s). | Internal Process. |
|
| a) If valid, produce and send a Valid Data Report. Calculate a deemed Meter register reading39, 40 for the CoS date, if the agreed reading was not logged within five working days either side of the CoS date, and send. | Old NHHDC.
New NHHDC. | Old Supplier, LDSO. New Supplier, LDSO. | Appendix 4.5 – Deemed Meter Advance Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier41. | Internal Process. |
|
|
|
|
| D0086 Notification of Change of Supplier Readings. Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier | Electronic or other method as agreed. |
|
| b) If invalid, produce and send an Invalid Data Report. Return to 3.2.6.57 or 3.2.6.58 as applicable. | Old NHHDC.
New NHHDC. | Old Supplier, LDSO. New Supplier, LDSO. | D0086 Notification of Change of Supplier Readings30. |
|
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.2.7.1 |
| Send appointment details to the new NHHDC, including the details of the current Agents. | Supplier | New NHHDC
SMRA | D0155 Notification of Meter Operator or Data Collector Appointment and Terms D0148 Notification of Change to Other Parties D0052 Affirmation of Metering System Settlement Details D0302 Notification of Customer Details D0205 Update Registration Details | Electronic or other method, as agreed. |
3.2.7.2 | Once appointed to SVA MSID by Supplier. | Send the MTD to the new NHHDC. | SVA MOA. | New NHHDC. | D0149 Notification of Mapping Details. D0150 Non-Half Hourly Meter Technical Details. D0313 Auxiliary Meter Technical Details (in accordance with Appendix 4.20) | Electronic or other method, as agreed. |
3.2.7.3 | On date of change of LDSO | Where actual Meter register reading required: |
|
|
|
|
|
| Send request to obtain an actual Meter register reading. | Supplier. | Old NHHDC. | D0170 Request for Metering System Related Details | Electronic or other method, as agreed. |
|
| The old NHHDC will obtain a Meter register reading where instructed by the Supplier. Otherwise: | Old NHHDC. |
|
| Internal Process. |
|
| Retrieve a reading remotely, or if an appropriate Customer own reading has been received, provide this. | Supplier. | Old NHHDC. |
|
|
|
| The SVA MOA may send a Meter register reading to the old NHHDC. | SVA MOA. | Old NHHDC. | D0010 Meter Readings. | Electronic or other method, as agreed. |
3.2.7.4 | Following date of change of LDSO | Select the final reading for old MSID53. Process and validate the Meter register reading. | Old NHHDC. |
| Appendix 4.2 - Validate Meter Data, Appendix 4.6 – Manual Adjustment of Meter Reading(s). | Internal Process. |
3.2.7.5 | If invalid Meter register reading | Produce and send an Invalid Data Report. | Old NHHDC. | Supplier, old LDSO. |
| Electronic or other method, as agreed. |
3.2.7.6 | On receipt of Invalid Data Report. | Send a request to the old NHHDC to provide a Meter register reading to replace the invalid one already received. | Supplier. | Old NHHDC. |
| Electronic or other method, as agreed. |
3.2.7.7 | Following 3.2.7.6 | The old NHHDC will collect a Meter register reading, based on the request from the Supplier. Return to 3.2.7.4 | Old NHHDC. |
|
| Internal Process. |
3.2.7.8 | If valid Meter register reading obtained for date of change of LDSO | Produce and send Valid Data Report. | Old NHHDC. | Supplier, old LDSO. | D0010 Meter Readings. Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Electronic or other method, as agreed. |
3.2.7.9 | If valid Meter register reading not obtained for date of Change of LDSO | Calculate a final Deemed Meter Reading for the old MSID | Old NHHDC. |
| Appendix 4.5 – Deemed Meter Advance | Internal Process. |
|
| Send this Deemed Meter Reading. | Old NHHDC. | Supplier, old LDSO. | D0010 Meter Readings Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Electronic or other method, as agreed. |
3.2.7.10 | Within 10 WD of 3.2.7.9 | Send final Meter register reading (whether actual or deemed) for old MSID. This shall be used as the initial Meter reading for the new MSID. | Old NHHDC | New NHHDC | D0010 Meter Readings | Electronic or other method, as agreed |
3.2.7.11 | Once final Meter reading for Old MSID received | Send this Meter reading | New NHHDC | New LDSO | D0010 Meter Readings | Electronic or other method, as agreed |
3.2.7.12 | If no Meter reading provided by 10 WD after change of LDSO | Request final Meter reading for old MSID. | New NHHDC | Old NHHDC, Supplier |
| Post / Fax / Email |
3.2.7.13 | Following 3.2.7.12 | Send final Meter reading for old MSID. This shall be used as the initial Meter reading for the new MSID. | Old NHHDC, Supplier | New NHHDC | D0010 Meter Readings | Electronic or other method, as agreed |
3.2.7.14 | Once final Meter reading for Old MSID received | Send this Meter reading | New NHHDC | New LDSO | D0010 Meter Readings | Electronic or other method, as agreed |
3.2.7.15 | At least 10 WD after 3.2.7.12 and no more than 12 months after 3.2.7.12, if no final Meter reading has been received for old MSID | Obtain Meter register reading, deem initial Meter reading in accordance with Appendix 4.5 and calculate associated EAC / AA(s) | New NHHDC |
| Appendix 4.5 – Deemed Meter Advance Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Internal Process |
3.2.7.16 | Once Deemed Meter Reading has been calculated | Send this Deemed Meter Reading. | New NHHDC. | Supplier, new LDSO, Old NHHDC | D0010 Meter Readings Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Electronic or other method, as agreed |
3.2.7.17 | Following 3.2.7.16 | Send Deemed Meter Reading | Old NHHDC | Old LDSO | D0010 Meter Readings | Electronic or other method as agreed. |
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.2.8.1 | By New Supplier SSD | Send appointment. The Supplier will notify the new NHHDC if the Metering System has a DCC serviced smart Meter. | New Supplier. | New NHHDC. | D0155 Notification of New Meter Operator or Data Collector Appointment and Terms. | Electronic or other method, as agreed. |
3.2.8.2 | If appointment rejected and within 2 WD of 3.2.8.1 | Send notification of rejection of appointment including the reason why the request has been rejected. | New NHHDC | New Supplier | D0261 Rejection of Agent Appointment. Go to 3.2.8.1 if required | Electronic or other method, as agreed. |
3.2.8.3 | If appointment accepted and within 2 WD of 3.2.8.1 | The new NHHDC will confirm appointment with the new Supplier. | New NHHDC. | New Supplier. | D0011 Agreement of Contractual Terms. | Electronic or other method, as agreed. |
3.2.8.4 | On appointment of SVA NHHMOA and within 1 WD of 3.2.8.354 | Send notification of old NHHDC, new NHHDA and new SVA NHHMOA (as applicable).
| New Supplier | New NHHDC | D0148 Notification of Change to Other Parties. | Electronic or other method, as agreed. |
3.2.8.5 | As required and within 1 WD of 3.2.8.4 and once registration notification received. | Send request to old NHHDC to send Meter register reading and associated EAC. | New NHHDC. | Old NHHDC. | D0170 Request for Metering System Related Details. | Electronic or other method, as agreed. |
3.2.8.6 | If applicable (i.e. to the extent that that the relevant data is available for a removed Meter) and within 2 WD of 3.2.8.5 provided an EAC has been calculated for latest valid reading or within 1 WD of EAC being calculated for latest valid reading if an EAC has yet to be calculated55. | Send Meter register reading and associated EAC. In addition, if the old NHHDC obtains an actual or a customer Meter register reading before the SSD, then ensure this reading(s) will be validated and processed prior to it being sent to the new NHHDC. Send the revised Meter register reading history to the new NHHDC.56 | Old NHHDC. | New NHHDC. | Appendix 4.8 – Historical Data Requirements. D0010 Meter Readings. D0152 Metering System EAC/AA Historical Data. | Electronic or other method, as agreed. |
3.2.8.7 | Within 1 WD of receipt of the D0148 (if no concurrent change of SVA NHHMOA) or within 1 WD of receipt of MTD from Old SVA NHHMOA (if concurrent change of SVA NHHMOA). | Send the MTD to the new NHHDC. | New SVA NHHMOA. | New NHHDC. | D0150 Non-Half Hourly Meter Technical Details. | Electronic or other method, as agreed. |
3.2.8.8 | Where the Supplier ceases to be responsible at the same time as the NHHDC is also ceasing to trade | Prepare and maintain plans that will enable the Panel to fulfil the obligations of the Supplier under the Code. | Old NHHDC | Panel | Plans should detail how the NHHDC will upon termination or expiry; make arrangements for the immediate transfer of data and other information to the Panel. | Electronic or other method, as agreed. |
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.3.1.1 | Prior to CoMC date change. | Send notification of termination of appointment. | Old Supplier59. | NHHDC. | D0151 Termination of Appointment or Contract by Supplier. The old NHHDC becomes de-appointed on SSD-1. | Electronic or other method, as agreed. |
3.3.1.2 | By SSD+5. | Send final Meter register reading(s) or notification that Meter register reading not obtainable and notification that this is a coincident CoS. | SVA NHHMOA. | NHHDC. | D0010 Meter Readings or D0002 Fault Resolution Report or Request for Decision on Further Action (use the “Additional Information” field to indicate that this is a coincident change). | Electronic or other method, as agreed. |
|
| Notification of Meter removal (or that Meter is no longer NHH) |
|
| D0150 Non-Half Hourly Meter Technical Details. |
|
3.3.1.3 | By SSD+8. | If Meter register reading(s) obtained, validate Meter register reading(s). | Current NHHDC. |
| Appendix 4.2 - Validate Meter Data, Appendix 4.6 – Manual Adjustment of Meter Reading(s). | Internal Process. |
3.3.1.4 | By SSD+8. | If valid Meter register reading(s), produce and send Valid Data Report. | Current NHHDC. | Old Supplier60, LDSO. | D0086 Notification of Change of Supplier Readings. Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Electronic or other method, as agreed. |
3.3.1.5 | By SSD+8. | If invalid Meter register reading(s), produce and send Invalid Data Report. | Current NHHDC. | Old Supplier, LDSO. | D0010 Meter Readings. | Electronic or other method, as agreed. |
3.3.1.6 | If concurrent CoS and CoMC and Meter register reading invalid or not received by SSD+8. | Calculate deemed reading(s) and associated EAC/AA(s). | Current NHHDC. |
| Appendix 4.5 – Deemed Meter Advance Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Internal Process. |
3.3.1.7 | By SSD+8. | Send Deemed Meter Reading(s). | Current NHHDC. | Old Supplier, LDSO. | D0086 Notification of Change of Supplier Readings. Refer to section 3.3.11 Calculate AA/EAC and send to NHHDA and Supplier. | Electronic or other method, as agreed. |
3.3.1.8 | If CoMC only, and no Meter register reading received by 15 WD after the CoMC and if required. | Request final Meter register reading | Current NHHDC | SVA MOA, Old Supplier |
| Post / Fax / Email |
3.3.1.9 | Within 10 WD of 3.3.1.8 | Send final Meter register reading | SVA NHH MOA / Old Supplier | Current NHHDC12 | D0010 Meter Readings | Electronic or other method, as agreed |
3.3.1.10 | If required and no valid Meter register reading received within 10 WD of 3.3.1.9 | Deem final Meter register reading and calculate associated EAC / AA(s) | Current NHHDC |
| Appendix 4.5 – Deemed Meter Advance Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Internal Process |
3.3.1.11 | Following 3.3.1.10 | Send Deemed final Meter Reading | Current NHHDC | Old Supplier, LDSO | D0010 Meter Readings | Electronic or other method as agreed |
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.3.2.1 | By SSD – 1 WD | Send notification to NHHDC of appointment to NHH SVA MS. Also send details of the NHHDA and SVA NHHMOA for the SVA MS to the NHHDC. | New Supplier. | NHHDC. | D0148 Notification of Change to Other Parties. D0155 Notification of new Meter Operator or Data Collector Appointment and Terms. D0302 Notification of Customer Details | Electronic or other method, as agreed. |
3.3.2.2 | Within 10 WD of installation of Metering system. | Send MTD. | SVA NHH MOA | New Supplier, NHHDC, LDSO. | D0149 Notification of Mapping Details. D0150 Non-Half Hourly Meter Technical Details. | Electronic or other method, as agreed. |
|
|
|
| NHHDC New Supplier | D0313 Auxiliary Meter Technical Details (in accordance with Appendix 4.20) |
|
|
| Send initial Meter register reading |
| NHHDC | D0010 Meter Readings. |
|
3.3.2.3 | Within 5 WD of receipt of D0150 from the SVA NHHMOA | Send notification of SVA Metering System details, including initial (class average) EAC to the NHHDC. | Supplier. | NHHDC. SMRA | D0052 Affirmation of Metering System Settlement Details. D0205 Update Registration Details See Appendix 4.12 – Usage and Validation of Affirmation of Metering System Settlement Details (D0052) Flow | Electronic or other method, as agreed. |
3.3.2.4 | On receipt of D0052 and D0150 | Validate D0052. Check for discrepancies between the Metering System Settlement Details provided by the Supplier and the Meter Technical Details provided by the SVA NHHMOA. | NHHDC |
| See Appendix 4.12 – Usage and Validation of Affirmation of Metering System Settlement Details (D0052) Flow | Internal |
3.3.2.5 | If D0052 invalid | Send notification of invalid Metering System Settlement details to Supplier | NHHDC | Supplier | D0310 Notification of Failure to Load or Receive Metering System Settlement Details12 | Electronic or other method, as agreed. |
3.3.2.6 | On receipt of D0310 | Supplier should resolve the problem by re-sending or revising the D0052 as required or by instructing the SVA NHHMOA to re-send the D0150. | Supplier | NHHDC SMRA | D0052 Affirmation of Metering System Settlement Details. D0205 Update Registration Details As required | Electronic or other method, as agreed. |
3.3.2.7 | On receipt of valid D0052 | Send the initial (class average) EAC for each Settlement register of the SVA MS to the NHHDA. Process EAC/AA data in accordance with section 3.5. | NHHDC. | NHHDA. | D0019 Metering System EAC/AA Data. | Electronic or other method, as agreed. |
3.3.2.8 |
| Process and validate Meter register reading. | NHHDC. |
| Appendix 4.2 – Validate Meter Data, Appendix 4.6 – Manual Adjustment of Meter Reading(s). | Internal Process. |
3.3.2.9 | If invalid Meter register reading. | Produce and send Invalid Data Report. | NHHDC. | LDSO, Supplier. | D0010 Meter Readings. | Electronic or other method, as agreed. |
3.3.2.10 | If valid Meter register reading. | Produce and send Valid Data Report. | NHHDC. | LDSO, Supplier. | D0010 Meter Readings. Refer to section 3.3.11 Calculate AA/EAC and send to NHHDA and Supplier. | Electronic or other method, as agreed. |
3.3.2.11 | If no Meter register reading received within 10 WD of CoMC and initial reading required61 | Request initial Meter register reading | NHHDC | SVA NHH MOA, Supplier, Old HHDC (where possible and if same Metering Equipment is in use) |
| Post / Fax / Email |
3.3.2.12 | Within 10 WD of receipt of request for initial Meter Register reading | Send initial Meter register reading | SVA NHH MOA, Supplier, Old HHDC | NHHDC12 | D0010 Meter Readings | Electronic or other method, as agreed |
3.3.2.13 | If required and at least 10 WD after 3.3.2.11 and no more than 1262 months after 3.3.2.11, if no initial valid Meter register reading has been received | Deem initial Meter reading in accordance with Appendix 4.5 and calculate associated EAC / AA(s) | NHHDC |
| Appendix 4.5 – Deemed Meter Advance Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Internal Process |
3.3.2.14 | Following 3.3.2.13 | Send Deemed Meter Reading | NHHDC | Supplier, LDSO | D0010 Meter Readings | Electronic or other method as agreed |
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.3.3.1 | Within 10 WD of attempting to change energisation status. | Send change of energisation status and initial Meter register reading. | SVA MOA SVA MOA | NHHDC, NHHDC, Supplier, LDSO | D0139 Confirmation or Rejection of Energisation Status Change. D0010 Meter Readings | Electronic or other method, as agreed. |
3.3.3.2 | On receipt of notification of change of energisation status. | Process and validate Meter register readings63. During processing, if communications equipment disconnected, record this as well as the source of the notification of the energisation. | NHHDC. |
| Appendix 4.2 - Validate Meter Data, Appendix 4.6 – Manual Adjustment of Meter Reading(s). | Internal Process. |
3.3.3.3 | If invalid Meter register reading. | Produce and send Invalid Data Report. | NHHDC. | Supplier, LDSO. | D0010 Meter Readings. | Electronic or other method, as agreed. |
3.3.3.4 | If valid Meter register reading. | Produce and send Valid Data Report. | NHHDC. | Supplier, LDSO. | D0010 Meter Readings. Refer to section 3.3.11 - Calculate AA/EAC Values and send to NHHDA and Supplier. | Electronic or other method, as agreed. |
3.3.3.5 | If required and no valid Meter register reading received within 10 WD of notification of change to energisation status | Request initial Meter register reading | NHHDC | SVA MOA, Supplier |
| Post / Fax / Email |
3.3.3.6 | Within 10 WD of 3.3.3.5 | Send initial Meter register reading | SVA MOA / Supplier | NHHDC13 | D0010 Meter Readings | Electronic or other method, as agreed |
3.3.3.7 | 10 WD after 3.3.3.5, if no valid Meter register reading received | If available substitute final Meter reading taken when the Metering System was de-energised for the initial Meter reading and calculate associated EAC / AA(s). | NHHDC |
| Appendix 4.5 – Deemed Meter Advance Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Internal Process |
3.3.3.8 | If required and at least 10 WD after 3.3.3.5 and by 10 WD before the Final Reconciliation Run for the relevant Settlement Date, if no valid initial Meter register reading has been received | Deem initial Meter reading in accordance with Appendix 4.5 and calculate associated EAC / AA(s) | NHHDC |
| Appendix 4.5 – Deemed Meter Advance Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Internal Process |
3.3.3.9 | Following 3.3.3.8 | Send Deemed Meter Reading | NHHDC | Supplier, LDSO | D0010 Meter Readings | Electronic or other method as agreed |
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.3.4.1 | Within 10 WD of attempting to change energisation status. | Send change of energisation status and final Meter register reading. | SVA MOA. SVA MOA | NHHDC, Supplier. LDSO. NHHDC, | D0139 Confirmation or Rejection of Energisation Status Change. D0010 Meter Readings | Electronic or other method, as agreed. |
3.3.4.2 | If Meter register reading received. | Process and validate Meter register reading. During processing, if communications equipment disconnected, record this as well as the source of the notification of the de-energisation. | NHHDC. |
| Appendix 4.2 - Validate Meter Data, Appendix 4.6 – Manual Adjustment of Meter Reading(s). | Internal Process. |
3.3.4.3 | If invalid Meter register reading received. | Produce and send Invalid Data Report. | NHHDC. | Supplier, LDSO. | D0010 Meter Readings. | Electronic or other method, as agreed. |
3.3.4.4 | If valid Meter register reading received. | Produce and send Valid Data Report. | NHHDC. | Supplier, LDSO. | D0010 Meter Readings. Refer to section 3.3.11 - Calculate AA/EAC Values and send to NHHDA and Supplier. | Electronic or other method, as agreed. |
3.3.4.5 | If required and no valid Meter register reading received within 10 WD of notification of change to energisation status | Request final Meter register reading | NHHDC | SVA MOA, Supplier |
| Post / Fax / Email |
3.3.4.6 | Within 10 WD of 3.3.4.5 | Send final Meter register reading | SVA MOA / Supplier | NHHDC12 | D0010 Meter Readings | Electronic or other method, as agreed |
3.3.4.7 | If required and no valid Meter register reading received within 10 WD of 3.3.4.5 | Deem final Meter register reading and calculate associated EAC / AA(s)64 | NHHDC |
| Appendix 4.5 – Deemed Meter Advance Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Internal Process |
3.3.4.8 | Following 3.3.4.7 | Send Deemed Meter Reading | NHHDC | Supplier, LDSO | D0010 Meter Readings | Electronic or other method as agreed |
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.3.5.1 | As appropriate | Send change of energisation status and final Meter register reading. | SVA MOA. | NHHDC. | D0139 Confirmation or Rejection of Energisation Status Change. | Electronic or other method, as agreed. |
3.3.5.2 | If Meter register reading obtained. | Process and validate Meter register reading. During processing, if communications equipment disconnected record this as well as the notification of termination of the appointment to the SVA MS from the Supplier. | NHHDC. |
| Appendix 4.2 - Validate Meter Data, Appendix 4.6 – Manual Adjustment of Meter Reading(s). | Internal Process. |
3.3.5.3 | If invalid Meter register reading. | Produce and send Invalid Data Report. | NHHDC. | Supplier, LDSO. | D0010 Meter Readings. | Electronic or other method, as agreed. |
3.3.5.4 | If valid Meter register reading. | Produce and send Valid Data Report. | NHHDC. | Supplier, LDSO. | D0010 Meter Readings. Refer to section 3.3.11 - Calculate AA/EAC Values and send to NHHDA and Supplier. | Electronic or other method, as agreed. |
3.3.5.5 | If required and no valid Meter register reading received within 10 WD of the disconnection | Request final Meter register reading | NHHDC | SVA MOA, Supplier |
| Post / Fax / Email |
3.3.5.6 | Within 10 WD of 3.3.5.5 | Send final Meter register reading | SVA MOA / Supplier | NHHDC12 | D0010 Meter Readings | Electronic or other method, as agreed |
3.3.5.7 | If required and no valid Meter register reading received within 10 WD of 3.3.5.5 or notification received that the reading is unavailable | If available, substitute the de-energisation reading as the disconnection reading. If not available, deem the final Meter register reading Calculate associated EAC / AA(s) | NHHDC |
| Appendix 4.5 – Deemed Meter Advance Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Internal Process |
3.3.5.8 | Following 3.3.5.7 | Send Deemed Meter Reading | NHHDC | Supplier, LDSO | D0010 Meter Readings | Electronic or other method as agreed |
3.3.5.9 | On confirmation from CSS of registration deactivation | Send appointment end details to NHHDC. | Supplier. | NHHDC. | D0151 Termination of Appointment or Contract by Supplier. | Electronic or other method, as agreed. |
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.3.6.1 |
| Send notification that Meter registers are to be reprogrammed. If necessary, agree revised contractual terms with NHHDC. | Supplier65 | NHHDC. | P0027 Notification of Pending Work. | Electronic or other method, as agreed. |
For NHH Meters other than Smart Meters | ||||||
3.3.6.2 |
| Pass final Meter register reading for old register configuration and initial Meter register reading for new register configuration, including MTD and the mapping of these onto each Settlement Register66. | SVA MOA. | NHHDC. | D0010 Meter Readings. | Electronic or other method, as agreed. |
|
|
|
| NHHDC, Supplier, LDSO. | D0149 Notification of Mapping Details. D0150 Non-Half Hourly Meter Technical Details. |
|
|
|
|
| NHHDC Supplier | D0313 Auxiliary Meter Technical Details (in accordance with Appendix 4.20) |
|
For smart Meters | ||||||
3.3.6.3 | Within 10WD of reconfiguration | Pass new MTDs. | SVA MOA | NHHDC / LDSO | D0149 Notification of Mapping Details. D0150 Non-Half Hourly Meter Technical Details. | Electronic or other method, as agreed. |
3.3.6.4 | Within 10WD of reconfiguration | Pass final Meter register reading(s) for old register configuration and initial Meter register reading(s) for new register configuration | Supplier | NHHDC | D0010 Meter Readings |
|
For all Meters | ||||||
3.3.6.5 | Within 5 WD of receipt of D0150 from the SVA MOA | Send initial (class average) EAC for each Settlement Register associated with the new SSC and the new Profile Class67 (where appropriate). Send the date for which any change of SSC has been registered. | Supplier | NHHDC SMRA | D0052 Affirmation of Metering Settlement Details. D0205 Update Registration Details See Appendix 4.12 – Usage and Validation of Affirmation of Metering System Settlement Details (D0052) Flow | Electronic or other method, as agreed. |
3.3.6.6 | On receipt of D0052 and D0150 | Validate D0052. Check for discrepancies between the Metering System Settlement Details provided by the Supplier and the Meter Technical Details provided by the SVA MOA. | NHHDC |
| See Appendix 4.12 – Usage and Validation of Affirmation of Metering System Settlement Details (D0052) Flow. | Internal |
3.3.6.7 | If D0052 invalid | Send notification of invalid Metering System Settlement details to Supplier | NHHDC | Supplier | D0310 Notification of Failure to Load or Receive Metering System Settlement Details12 | Electronic or other method, as agreed. |
3.3.6.8 | On receipt of D0310 | Supplier should resolve the problem by re-sending or revising the D0052 as required or by instructing the SVA MOA to re-send the D0150. | Supplier | NHHDC, SMRA | D0052 Affirmation of Metering System Settlement Details. D0205 Update Registration Details As required | Electronic or other method, as agreed. |
3.3.6.9 | On receipt of valid D0052 | Send the initial (class average) EAC for each Settlement register of the SVA MS to the NHHDA. Process EAC/AA data in accordance with section 3.5. | NHHDC. | NHHDA. | D0019 Metering System EAC/AA Data. | Electronic or other method, as agreed. |
3.3.6.10 |
| Process and validate Meter register readings. | NHHDC. |
| Appendix 4.2 - Validate Meter Data, Appendix 4.6 – Manual Adjustment of Meter Reading(s). | Internal Process. |
3.3.6.11 | If invalid Meter register reading. | Produce and send Invalid Data Report. | NHHDC. | Supplier, LDSO. | D0010 Meter Readings. Refer to section 3.3.11 - Calculate AA/EAC Values and send to NHHDA and Supplier. | Electronic or other method, as agreed. |
3.3.6.12 | If valid Meter register reading. | Produce and send Valid Data Report. | NHHDC. | Supplier, LDSO. | D0010 Meter Readings. Refer to section 3.3.11 Calculate AA/EAC and send to NHHDA and Supplier. | Electronic or other method, as agreed. |
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
For NHH Meters other than smart Meters | ||||||
3.3.7.1 | Within 10 WD of replacing / reconfiguring MS | Send final Meter register reading for replaced / reconfigured MS or notify that Meter register reading not obtainable. Send Meter register reading for replacement MS / new configuration. Send MTD for replacement MS / new configuration. | NHHDC. | D0010 Meter Readings or D0002 Fault Resolution Report or Request for Decision on Further Action | Electronic or other method, as agreed. | |
|
|
| NHHDC, Supplier, LDSO. |
| D0149 Notification of Mapping Details D0150 Non-Half Hourly Meter Technical Details. |
|
|
|
| NHHDC, Supplier |
| D0313 Auxiliary Meter Technical Details (in accordance with Appendix 4.20) |
|
For smart Meters | ||||||
3.3.7.2 | Within 10WD of Meter replacement | Send new MTDs. | SVA MOA. | NHHDC / LDSO | D0149 Notification of Mapping Details D0150 Non-Half Hourly Meter Technical Details. | Electronic or other method, as agreed. |
3.3.7.3 | Within 10WD of Meter replacement | Send final Meter register reading(s) for replaced Metering System (if smart) or notify that Meter register reading(s) not obtainable. | Supplier | NHHDC | D0010 Meter Readings D0002 Fault Resolution Report or Request for Decision on Further Action | Electronic or other method, as agreed. |
|
| Send Meter register reading for replacement MS. | Supplier | NHHDC | D0010 Meter Readings |
|
3.3.7.4 | Within 10WD of Meter reconfiguration | Send MTDs. | SVA MOA | NHHDC / LDSO | D0149 Notification of Mapping Details D0150 Non-Half Hourly Meter Technical Details. | Electronic or other method, as agreed. |
3.3.7.5 | Within 10WD of Meter reconfiguration | Send final Meter register reading(s) for reconfigured Metering System or notify that Meter register reading(s) not obtainable. | Supplier | NHHDC | D0010 Meter Readings D0002 Fault Resolution Report or Request for Decision on Further Action |
|
|
| Send Meter register reading for new configuration. | Supplier | NHHDC | D0010 Meter Readings |
|
For all Meters | ||||||
3.3.7.6 | If Meter register reading obtained from replaced / reconfigured MS. | Process and validate Meter register reading(s). | NHHDC. |
| Appendix 4.2 – Validate Meter Data, Appendix 4.6 – Manual Adjustment of Meter Reading(s). | Internal Process. |
3.3.7.7 | If invalid Meter register reading. | Produce and send Invalid Data Report. | NHHDC. | Supplier, LDSO. | D0010 Meter Readings. | Electronic or other method, as agreed. |
3.3.7.8 | If valid Meter register reading. | Produce and send Valid Data Report. | NHHDC. | Supplier, LDSO. | D0010 Meter Readings. Refer to section 3.3.11 – Calculate AA/EAC Values and send to NHHDA and Supplier. | Electronic or other method, as agreed. |
3.3.7.9 | If no valid Meter register reading(s) received within 10 WD of the replacement / reconfiguration and initial and / or final reading required | Request initial and / or final Meter register reading (for non-smart Meters) | NHHDC | SVA MOA, Supplier |
| Post / Fax / Email |
|
| Request initial and / or final Meter register reading (for smart Meters) | NHHDC | Supplier |
|
|
3.3.7.10 | Within 10 WD of 3.3.7.9 | Send initial and / or final Meter register reading | SVA MOA / Supplier | NHHDC12 | D0010 Meter Readings | Electronic or other method, as agreed |
3.3.7.11 | If required and no valid final Meter register reading received within 10 WD of 3.3.7.10 | Deem final Meter register reading and calculate associated EAC / AA(s) | NHHDC |
| Appendix 4.5 – Deemed Meter Advance Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Internal Process |
3.3.7.12 | If required and at least 10 WD after 3.3.7.8 and by 10 WD before the Final Reconciliation Run for the relevant Settlement Date, if no valid initial Meter register reading has been received | Deem initial Meter reading in accordance with Appendix 4.5 and calculate associated EAC / AA(s) | NHHDC |
| Appendix 4.5 – Deemed Meter Advance Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Internal Process |
3.3.7.13 | Following 3.3.7.12 | Send Deemed Meter Reading | NHHDC | Supplier, LDSO | D0010 Meter Readings | Electronic or other method as agreed |
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.3.8.1.1 | As soon as possible after SVA MS fault rectified. | Send:
Meter register reading following rectification of fault (to be used for subsequent MAP). | SVA MOA. | D0002 Fault Resolution Report or Request for Decision on Further Action. D0010 Meter Readings (if applicable). P0192 Invalid Meter Reading / AA / EAC. | Electronic or other method, as agreed. | |
3.3.8.1.2 | By 5 WD after 3.3.8.1.1. | Determine which Meter register reading(s) / AA/EAC(s) affected by the period of the fault. Withdraw the Meter register reading(s) (back to the last valid Meter register reading which was obtained prior to the period of the fault) and the AA/EAC(s) (relating to the period of the fault). Complete a Site Visit Report. | NHHDC. |
| Appendix 4.1 - Site Checks of SVA Metering System - Site Visit Report. Appendix 4.3 - Withdrawing Meter Reading(s) / AA/EAC(s). | Internal Process. |
3.3.8.1.3 | By 1 WD after 3.3.8.1.2. | Send notification:
|
NHHDC.
NHHDC. |
Supplier, LDSO.74 Supplier, NHHDA. |
D0010 Meter Readings. D0019 Metering System EAC/AA Data. | Electronic or other method, as agreed. |
3.3.8.1.4 | If required and no valid final Meter register reading received 5 WD after SVA MS fault rectified | Deem final Meter register reading and calculate associated EAC / AA(s) | NHHDC |
| Appendix 4.5 – Deemed Meter Advance Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Internal Process |
3.3.8.1.5 | Following 3.3.8.1.4 | Send Deemed Meter Reading | NHHDC | Supplier, LDSO | D0010 Meter Readings | Electronic or other method as agreed |
3.3.8.1.6 | If required and no valid initial Meter register reading received 5 WD after SVA MS fault rectified | Request initial Meter register reading | NHHDC | SVA MOA, Supplier |
| Post / Fax / Email |
3.3.8.1.7 | Within 10 WD of 3.3.8.1.6 | Send initial Meter register reading | SVA MOA / Supplier | NHHDC12 | D0010 Meter Readings | Electronic or other method, as agreed |
3.3.8.1.8 | If required and at least 10 WD after 3.3.8.1.6 and by 10 WD before the Final Reconciliation Run for the relevant Settlement Date, if no valid initial Meter register reading has been received | Deem initial Meter reading in accordance with Appendix 4.5 and calculate associated EAC / AA(s) | NHHDC |
| Appendix 4.5 – Deemed Meter Advance Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Internal Process |
3.3.8.1.9 | Following 3.3.8.1.8 | Send Deemed Meter Reading | NHHDC | Supplier, LDSO | D0010 Meter Readings | Electronic or other method as agreed |
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.3.8.2.1 | As soon as possible after installation of new SVA MS. | Send:
| SVA MOA. | NHHDC76 73. | D0002 Fault Resolution Report or Request for Decision on Further Action. D0010 Meter Readings. D0149 Notification of Mapping Details. D0150 Non-Half Hourly Meter Technical Details. D0313 Auxiliary Meter Technical Details (in accordance with Appendix 4.20) | Electronic or other method, as agreed. |
|
| If there is a change of SSC as a result of installing new SVA MS, send the revised SVA MS details and the initial (class average) EAC. | Supplier. | NHHDC SMRA | D0052 Affirmation of Metering System Settlement Details. D0205 Update Registration Details |
|
|
| Send final Meter register reading for removed smart SVA MS where obtained remotely. | Supplier | NHHDC | D0010 Meter Readings |
|
3.3.8.2.2 | If there is a change of SSC. | Validate D0052. Check for discrepancies between the Metering System Settlement Details provided by the Supplier and the Meter Technical Details provided by the SVA MOA. Notify Supplier of any exceptions in accordance with 3.3.6.9 to 3.3.6.11. | NHHDC | Supplier | See Appendix 4.12 – Usage and Validation of Affirmation of Metering System Settlement Details (D0052) Flow. D0310 Notification of Failure to Load or Receive Metering System Settlement Details11. | Electronic or other method, as agreed. |
3.3.8.2.3 | By 1 WD after 3.3.8.2.1. | Process and validate Meter register reading(s) for replacement SVA MS. | NHHDC. |
| Appendix 4.2 - Validate Meter Data, Appendix 4.6 - Manual Adjustment of Meter Reading(s). | Internal Process. |
3.3.8.2.4 | By 1 WD after 3.3.8.2.3. | If invalid Meter register reading, produce and send Invalid Data Report for replacement SVA MS. If invalid Meter register reading then obtain alternative Meter register reading and return to 3.3.8.2.2. |
|
|
|
|
| NHHDC. | Supplier, LDSO. | D0010 Meter Readings. | Electronic or other method, as agreed. |
|
|
3.3.8.2.5 | By 1 WD after 3.3.8.2.3. | If valid Meter register reading, produce and send Valid Data Report for replacement SVA MS. | NHHDC. | Supplier, LDSO. | D0010 Meter Readings. | Electronic or other method, as agreed. |
3.3.8.2.6 | By 1 WD after 3.3.8.2.5. | For the removed SVA MS:
Complete a Site Visit Report (if applicable).. | NHHDC. |
| Appendix 4.1 - Site Checks of SVA Metering System - Site Visit Report. Appendix 4.3 - Withdrawing Meter Reading(s) / AA/EAC(s). | Internal Process. |
|
| For the replacement SVA MS:
|
|
|
|
|
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.3.8.3.1 | As soon as possible following identification of invalid Meter register reading(s) / AA(s). | Send notification that Meter register reading(s) / AA(s) invalid. | Supplier. | NHHDC. | P0192 Invalid Meter Reading / AA / EAC. D0010 Meter Readings (if applicable). | Manual Process. |
3.3.8.3.2 | By 5 WD after 3.3.8.3.1. | Determine whether Meter register reading(s) previously identified as valid is now invalid and / or determine whether AA previously identified as valid is now invalid in accordance with Appendix 4.9. Where appropriate in accordance with Appendix 4.9, withdraw the Meter register reading(s) and / or the AA/EAC(s). | NHHDC. |
| Appendix 4.1 - Site Checks of SVA Metering System - Site Visit Report. Appendix 4.9 - EAC/AA Calculation. | Internal Process. |
3.3.8.3.3 | By 1 WD after 3.3.8.3.2 | Send notification that Meter register reading(s) /AA/EAC(s) has been withdrawn. | NHHDC. | Supplier, LDSO77. | D0010 Meter Readings. | Electronic or other method, as agreed. |
3.3.8.3.4 | By 1 WD after 3.3.8.3.3. | Send the AA/EAC (in accordance with Appendix 4.9). Process EAC/AA data in accordance with section 3.5. | NHHDC.
NHHDA. | Supplier, NHHDA. | D0019 Metering System EAC/AA Data. If Gross Volume Correction is required, refer to section 3.4.4 | Electronic or other method, as agreed. |
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.3.8.4.1 | If actual Meter register reading(s) taken at the end of a Long Term Vacant period indicates that the deemed initial Meter79 reading(s) for the Long Term Vacant Period was incorrect. | Send notification that the deemed initial Meter register reading(s) at the start of the Long Term Vacant period is incorrect. Instruct whether or not to replace the withdrawn reading with the reading taken at the end of the Long Term Vacant Period, in accordance with Appendix 4.5. | Supplier. | NHHDC. | Details of the Meter register reading(s) to be withdrawn. Appendix 4.5 – Deemed Meter Advance. Reason for withdrawing the Meter register reading(s) | Manual Process. |
3.3.8.4.2 | By 5 WD after 3.3.8.4.1. | Withdraw the Meter register reading(s) and the associated EAC/AA(s). If last Meter reading was prior to RF, deem a Meter reading at RF in accordance with Appendix 4.5. If required enter the Meter reading taken at the end of the Long Term Vacant Period as the reading for the start of the Long Term Vacant Period in accordance with Appendix 4.5. | NHHDC. |
| Appendix 4.5 – Deemed Meter Advance. | Internal Process. |
3.3.8.4.3 | By 1 WD after 3.3.8.4.2 | Send notification that Meter register reading(s) /EAC/AA(s) has been withdrawn. | NHHDC. | Supplier, LDSO. | D0010 Meter Readings. | Electronic or other method, as agreed. |
3.3.8.4.4 | If appropriate, and by 1 WD after 3.3.8.4.2 | Send notification that the Meter register reading taken at the end of the Long Term Vacant Period is being used as the Meter reading at the start of the Long Term Vacant Period. | NHHDC | Supplier, LDSO | D0010 Meter Readings. | Electronic or other method as agreed. |
3.3.8.4.5 | By 1 WD after 3.3.8.4.3 and 3.3.8.4.4. | Send the EAC/AA (in accordance with Appendix 4.9). | NHHDC. | Supplier, NHHDA. | Appendix 4.9 - EAC/AA Calculation. D0019 Metering System EAC/AA Data. If Gross Volume Correction is required, refer to section 3.4.4. | Electronic or other method, as agreed. |
|
| Process EAC/AA data in accordance with section 3.5. | NHHDA. |
|
|
|
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
For NHH Meters other than smart Meters | ||||||
3.3.10.1 | On change of Profile Class. | Send notification of intended change of Profile Class, including the initial value EAC, and if required, request that the NHHDC collects a Meter register reading. Await confirmation of the effective date of the Profile Class change from the NHHDC. | Supplier. | NHHDC. SMRA | D0005 Instruction on Action. D0052 Affirmation of Metering System Settlement Details. D0205 Update Registration Details | Electronic or other method, as agreed. |
3.3.10.2 | Within 10 WD of notification from Supplier. | Either: a) Obtain a Meter register reading80, or receive Meter register reading from SVA MOA, if there is a change of SSC. | NHHDC, SVA MOA. | NHHDC. | D0010 Meter Readings. | Internal Process. Electronic or other method, as agreed. |
|
| b) Send the Meter register reading to the Supplier together with the Meter register reading date. This date will become the effective date of the Profile Class change. If unable to obtain Meter register reading, the NHHDC will inform the Supplier and await further instructions. | NHHDC | Supplier81. |
| D0004 Notification of Failure to Obtain Reading. |
|
| Supplier will inform NHHDC of next course of action. | Supplier. | NHHDC. | D0005 Instruction on Action. |
|
|
| or If no Meter register reading required, confirm the effective date of the Profile Class change. | NHHDC. | Supplier96. | D0010 Meter Readings. |
|
3.3.10.3 |
| Send initial (class) average EAC. See Appendix 4.12 – Usage and Validation of Affirmation of Metering System Settlement Details (D0052) Flow | Supplier | NHHDC. SMRA | D0052 Affirmation of Metering System Settlement Details. D0205 Update Registration Details | Electronic or other method, as agreed. |
For smart Meters | ||||||
3.3.10.4 | On Change of Profile Class | Send notification of change of Profile Class, including the initial EAC value, and if required, any Meter reading(s) taken on the effective date of the Profile Class change. | Supplier | NHHDC | D0052 Affirmation of Metering System Settlement Details D0010 Meter Readings | Electronic or other method, as agreed. |
|
| Notify change of Profile Class | Supplier | SMRA | D0205 Update Registration Details |
|
For all Meters | ||||||
3.3.10.5 |
| Validate D0052. | NHHDC |
| See Appendix 4.12 – Usage and Validation of Affirmation of Metering System Settlement Details (D0052) Flow | Internal |
3.3.10.6 | If D0052 invalid | Send notification of invalid Metering System Settlement details to Supplier | NHHDC | Supplier | D0310 Notification of Failure to Load or Receive Metering System Settlement Details11 | Electronic or other method, as agreed. |
3.3.10.7 | On receipt of D0310 | Supplier should resolve the problem and re-send or revise D0052 as required | Supplier | NHHDC SMRA | D0052 Affirmation of Metering System Settlement Details. D0205 Update Registration Details As required | Electronic or other method, as agreed. |
3.3.10.8 | If Meter register reading not obtained for Profile Class change. | Send the initial value EAC which is effective from the Profile Class change. Process EAC/AA data in accordance with section 3.5. | NHHDC.
NHHDA. | NHHDA, Supplier. | D0019 Metering System EAC/AA Data. | Electronic or other method, as agreed. |
3.3.10.9 | Once Meter register reading obtained. | Calculate an AA based on the MAP and substitute a Class Average EAC with an Effective From Settlement Date set to the day after the Effective To Date of the AA Send the AA and the initial value EAC. Process EAC/AA data in accordance with section 3.5. | NHHDC. NHHDC. NHHDA. | NHHDA, Supplier. | D0019 Metering System EAC/AA Data. | Internal Process. Electronic or other method, as agreed. |
3.3.10.10 | On change of GSP Group. | Send notification of a change to the GSP Group. Validate D0052 and notify Supplier of any exceptions as per 3.3.10.5 to 3.3.10.7 above. Process in accordance with 3.3.5 - Disconnection and registration deactivation of a SVA Metering System and 3.2.1 - Supplier requests New Connection. | Supplier.
NHHDC
NHHDC. | NHHDC. SMRA Supplier | D0052 Affirmation of Metering System Settlement Details. D0205 Update Registration Details D0310 Notification of Failure to Load or Receive Metering System Settlement Details11 See Appendix 4.12 – Usage and Validation of Affirmation of Metering System Settlement Details (D0052) Flow | Electronic or other method, as agreed. Internal Process. |
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.3.11.1 | In accordance with SVAA Calendar. | Send Daily Profile Coefficients (via section 3.1.2 - Process Daily Profile Coefficients received from SVAA). | SVAA. | NHHDC82. | D0039 Daily Profile Coefficient File. | Electronic Interface. |
3.3.11.2 | If profile data not received. | Inform SVAA and await receipt of profile data. | NHHDC. | SVAA. | P0040 Request Daily Profile Coefficient | Manual Process. |
3.3.11.3 | Following receipt of profile data. | Calculate the AA and or EAC for the MAP, based on the valid Meter data83. Where the new EAC is negative, calculate a replacement EAC84. | NHHDC.85 |
| Check that the date and version stamps on sets of Daily Profile Coefficients received are consistent with those on data sets already received. Appendix 4.9 - EAC/AA Calculation. Appendix 4.5.2 e) – Replacement EAC/AA Calculation. | Internal Process. |
3.3.11.4 | If AA and or EAC calculation fails. | Correct and re-run AA and or EAC calculation. | NHHDC. |
|
| Internal Process. |
3.3.11.5 | If AA and or EAC calculation successful. By the next Volume Allocation Run, if the D0023 data flow was received from the NHHDA at least 14 WD before that Run, | Send AA and or EAC86 If problem with file not caused by NHHDA notify NHHDC Generate a revised file and send or resend an exact copy of file. | NHHDC87. NHHDA. NHHDC87 | NHHDA, Supplier88. NHHDC. NHHDA, Supplier. | D0019 Metering System EAC/AA Data. P0035 Invalid Data (for physical integrity problems) or D0023 Failed Instructions (for instruction level problems). D0019 Metering System EAC/AA Data. | Electronic Interface. |
| or by the Volume Allocation Run after next if the D0023 data flow from the NHHDA was received less than 14 WD before the next Reconciliation Run. |
|
|
|
|
|
3.3.11.6 | After 3.3.11.5 and by 20 WD after AA/EAC calculation. | Determine whether the AAs, which are outside the tolerances and have been included in the exception log, are invalid. Proceed in accordance with section 3.3.8.3 Withdrawal of Meter Reading following Review if any AA is invalid. | NHHDC. |
| Determine whether AA value is genuine. Appendix 4.9 - EAC/AA Calculation. | Internal Process. |
3.3.11.7 | By the 20th day of the month89. | Send notification of those AAs which were included in the excessively large AAs exception log in 3.3.11.6, and the status of each exception following investigation90. | NHHDC | Supplier91 | P0191 Excessively Large AA. | Manual Process |
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.3.12.1 | On notification | Inform Supplier of Incorrect Register Mapping. | NHHDC92 | Supplier | P0216 Notification of Incorrect Register Mapping | Electronic or other method as required |
3.3.12.2 | Within 5 WD of notification or discovery of incorrect register mapping | Instruct NHHDC to correct incorrect register mapping. | Supplier | NHHDC | P0216 Notification of Incorrect Register Mapping | Electronic or other method as required |
3.3.12.3 | Following 3.3.12.2 | Obtain Meter reading and correct register mapping. | NHHDC |
| Appendix 4.10 - Correction of Incorrect Meter Register Mapping | Internal Process |
3.3.12.4 | Within 5 WD of 3.3.12.3 | Correct Meter Register Mapping. | NHHDC |
| Appendix 4.10 - Correction of Incorrect Meter Register Mapping Proceed to section 3.4.1 – NHHDC collects and sends consumption / generation data to validate the meter register readings(s). | Internal Process |
3.3.12.5 | Within 5 WD of 3.3.12.3 | Notify the Supplier that suitable Meter reading is unavailable. | NHHDC | Supplier93 | P0216 Notification of Incorrect Register Mapping | Electronic or other method as required |
Ref | When | Action | From | To | Information Required | Method |
3.3.13.1 | Following receipt of second D000494. | Identification of site as Long Term Vacant in accordance with appendix 4.15.1 Establish start date for the Long Term Vacant period in accordance with appendix 4.15.2. | Supplier |
| Appendix 4.15 - Identification of a site as Long Term Vacant. | Internal Process |
3.3.13.2 | Following 3.3.13.1 | Send notification of zero EAC for the site, where the Effective From Date shall be the start date for the period of Long Term Vacant treatment. Send reading obtained through entry via a warrant if appropriate95 with a read date of the Effective From Date of the zero EAC. | Supplier | NHHDC | D0052 Affirmation of Metering System Settlement Details. D0010 Meter Readings | Electronic or other method, as agreed |
3.3.13.3 | Within 10 WD of receipt of D0052 | Obtain Meter reading for the Effective From Date of zero EAC. If Meter Register Reading is not available, deem a Meter reading in accordance with Appendix 4.5.2 (q) | NHHDC |
| Appendix 4.5 – Deemed Meter Advance. | Internal Process |
3.3.13.4 | If Meter reading is deemed | Send notification of deemed Meter reading for Effective From Date of zero EAC. | NHHDC | Supplier, LDSO | D0010 Meter Readings. | Electronic or other method, as agreed |
3.3.13.5 | Following 3.3.13.3 | Calculate AA up to the Effective From date of zero EAC. | NHHDC |
| Appendix 4.9 - EAC/AA Calculation. | Internal Process |
3.3.13.6 | Following 3.3.13.5 | Send AA and the zero EAC. | NHHDC | NHHDA Supplier | D0019 Metering System EAC/AA Data. | Electronic or other method, as agreed |
3.3.13.7 | On receipt of D0019 | Process Data in accordance with BSCP504 Section 3.5. | NHHDA |
| D0019 Metering System EAC/AA Data. | Internal Process |
3.3.13.8 | On Request by LDSO96 | Send Details of Long Term Vacant Sites. | Supplier | LDSO | P0221 ‘Notification of Long Term Vacant Site’. | As agreed between Supplier and LDSO |
3.3.13.9 | No later than 215 calendar days from identification or last confirmation of site as LTV | Confirm that site remains Long Term Vacant in accordance with Appendix 4.15.3. | Supplier |
| Appendix 4.15.3 - Confirmation that the Site remains Long Term Vacant. | Internal Process |
Ref | When | Action | From | To | Information Required | Method |
3.3.14.1 | As appropriate | Supplier identifies that site no longer qualifies for Long Term Vacant treatment in accordance with appendix 4.15.4. Establish end date for the Long Term Vacant period in accordance with appendix 4.15.5. | Supplier |
| Appendix 4.15 - Identification of a site as Long Term Vacant. | Internal Process |
3.3.14.2 | If Supplier has a Meter Reading for end of LTV Period97 | Send Meter Reading if not previously provided by the NHHDC. | Supplier | NHHDC | D0010 Meter Readings | Electronic or other method, as agreed |
3.3.14.3 | If Supplier has no Meter reading or as required, alongside 3.3.14.2 | If Supplier has no Meter reading to send or Supplier wishes to specify a different EAC to the one expected to be calculated by NHHDC; send non-zero EAC98. | Supplier | NHHDC | D0052 Affirmation of Metering System Settlement Details | Electronic or other method, as agreed |
3.3.14.4 | Within 10 WD of receipt of D0052 | If the Supplier did not provide Meter Register reading, obtain Meter Register reading for date of change of EAC value or deem Meter reading in accordance with appendix 4.5.2 (q) | NHHDC |
| Appendix 4.5 – Deemed Meter Advance | Internal Process |
3.3.14.5 | If Meter reading deemed | Notification of Deemed Meter Reading. | NHHDC | Supplier, LDSO | D0010 Meter Readings | Electronic or other method, as agreed |
3.3.14.6 | Following 3.3.14.4 | Calculate AA up to the Effective From Date of the new EAC or date of Meter reading. If no EAC provided by Supplier, calculate EAC. | NHHDC |
| Appendix 4.9 - EAC/AA Calculation. | Internal Process |
3.3.14.7 | Following 3.3.14.6 | Send EAC/AA Data. | NHHDC | NHHDA Supplier | D0019 Metering System EAC/AA Data | Electronic or other method, as agreed |
3.3.14.8 | On receipt of file. | Process EAC/AA data in accordance with 3.5. | NHHDA. |
| D0019 Metering System EAC/AA Data. | Internal Process. |
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD | |||||
3.3.15.1 | Within the period of 1WD commencing on the Business Day after the BMRA receives the data from the NETSO specified in Section Q6.9.5 | Notice of the DCE sent to all Category A Authorised Persons, to establish the appropriate operational contact. The Category A Authorised Persons will be used as the contact unless another contact is provided | BSCCo | Category A Authorised Persons from BSC Parties and Party Agents | Notice of the DCE | Email or other method, as agreed. | |||||
3.3.15.2 | Within the period of 1WD commencing on the Business Day after the BMRA receives the data from the NETSO specified in Section Q6.9.5 | BSCCo will assess the costs and value of the DCE in accordance with the Demand Disconnection Event Threshold Rules and notify BSC Parties, Party Agents and BSC Panel Members of the outcome of its assessment | BSCCo | BSC Parties, Party Agents and BSC Panel | Notice of the outcome of BSCCo assessment | Email, Circular, BSC Website | |||||
3.3.15.3 | Within 5WD of 3.3.15.2 | Send notification of Demand Control Event and all affected MSIDs99 | LDSO | BSCCo | P0238 MSIDs affected by Demand Control Event100 - the P0238 contains details of all MSIDs disconnected by the LDSO, i.e. for a single Demand Control Event, a single P0238 is sent by the LDSO, ultimately, to all DCs and DAs. | Email to bscservicedesk@cgi.com | |||||
3.3.15.4 | Within 1WD of 3.3.15.3 | Acting on behalf of LDSOs, BSCCo will forward notifications received from LDSOs to NHHDCs, NHHDAs, SVAA | BSCCo | NHHDC, NHHDA, SVAA | P0238 MSIDs affected by Demand Control Event |
| |||||
3.3.15.5 | Within 1WD of 3.3.15.4 | Send daily profile data for all Settlement Dates with one or more Demand Control Impacted Settlement Periods | SVAA | NHHDC | D0018 Daily Profile Data Report | Electronic or other method, as agreed | |||||
3.3.15.6 | If profile data not received. | Inform SVAA and await receipt of profile data. | NHHDC | SVAA. | Raise with SVAA | Email to bscservicedesk@cgi.com | |||||
3.3.15.7 | Following receipt of P0238 (and D0018) | Calculate Estimated Annual Consumption and Annualised Advances for MSIDs affected by Demand Control Event | NHHDC |
| Appendix 4.9 – EAC/AA Calculation | Internal | |||||
|
| Send EAC/AA | NHHDC | NHHDA | D0019 Metering System EAC/AA Data | Electronic or other method, as agreed | |||||
3.3.15.8 | Within 1WD of receiving P0241 from the National Electricity Transmission System Operator NETSO | Send notification of any MSIDs subject to demand side Non-BM STOR instruction along with estimated volumes of reduction | SVAA | NHHDC, NHHDA | D0375 Disconnected MSIDs and Estimated Half Hourly Demand Disconnection Volumes | Electronic or other method, as agreed | |||||
3.3.15.9 | Following receipt of D0375 in 3.3.15.8, if required | Recalculate Estimated Annual Consumption and Annualised Advances for MSIDs affected by Non-BM STOR instruction | NHHDC |
| Appendix 4.9 – EAC/AA Calculation | Internal | |||||
|
| Send EAC/AA | NHHDC | NHHDA | D0019 Metering System EAC/AA Data | Electronic or other method, as agreed |
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.3.16.1 | As required. | Send notification of termination of appointment. | Supplier59 | NHHDC. | D0151 Termination of Appointment or Contract by Supplier. | Electronic or other method, as agreed. |
3.3.16.2 | Within 5 working days of Change of Measurement Class. | Send final Meter register reading(s). | Supplier. | NHHDC. | D0010 Meter Readings. | Electronic or other method, as agreed. |
3.3.16.3 | Within 3 working days of 3.3.16.2. | If Meter register reading(s) obtained, validate Meter register reading(s). | NHHDC. |
| Appendix 4.2 – Validate Meter Data, Appendix 4.6 – Manual Adjustment of Meter Reading(s). | Internal Process. |
3.3.16.4 | Within 3 working days of 3.3.16.2. | If valid Meter register reading(s), produce and send Valid Data Report. | NHHDC. | Supplier, LDSO. | D0010 Meter Readings. Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Electronic or other method, as agreed. |
3.3.16.5 | Within 3 working days of 3.3.16.2. | If invalid Meter register reading(s), produce and send Invalid Data Report. | NHHDC. | Supplier, LDSO. | D0010 Meter Readings. | Electronic or other method, as agreed. |
3.3.16.6 | If Meter register reading invalid or not received within 8 working days of Change of Measurement Class date. | Calculate deemed reading(s) and associated EAC/AA(s). | NHHDC. |
| Appendix 4.5 – Deemed Meter Advance. Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Internal Process. |
3.3.16.7 | By SSD+8. | Send Deemed Meter Reading(s). | NHHDC. | Supplier, LDSO. | D0010 Meter Readings. Refer to section 3.3.11 Calculate AA/EAC and send to NHHDA and Supplier. | Electronic or other method, as agreed. |
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.3.17.1 | Prior to SSD. | Send notification of termination of appointment. | Old Supplier59 | NHHDC. | D0151 Termination of Appointment or Contract by Supplier. | Electronic or other method, as agreed. |
3.3.17.2 | From SSD43 | The New Supplier retrieves the midnight SSD46 register reading(s). The New Supplier will also take instantaneous readings, including the total cumulative register reading and all time of use register readings47. The readings should be synchronised with the successful reconfiguration of the Meter, where applicable. If the new Supplier is unable to configure the Meter until after SSD+5 WD, the new Supplier will use the change of SSC process in 3.3.6 and will adopt the old Supplier’s SSC for the intervening period. Where not available from the Meter, the Supplier will attempt to obtain a Total Cumulative Reading from the old Supplier or the customer. | New Supplier. |
|
| Internal Process. |
3.3.17.3 | If the new Supplier has been able to obtain a reading(s) and within 3 WD of 3.3.17.2. | Send reading(s) to Old Supplier. The new Supplier will send the old Supplier all the instantaneous readings taken on configuration of the Meter, including the total cumulative register reading and all 48 time of use register readings. | New Supplier. | Old Supplier. | D0010 Meter Readings. | Electronic or other method, as agreed. |
3.3.17.4 | Within 5 working days of SSD. | Send final Meter register reading(s). | Old Supplier. | NHHDC. | D0010 Meter Readings. | Electronic or other method, as agreed. |
3.3.17.5 | Within 8 working days of SSD. | If Meter register reading(s) obtained, validate Meter register reading(s). | NHHDC. |
| Appendix 4.2 – Validate Meter Data, Appendix 4.6 – Manual Adjustment of Meter Reading(s). | Internal Process. |
3.3.17.6 | Within 8 working days of SSD. | If valid Meter register reading(s), produce and send Valid Data Report. | NHHDC. | Old Supplier, LDSO. | D0086 Notification of Change of Supplier Readings. Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Electronic or other method, as agreed. |
3.3.17.7 | Within 8 working days of SSD. | If invalid Meter register reading(s), produce and send Invalid Data Report. | NHHDC. | Old Supplier, LDSO. | D0010 Meter Readings. | Electronic or other method, as agreed. |
3.3.17.8 | If Meter register reading invalid or not received within 8 working days of Change of Measurement Class date. | Calculate deemed reading(s) and associated EAC/AA(s). | NHHDC. |
| Appendix 4.5 – Deemed Meter Advance. Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Internal Process. |
3.3.17.9 | By SSD+8. | Send Deemed Meter Reading(s). | NHHDC. | Old Supplier, LDSO. | D0086 Notification of Change of Supplier Readings. Refer to section 3.3.11 Calculate AA/EAC and send to NHHDA and Supplier. | Electronic or other method, as agreed. |
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.3.18.1 | As required. | Send appointment. | Supplier. | NHHDC. | D0155 Notification of New Meter Operator or Data Collector Appointment and Terms. | Electronic or other method, as agreed. |
3.3.18.2 | If appointment rejected and within 10 WD of 3.3.18.1. | Send notification of rejection of appointment including the reason why the request has been rejected. | NHHDC. | Supplier. | D0261 Rejection of Agent Appointment. (Go to 3.3.18.1 if required). | Electronic or other method, as agreed. |
3.3.18.3 | If appointment accepted and within 10 WD of 3.3.18.1. | Send notification of acceptance of appointment. | NHHDC. | Supplier. | D0011 Agreement of Contractual Terms. | Electronic or other method, as agreed. |
3.3.18.4 | Within 5 WD of 3.3.18.3. | Send associated Agent details. | Supplier. | NHHDC. | D0148 Notification of Change to Other Parties and, optionally D0302 Notification of Customer Details. | Electronic or other method, as agreed. |
3.3.18.5 |
| Send MTD. Where the Supplier has been unable to configure the Meter (for example, due to a communications failure), the SSC and TPR contained in the MTD from the SVA NHHMOA will be those held while the Metering System was being traded HH. | SVA NHHMOA. | Supplier, NHHDC, LDSO. | D0149 Notification of Mapping Details. D0150 Non-Half Hourly Meter Technical Details. | Electronic or other method, as agreed. |
3.3.18.6 | Within 5 WD of receipt of D0150 from the SVA MOA. | Send notification of SVA Metering System details, including initial (class average) EAC to the NHHDC. | Supplier. | NHHDC, SMRA. | D0052 Affirmation of Metering System Settlement Details. D0205 Update Registration Details. See Appendix 4.12 – Usage and Validation of Affirmation of Metering System Settlement Details (D0052) Flow. | Electronic or other method, as agreed. |
3.3.18.7 | On receipt of D0052 and D0150. | Validate D0052. Check for discrepancies between the Metering System Settlement Details provided by the Supplier and the Meter Technical Details provided by the SVA MOA. | NHHDC. |
| See Appendix 4.12 – Usage and Validation of Affirmation of Metering System Settlement Details (D0052) Flow. | Internal. |
3.3.18.8 | If D0052 invalid. | Send notification of invalid Metering System Settlement details to Supplier. | NHHDC. | Supplier. | D0310 Notification of Failure to Load or Receive Metering System Settlement Details11. | Electronic or other method, as agreed. |
3.3.18.9 | On receipt of D0310. | Supplier should resolve the problem by re-sending or revising the D0052 as required or by instructing the SVA MOA to re-send the D0150. | Supplier. | NHHDC, SMRA | D0052 Affirmation of Metering System Settlement Details. D0205 Update Registration Details. As required. | Electronic or other method, as agreed. |
3.3.18.10 | On receipt of valid D0052. | Send the initial (class average) EAC for each Settlement register of the SVA MS to the NHHDA. Process EAC/AA data in accordance with section 3.5. | NHHDC. | NHHDA. | D0019 Metering System EAC/AA Data. | Electronic or other method, as agreed. |
3.3.18.11 | As soon as possible following the CoMC effective date. | The Supplier retrieves the CoMC effective date midnight44 register reading(s). The Supplier will also take instantaneous readings, including the total cumulative register reading and all time of use register readings47. The readings should be synchronised with the successful reconfiguration of the Meter, where applicable. | Supplier. |
|
| Internal process. |
3.3.18.12 | Following 3.3.18.11. | Send initial Meter register reading(s). | Supplier. | NHHDC. | D0010 Meter Readings. | Electronic or other method, as agreed. |
3.3.18.13 | On receipt of D0010. | Process and validate Meter register reading. | NHHDC. |
| Appendix 4.2 – Validate Meter Data, Appendix 4.6 – Manual Adjustment of Meter Reading(s). | Internal Process. |
3.3.18.14 | If invalid Meter register reading. | Produce and send Invalid Data Report. | NHHDC. | LDSO, Supplier. | D0010 Meter Readings. | Electronic or other method, as agreed. |
3.3.18.15 | If valid Meter register reading | Produce and send Valid Data Report. | NHHDC. | LDSO, Supplier. | D0010 Meter Readings. Refer to section 3.3.11 Calculate AA/EAC and send to NHHDA and Supplier. | Electronic or other method, as agreed. |
3.3.18.16 | If a D0002 received or no D0010 or D0002 received by 10 WD after the Change of Measurement Class date. | Deem initial Meter reading in accordance with Appendix 4.5 and calculate associated EAC / AA(s). | NHHDC. |
| Appendix 4.5 – Deemed Meter Advance. Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Internal Process. |
3.3.18.17 | Following 3.3.18.16. | Send Deemed Meter Reading. | NHHDC. | Supplier, LDSO. | D0010 Meter Readings. | Electronic or other method as agreed. |
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.3.19.1 | By SSD – 1 WD | Send appointment. | New Supplier. | NHHDC. | D0155 Notification of New Meter Operator or Data Collector Appointment and Terms. | Electronic or other method, as agreed. |
3.3.19.2 | If appointment rejected and within 2 WD of 3.3.19.1. | Send notification of rejection of appointment including the reason why the request has been rejected. | NHHDC. | New Supplier. | D0261 Rejection of Agent Appointment. (Go to 3.3.19.1 if required). | Electronic or other method, as agreed. |
3.3.19.3 | If appointment accepted and within 2 WD of 3.3.19.1. | Send notification of acceptance of appointment. | NHHDC. | New Supplier. | D0011 Agreement of Contractual Terms. | Electronic or other method, as agreed. |
3.3.19.4 | Within 1 WD of 3.3.19.3. | Send associated Agent details. | New Supplier. | NHHDC. | D0148 Notification of Change to Other Parties and, optionally D0302 Notification of Customer Details. | Electronic or other method, as agreed. |
3.3.19.5 |
| Send MTD. | SVA NHHMOA. | New Supplier, NHHDC, LDSO. | D0149 Notification of Mapping Details. D0150 Non-Half Hourly Meter Technical Details. | Electronic or other method, as agreed. |
3.3.19.6 | Within 1 WD of 3.3.19.4. | Send notification of SVA Metering System details, including initial (class average) EAC to the NHHDC. | New Supplier. | NHHDC, SMRA. | D0052 Affirmation of Metering System Settlement Details. D0205 Update Registration Details. See Appendix 4.12 – Usage and Validation of Affirmation of Metering System Settlement Details (D0052) Flow. | Electronic or other method, as agreed. |
3.3.19.7 | On receipt of D0052 and D0150. | Validate D0052. Check for discrepancies between the Metering System Settlement Details provided by the Supplier and the Meter Technical Details provided by the SVA MOA. | NHHDC. |
| See Appendix 4.12 – Usage and Validation of Affirmation of Metering System Settlement Details (D0052) Flow. | Internal. |
3.3.19.8 | If D0052 invalid. | Send notification of invalid Metering System Settlement details to Supplier. | NHHDC. | New Supplier. | D0310 Notification of Failure to Load or Receive Metering System Settlement Details11. | Electronic or other method, as agreed. |
3.3.19.9 | On receipt of D0310. | Supplier should resolve the problem by re-sending or revising the D0052 as required or by instructing the SVA MOA to re-send the D0150. | New Supplier. | NHHDC, SMRA. | D0052 Affirmation of Metering System Settlement Details. D0205 Update Registration Details. As required. | Electronic or other method, as agreed. |
3.3.19.10 | On receipt of valid D0052. | Send the initial (class average) EAC for each Settlement register of the SVA MS to the NHHDA. Process EAC/AA data in accordance with section 3.5. | NHHDC. | NHHDA. | D0019 Metering System EAC/AA Data. | Electronic or other method, as agreed. |
3.3.19.11 | As soon as possible following the CoMC effective date. | The New Supplier retrieves the midnight SSD44 register reading(s). The New Supplier will also take instantaneous readings, including the total cumulative register reading and all time of use register readings47. The readings should be synchronised with the successful reconfiguration of the Meter, where applicable. If the new Supplier is unable to configure the Meter until after SSD+5 WD, the new Supplier will use the change of SSC process in 3.3.6 and will adopt the old Supplier’s SSC for the intervening period. Where not available from the Meter, the Supplier will attempt to obtain a Total Cumulative Reading from the old Supplier or the customer. | New Supplier. |
|
| Internal process. |
3.3.19.12 | Following 3.3.19.11. | Send initial Meter register reading(s). The new Supplier will send the old Supplier all the instantaneous readings taken on configuration of the Meter, including the total cumulative register reading and all 48 time of use register readings, The new Supplier will send the NHHDC the register readings associated with the Metering System’s (new) Standard Settlement Configuration / Time Pattern Regime(s). | New Supplier. | NHHDC, Old Supplier | D0010 Meter Readings. | Electronic or other method, as agreed. |
3.3.19.13 | On receipt of D0010. | Process and validate Meter register reading. | NHHDC. |
| Appendix 4.2 – Validate Meter Data, Appendix 4.6 – Manual Adjustment of Meter Reading(s). | Internal Process |
3.3.19.14 | If invalid Meter register reading. | Produce and send Invalid Data Report. | NHHDC. | LDSO, New Supplier. | D0010 Meter Readings. | Electronic or other method, as agreed. |
3.3.19.15 | If valid Meter register reading. | Produce and send Valid Data Report. | NHHDC. | LDSO, New Supplier. | D0086 Notification of Change of Supplier Readings. Refer to section 3.3.11 Calculate AA/EAC and send to NHHDA and Supplier. | Electronic or other method, as agreed. |
3.3.19.16 | If a D0002 received or no D0010 or D0002 received by 10 WD SSD. | Deem initial Meter reading in accordance with Appendix 4.5 and calculate associated EAC / AA(s). | NHHDC. |
| Appendix 4.5 – Deemed Meter Advance. Refer to section 3.3.11 Calculate AA/EAC Values and send to NHHDA and Supplier. | Internal Process. |
3.3.19.17 | Following 3.3.19.16. | Send Deemed Meter Reading. | NHHDC. | New Supplier, LDSO. | D0010 Meter Readings. | Electronic or other method as agreed. |
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.4.1.1 |
| Metered Supply: |
|
|
|
|
|
| Collect Meter register reading(s)101 for designated SVA MS(s) either directly or via Supplier. | NHHDC. |
| Complete Site Visit of SVA Metering System – Site Visit Report - Appendix 4.1. | Internal Process. |
|
| Send smart Meter register readings, customer Meter register reading or prepayment Meter register reading to NHHDC. | Supplier. | NHHDC. | D0010 Meter Readings. Prepayment Meters – Appendix 4.11 Remotely Read Meters – Appendix 4.20 | Electronic or other method, as agreed. |
|
| Send customer reading(s) directly to NHHDC. | Customer. | NHHDC. | Customer Reading Details |
|
|
| Inform of possible safety problem(s). | NHHDC. | SFIC. | D0135 Report Possible Safety Problem. | Electronic or other method |
|
| Inform of possible irregularities. | NHHDC. | Supplier | D0136 Report to Supplier of Possible Irregularity. | Electronic or other method |
|
| Unmetered Supply: |
|
|
|
|
|
| Send UMS EAC | UMSO/ Supplier | SMRA | D0052 Affirmation of Metering System Settlement Details102 D0205 Update Registration Details | Electronic or other method, as agreed. |
3.4.1.2 | If Meter register reading(s) unobtainable. | Add SVA MS(s) to next collection rota. | NHHDC. |
|
| Internal Process. |
3.4.1.3 | On receipt of D0052 from UMSO. | Validate D0052. | NHHDC |
| See Appendix 4.12 – Usage and Validation of Affirmation of Metering System Settlement Details (D0052) Flow | Internal Process. |
3.4.1.4 | If D0052 is invalid. | Send notification of invalid Metering System Settlement details. | NHHDC | UMSO, Supplier | D0310 Notification of Failure to Load or Receive Metering System Settlement Details11 | Electronic or other method, as agreed. |
3.4.1.5 | If Meter register reading(s) obtained. | Process103 and validate Meter register reading(s). If SVA MS recorded as de-energised but consumption identified either remotely or by visiting the site record and process this data. | NHHDC. |
| Appendix 4.2 - Validate Meter Data, Appendix 4.6 - Manual Adjustment of Meter Reading(s). | Internal Process |
3.4.1.6 | If invalid Meter register reading(s). | Produce and send Invalid Data Report. | NHHDC. | Supplier, LDSO | D0010 Meter Readings. | Electronic or other method, as agreed. |
3.4.1.7 | If valid Meter register reading(s). | Produce and send Valid Data Report104. | NHHDC. | Supplier, LDSO | D0010 Meter Readings. Refer to section 3.3.11 - Calculate AA/EAC Values and send to NHHDA and Supplier. | Electronic or other method, as agreed. |
3.4.1.8 | By 7th calendar day of each month. | Produce and send report relating to previous calendar month detailing whether 100kW demand was identified in Metering Systems for which the NHHDC is the appointed NHHDC within the period of the report. | NHHDC. | Supplier. | P0028 100kW Demand Report - if no 100kW demand is identified, a ‘nil’ P0028 report. | Electronic or other method, as agreed. |
REF | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.4.2.1 | As deemed necessary. | Send notification of inconsistencies e.g. any gaps, overlaps, missing or invalid AAs etc. | Supplier SVA MOA NHHDA. | NHHDC. | As appropriate: Details of inconsistencies to be investigated, including any relevant supporting information (e.g. copies of data flows highlighting the inconsistencies). | Electronic or other method, as agreed. |
3.4.2.2 |
| Investigate inconsistencies 105,106 take corrective action and inform respective parties of action taken. | NHHDC. |
| Complete Site Visit of SVA Metering System – Site Visit Report - Appendix 4.1. | Electronic or other method, as agreed. |
|
| Re-send AAs (and EACs if previously sent) to the NHHDA and Supplier. Process EAC/AA data in accordance with section 3.5. | NHHDA. | Supplier, NHHDA. | D0019 Metering System EAC/AA Data. |
|
REF. | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.4.3.1 | In the circumstances defined in Appendix 4.14 | Request that Gross Volume Correction is carried out | Supplier | NHHDC | Details of Meter register readings to which Gross Volume Correction should be applied. | Fax / Email / Post |
3.4.3.2 | As soon as possible after 3.4.3.1 | Where NHHDC believes that request for Gross Volume Correction does not meet the criteria in Appendix 4.14, refer request back to Supplier along with supporting rationale Return to 3.4.3.1 | NHHDC | Supplier | Appendix 4.14 – Gross Volume Correction Details of application of Gross Volume Correction in 4.14.3 – ‘Use of Gross Volume Correction’ | Fax / Email / Post |
3.4.3.3 | As soon as possible after 3.4.3.1 or as otherwise agreed with the Supplier | Where appropriate, carry out Gross Volume Correction107 | NHHDC |
| Appendix 4.14 – Gross Volume Correction | Internal Process |
3.4.3.4 | Following completion of Gross Volume Correction | Send notification of Deemed Meter Readings used for Gross Volume Correction | NHHDC | Supplier | D0010 Meter readings | Electronic or other method as agreed |
|
| Send notification of revised EAC / AAs The revised AA/EAC will be calculated in accordance with section 3.3.11. The EAC value sent to the NHHDA and Supplier will normally be that calculated in accordance with step 3.3.11.3, but may be substituted in accordance with step 4.14.4.7 | NHHDC | Supplier, NHHDA | D0019 Metering System EAC/AA Data Process EAC / AA in accordance with section 3.5 |
|
REF. | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.5.1 | On receipt of file. | Perform validation checks. | NHHDA. |
| D0019 Metering System EAC/AA Data. | Internal Process. |
3.5.2 | If validation successful. | Update database with instruction data. | NHHDA. |
| D0019 Metering System EAC/AA Data. | Internal Process. |
3.5.3. | If validation unsuccessful. | Notify NHHDC of problem. | NHHDA. | NHHDC. | P0035 Invalid Data (for transmission problems). D0023 Failed Instructions (for instruction level validation problems). | Electronic or other method, as agreed. |
3.5.4 | Upon receipt of failure notification. | If transmission problem, resend exact copy of instruction file with the same file sequence number. | NHHDC. | NHHDA, Supplier. | D0019 Metering System EAC/AA Data. Resend an exact copy of an instruction file with the same file sequence number D0019 Metering System EAC/AA Data. As appropriate. | Electronic or other method, as agreed. |
|
| Upon request by the NHHDA | NHHDC | NHHDA |
|
|
|
| If file validation problem, generate and send revised file. |
| NHHDA, Supplier. |
|
|
|
| If problem believed to be caused by NHHDA, notify NHHDA. |
| NHHDA. |
|
|
3.5.5 | When notified of any other file instruction file error by the NHHDA | Resolve the problem and generate a revised instruction file containing all instructions required to rectify the situation. | NHHDC | NHHDA | The revised file shall contain all instructions from the erroneous file and any instructions contained in subsequent files sent to the NHHDA | Electronically or other method, as agreed. |
3.5.6 | Following 3.5.5 and 3.5.6 | Inform of the file sequence number of the revised file and send the revised instruction file | NHHDC | NHHDA |
| Electronically or other method, as agreed. |
3.5.7 | Notification from NHHDA of error within an instruction | Rectify the erroneous instruction and re-send the instruction in the next instruction file with a new instruction number contiguous in that file | NHHDC | NHHDA |
| Electronically or other method, as agreed. |
3.5.8 | Following the correction of an error. | When sending a revised file or re-sending a copy of an instruction file to its NHHDA, provide the same files to the Supplier. | NHHDC | Supplier |
| Electronically or other method, as agreed. |
REF. | WHEN | ACTION | FROM | TO | INFORMATION REQUIRED | METHOD |
3.6.1 | When informed by the Revenue Protection Service that there is evidence of tampering with a SVA Metering System | Record an adjustment to the meter advance based on the unrecorded units estimated by the Revenue Protection Service. | NHHDC |
|
| Internal Process. |
3.6.2 | After 3.6.1 occurs | Calculate a new EAC and AA based on the adjusted meter advance and send the new EAC/AA | NHHDC | NHHDA Supplier | D0019 ‘Metering System EAC/AA Data’ | Electronically or other method, as agreed. |
In the case of validating a Meter reading, using subsequent Meter readings, the date of the reading to be validated against will be before the date of the reading used to validate;
In the case of validating a Meter reading, using Meter readings either side, the date of the reading to be validated against will be between the date of the readings used to validate; and
The reading(s) used in validation will not have passed BSC Validation as there would have been nothing to validate these readings against.
the class average Estimated Annualised Consumption (EAC) times the profile coefficient or some other equivalent method, and the first Meter reading available; or
the Annualised Advance (AA), determined from two readings either side of the reading to be validated, times the Profile Coefficient.
To deem a CoS reading, in accordance with section 4.5.2.a); and
In the same way as any other Meter reading for validation purposes, once the PoS reading has been entered into the Meter reading history.
Deemed Meter Advance | As defined in Annex X-2 of the Code |
Deemed Meter Advance Period | As defined in Annex S-2 of the Code |
Deemed Meter Reading | As defined in Section 1.6.2 |
Last Valid EAC | An EAC which has been created from the last valid AA for a Particular Metering System. Where the Last Valid EAC cannot be calculated as there is no last valid AA, the Last Valid EAC will be defined as the initial (class average) EAC |
Change of Supplier;
Disputed change of Supplier Meter reading;
Concurrent change of Supplier and Change of Measurement Class;
Change of LDSO;
At the RF to ensure that crystallised data is not changed post the RF; and
To cleanse negative Estimates of Annual Consumption where requested by the Supplier.
Meter reading: the last valid Meter reading taken (or if not available, deemed).
Applicable EAC/AA for calculation of Deemed Meter Advance: the last valid EAC.
Deemed Meter Advance Period: starting on the date of the last valid Meter reading and ending on the day before the date of the change in value of the EAC.
Meter reading: the Meter reading taken or deemed when the zero EAC was entered into Settlement
Applicable EAC/AA for calculation of Deemed Meter Advance: the last Valid EAC (i.e. zero EAC)
Deemed Meter Advance Period: starting on the day when the zero EAC was entered into Settlement and ending on the day before the date of the change in value of the EAC from zero to non-zero.
Calculate a Deemed Meter Advance in accordance with 4.5.2e) and using the negative EAC value reported by the Supplier;
Use the resultant negative Deemed Meter Advance to calculate a negative AA and positive replacement EAC in accordance with 3.3.11; and
Submit the revised EAC (and optionally the negative AA) to the NHHDA in accordance with 3.3.11.
the number of SVA Metering Systems;
the number of SVA Metering Systems for which no Estimated Annual Consumption/Annualised Advance or Deemed meter advance has been calculated;
the number of SVA Metering Systems for which an Estimated Annual; and
Consumption/Annualised Advance or a Deemed meter advance has been calculated.
Scenario | Action |
Multiple P0238s | |
Demand Control Event ID – different LDSO MPID - different | EAC/AA system treats new P0238 as though a new Demand Control Event |
Demand Control Event ID – same LDSO MPID - same | EAC/AA system treats new P0238 as replacement of earlier P0238 |
Demand Control Event ID – different LDSO MPID - same | EAC/AA system treats new P0238 as though a new Demand Control Event |
Demand Control Event ID – same LDSO MPID – different | EAC/AA system treats new P0238 as incremental set of MSIDs to earlier P0238 MSIDs |
Multiple D0375s | |
In all cases the EAC/AA system first checks a new D0375’s Demand Control Event ID against existing P0238 Demand Control Event Id. Where no corresponding P0238 or where D0375 contains MSIDs that are not in P0238, EAC/AA system rejects new D0375. NHHDC should raise issue with SVAA via the BSC Service Desk. | |
Demand Control Event ID – different | EAC/AA system treats new D0375 as though a new Demand Control Event |
Demand Control Event ID - same | EAC/AA system treats new D0375 as replacement of earlier D0375 |
Ensure that a ‘Non-Half-Hourly Meter Technical Details’ (D0150) flow has been received from the Meter Operator, before sending a D0052115;
Check that the Standard Settlement Configuration (SSC) on the D0150 matches the SSC requested on the ‘Request for Installation or Change to a Metering System Functionality or the Removal of All Meters’ (D0142) flow. If there is a mismatch between the SSC on D0150 and the D0142, the Supplier should resolve with the SVA MOA, but pending resolution of the mismatch, should send a D0052 to match the D0150;
Ensure that where there has been a change to SSC Id, Profile Class (PC) Id or Measurement Class (MC) Id the effective date on the D0052 matches that on the D0150;
Send an ‘Update Registration Details’ (D0205) flow to SMRS at the same time as the D0052 is sent to the NHHDC, in order to avoid SMRS-NHHDC mismatches on the NHH Data Aggregation Exception Report (D0095).
Where applicable (i.e. when the SVA MOA has been requested to configure the Meter), ensure that a ‘Non-Half-Hourly Meter Technical Details’ (D0150) flow has been received from the Meter Operator, before sending a D0052;115
Where applicable, check that the Standard Settlement Configuration (SSC) on the D0150 matches the SSC requested on the ‘Request for Installation or Change to a Metering System Functionality or the Removal of All Meters’ (D0142) flow. If there is a mismatch between the SSC on D0150 and the D0052, the Supplier should correct the configuration remotely. Pending resolution of the mismatch by the Meter Operator, the Supplier should send a D0052 to match the D0150;
Ensure that where there has been a change to SSC Id, Profile Class (PC) Id or Measurement Class (MC) Id the effective date on the D0052 matches that on the D0150;
Send an ‘Update Registration Details’ (D0205) flow to SMRS at the same time as the D0052 is sent to the NHHDC, in order to avoid SMRS-NHHDC mismatches on the NHH Data Aggregation Exception Report (D0095).
Check that the SSC on the D0052 (where there has been a change of SSC or the NHH Metering System is new) matches the SSC value on the D0150 from the SVA MOA and notify the Supplier of any mismatch.
Notify the Supplier if the D0052 indicates that a D0150 is expected, but no D0150 has been received or if the D0150 indicates that a D0052 is expected, but no D0052 has been received.
Notify the Supplier if a D0052 has not been processed, either because its contents are identical to the data values already held by the NHHDC or because the NHHDC has been unable to derive the context in which the flow is being sent from the contents of the flow.
Where the NHHDC already holds a calculated EAC (i.e. associated with an AA) this should be used in preference to any EAC provided on the D0052, except where there has been a change of PC and/or SSC concurrent with the CoS/CoNHHDC, or where the site has been determined to be Long Term Vacant.
Where the NHHDC only holds an initial EAC, then the value provided by the Supplier on the D0052 should replace it.
A D0052 may not be considered invalid on the basis of an inconsistency in the Effective From Settlement Date of the SSC Id, PC Id, GSP Group Id or MC Id except where there has been a change to the associated data item. Where a D0052 is received and the SSC Id, PC Id, GSP Group Id or MC Id are identical to those already held by the NHHDC, but the Effective From Settlement Dates of one or more of these items are different to those already held by the NHHDC, the NHHDC will load the D0052, but may retain the original Effective From Settlement Dates in preference to those notified on the D0052. This is subject to the D0052 being otherwise valid. This ensures that where the Supplier has aligned Effective From Settlement Dates to the SSD, the NHHDC can do likewise or can retain its original dates.
Check that the Metering System ID on the flow is registered as an Unmetered Supply in the NHHDC system;
Check that the short code of the UMSO’s associated LDSO matches the first two digits of the Metering System ID;
Check that the Measurement Class ID on the flow is ‘B’ – Non-Half Hourly Unmetered;
Check that the Standard Settlement Configuration (SSC) on the flow is an Unmetered Supply SSC;
Check that the PC on the flow corresponds correctly to the SSC;
Check that the UMS SSC is appropriate to the relevant GSP Group; and
Notify the UMSO and the Supplier via the D0310, if the D0052 is invalid.
A D0052 may not be considered invalid on the basis of an inconsistency in the Effective From Settlement Date of the SSC Id, PC Id, GSP Group Id or MC Id except where there has been a change to the associated data item. Where a D0052 is received and the SSC Id, PC Id, GSP Group Id or MC Id are identical to those already held by the NHHDC, but the Effective From Settlement Dates of one or more of these items are different to those already held by the NHHDC, the NHHDC will load the D0052, but may retain the original Effective From Settlement Dates in preference to those notified on the D0052. This is subject to the D0052 being otherwise valid. This ensures that where the UMSO has aligned Effective From Settlement Dates to the SSD, the NHHDC can do likewise or can retain its original Effective From Settlement Dates.
A D0052 may not be considered invalid on the basis of the Effective From Settlement Date of the Initial EAC except where there is a change of SSC.
When receiving a D0052 with a backdated Effective From Settlement Date, all previously-supplied D0052 data effective after that date should be overwritten.
Compensatory Period | The period between the Error freezing reading and the Error Correcting Reading, in which an error is compensated using GVC. |
Correct Volume | The Meter Advance between the last valid reading before the Error Period and the Error Correcting Reading. |
Correct Volume in Error Period | An estimate of the Meter Advance that should have been settled for the period between the last valid reading before the Error Period and the Error freezing reading, calculated in accordance with 4.14.6. |
Crystallised Period | Periods of Settlement Dates for which RF has taken place and data cannot be amended without the support of an upheld Trading Dispute. |
Error Correcting Reading | The first actual reading in the Fluid Period which has been determined to be valid or a reading in the Fluid Period deemed in accordance with 4.14.4.3. |
Error freezing reading | This is a reading deemed in the current RF Window to prevent error that has crystallised being amended. It is calculated using the last valid, erroneous or compensatory Meter reading(s) obtained before and / or after RF and the associated erroneous EAC / AA that was in place at RF. Error freezing readings can only be deemed in the current RF Window. They should not be created at (or close to) the latest Post Final Settlement Run (PFSR), even in the case where the erroneous EAC or AA is subject to an authorised Trading Dispute. |
Error Period | The period between the last valid reading in the Crystallised Period and the Error freezing reading. |
Error Volume | An estimate of the volume of energy compensated for by the use of Gross Volume Correction. Calculated as the difference between the Volume in Error Period and the Correct Volume in Error Period. |
Fluid Period | Periods of Settlement Dates for which RF has not taken place |
Realistic reading | Where a Meter reading is required for a particular Settlement Day to carry out Gross Volume Correction and an actual Meter reading is not available, a realistic reading can be deemed for that Settlement Day using a valid Meter register reading (occurring prior to or after the realistic reading date) and a realistic EAC (i.e. a previous valid EAC or if one is not available an initial (class average) EAC). |
RF Window | This is the window of time between 5WD and 20WDs prior to the RF being carried out for a particular Settlement Day (i.e. a window in the period before that Settlement Day has passed through RF). A reading for RF should be deemed in this window since corrective action takes a finite time to be reflected in Settlements as it needs to be completed by the NHHDC, sent to the Non-Half Hourly Data Aggregator (NHHDA), processed by the NHHDA, sent to the Supplier Volume Allocation Agent (SVAA) and processed by the SVAA. |
Volume in Compensatory Period | The Meter Advance between the Error freezing reading and the Error Correcting Reading. |
Volume in Error Period | The Meter Advance between the last valid reading before the Error Period and the Error freezing reading. |
Ref | Action |
4.14.4.1 Mandatory Step | A Deemed Meter Reading, D1, should be calculated in the RF Window to freeze the error that has already crystallised. This shall be calculated using the actual, valid Meter register reading, A1 and the EAC / AA that crystallised in the RF117 for the Deemed Meter Advance Period starting on the date that the realistic reading A1 was obtained and ending on the date for which D1 was deemed. D1 and A1 may then be used to calculate an AA between D1 and A1. This AA will be the same value as the AA that has already crystallised in the period between A1 and D1. |
4.14.4.2 Mandatory step | If there are any invalid Meter readings in the fluid period, these should be withdrawn. |
4.14.4.3118 Optional step | If there is a second actual reading in the fluid period (A2) an AA can be calculated between A1 and A2. Use this to deem a correcting read (D2) for a date as long after the date of the error freezing read as is practical (ideally 60 WD or longer, if possible). The Deemed Meter Advance Period starts on the date of A1 and ends on the day before the Date of D2. |
4.14.4.4 Mandatory step if 4.14.4.3 not completed or there is no valid actual reading A2, otherwise optional | If there is no valid Actual reading (A2) in the fluid period, a realistic reading, D3, should be generated in the fluid period, for a Settlement Date as long after the date of the error freezing reading as is practical (ideally 60 WD or longer, where possible). This should be a Deemed Meter Reading (created from the previous actual, valid Meter register reading, A1 and an EAC that is representative of demand for that Metering System (i.e. a previous valid EAC) or, if not available, an initial (class average) EAC). |
4.14.4.5 Mandatory step | An AA should be calculated between either D1 and D2 or D1 and A2 or D1 and D3. If the AA has been calculated between D1 and D2, a second AA should be calculated between D2 and A2. |
4.14.4.6 Mandatory step | If the deeming process has created a negative forward EAC, this will be replaced by a replacement EAC in accordance with Appendix 4.5.2e. |
4.14.4.7 Optional step | If the forward EAC is demonstrably inconsistent with normal generation or demand for that Metering System and is likely to lead to failure to validate subsequent readings, the EAC going forwards from A2, D2 or D3 may be replaced with a realistic EAC (i.e. an EAC that has been based on a previous valid AA or, if none are available, an initial (class average) EAC). Please note that an EAC should only be replaced where no later readings exist that would allow for the calculation of a further AA that would bring the EAC back into line with previous valid demand or generation trends. Any replacement EACs should be subject to a robust audit process to identify how the replacement EAC was derived. |
MSID;
Supplier Id;
SSC;
Profile Class;
GSP Group;
Energisation Status;
Settlement Date of the start of the Error Period (i.e. date of last valid reading prior to Error freezing reading);
Settlement Date of Error freezing reading;
Settlement Date of Error Correcting Reading;
For each Settlement Register:
TPR;
Volume in Compensatory Period (i.e. Meter Advance between Error freezing reading and Error Correcting Reading);
Volume in Error Period (i.e. Meter Advance between start of Error Period and Error freezing reading);
Correct Volume (i.e. Meter Advance between start of Error Period and Error Correcting Reading);
Forward looking EAC following application of GVC (see note below);
Replacement EAC indicator (see note below);
Date GVC undertaken; and
Rationale for Change (optional).
MSID;
Supplier Id;
SSC;
Profile Class;
GSP Group;
Energisation Status;
Settlement Date of the dummy meter exchange;
Meter Multiplier;
CT Ratio;
For each Settlement Register:
o TPR;
o The final Meter reading;
o The initial Meter reading;
Date dummy meter exchange undertaken; and
Rationale for Change (optional).
has received from the NHHDC at least two D0004 ‘Notification of Failure to Obtain a Reading’ data flows, which are at least 75 calendar days apart and not more than 215 calendar days apart, with the J0024 ‘Site Visit Check Code’ data item populated with code 02 ‘Site not Occupied’;
and has not received any D0004s with the J0024 data item populated with anything other than 02, 18 ‘Unsafe Premises’, 19 ‘ Call not made on routine visit, 20 ‘No Access’ or ’28 ‘Unable to gain access due to insufficient address details’ in the interim; and
has not received any Meter register readings for that Metering System in the interim.
retains all Daily Profile Coefficient files used to calculate EAC/AA and Deemed meter advances, including those subsequently replaced by revised data;
Provides a means of archiving Daily Profile Coefficients and Smoothing Parameters once the Final Reconciliation Volume Allocation Run has taken place for that Settlement Day.
inaccuracy of data entry;
Meter readings not in line with historical/expected trends;
Meters which have not had a physical reading within the minimum period established by the BSC;
Identification of Metering System Number’s which are “dormant” i.e. not currently in use.
Serial | Sender | Process | Sub-Process | Recipient | Performance Measure | Service Levels | Reporting Method |
NC11 | Old NHHDC | 1.3 Registration Obligations | Missing NHH Meter Reads & History from Old NHHDC to New NHHDC | New HHDC | D0010 and D0152 missing | 100% issued to New NHHDC within 15 WD of New NHHDC EFD4 | [New NHHDC] |
‘RCAMR’ (Remotely Configurable Automated Meter Reading);
‘NCAMR’ (Non-Remotely Configurable Automated Meter Reading); or
‘RCAMY’ (Remotely Configurable Automated Meter Reading with Remote Shutdown Capability)
1 Part of the solution for CP1132 was delivered as part of the SVA November 05 Release.
2 CP1325 was implemented as part of the November 2010 Release on 01 November 2010
3 P257 was implemented on 04 November 2010
4 CP1334 was implemented as part of the June 2011 Release on 01 July 2011
5 Meter readings is a more generic requirement that includes Maximum Demand Indicators and other reading information that is not covered by the term Meter register reading. Only Meter register readings are required for Settlement purposes. Other readings may be required by Suppliers, LDSOs, NHHDCs and SVA MOAs.
6 The NHHDC system will manage both positive and negative AA/EAC values.
7 This requirement is to be met through software and data transfer controls and not by performing individual checks on a per-Metering System basis
8 Normally a single file (type 1 file) will be loaded for each Settlement Day, which will invalidate any previous data for that Settlement Date. However, the AA/EAC system will also support the loading of files for up to 2 years (type 2 file), in order to allow for the NHHDC being appointed to a SVA MS in another GSP Group, which will not invalidate any previous data.
9 The Supplier will state the class and type of SVA MS required and the data collection period for each SVA MS (for smart Meters, the Supplier will notify the NHHDC if the Metering System has a smart Meter using the Contract Reference (or by other means, as agreed). The NHHDC shall immediately notify the Supplier if these details are not sufficient to collect metering data
10 Whenever installing new, replacement and re-configured NHH meters or carrying out work requiring the re-registration of the metering system, the SVA MOA shall ensure that the meter registers are clearly identified and that the Meter Register ID (J0010) used in all relevant Data Transfer Network data flows (e.g. D0149 and D0150) clearly identifies the registers on the metering asset read. See REC Metering Operations Schedule for details.
11 Manual rejection solutions agreed by both the Supplier and NHHDC may be used in place of the D0310 flow.
12 If more than one Meter register reading is provided, the NHHDC shall process and use the first reading provided.
13 Where a bulk change of agent is being initiated, BSCP513 must have been completed prior to triggering this process.
14 The Supplier will inform the SVA MOA that the NHHDC has been appointed, via D0148 Notification of Change to Other Parties, and this notification will take place prior to step 3.2.3.4.
15 The old NHHDC will retain responsibility for the MSID until all instructions generated have been accepted and applied by the NHHDA.
16 The old NHHDC will send the meter register reading and associated EAC/AA history on request via a D0170, irrespective of whether a ‘Termination of Appointment or Contract by Supplier’ (D0151) flow has been received from the Supplier. Where no D0151 flow has been received, the de-appointment date can be derived from the ‘Date Action Required By’ (J0028) data item on the D0170 flow.
17 If the old NHHDC receives Meter register reading(s) from the SVA MOA after history has been passed to the new NHHDC, then the old NHHDC will manually inform the SVA MOA that the Meter register reading(s) will need to be sent by the SVA MOA to the new NHHDC.
18 The Supplier will provide this data either directly or via the old NHHDC.
19 The Supplier will notify all other parties that need to know of change of SVA MOA.
20 The relevant NHHDAs will include all the NHHDAs that were appointed during the NHHDCs period of responsibility.
21 In this instance, no D0019 is sent to the Supplier (as this will already have been provided).
22 Refer to Appendix 4.4 - – Change of Supplier Activities.
23 Note that if there is also a concurrent Change of SVA MOA and/or NHHDA, and the Supplier waits for all D0011 flows before sending a D0148, the New Supplier shall send the D0148 within 1 WD of the receipt of all applicable D0011 flows.
24 The process for DCC serviced NHH Metering Systems may also be used, by agreement between the new and old Supplier, for non-DCC Metering Systems which have been installed in compliance with the Smart Metering Equipment Technical Specifications.
25 The old NHHDC will send the meter register reading and associated EAC/AA history on request via a D0170, irrespective of whether a ‘Termination of Appointment or Contract by Supplier’ (D0151) flow has been received from the Supplier.
26 The old NHHDC should always send the latest valid set of Meter readings, together with the EAC value(s) calculated from those Meter reading(s).
27 The CoS reading is assumed to be correct by the Old Supplier, until the Old Supplier disputes the CoS reading.
28 An old Supplier Estimated reading may not be provided by the new Supplier to the new NHHDC earlier than SSD+5.
29 If there are other non-CoS readings dated after the new NHHDC appointment, which have been validated and are invalid, the new NHHDC will send the invalid Meter register reading(s) via the D0010 Meter Readings data flow. The “Reading Type” will not be flagged as “A – Actual Change of Supplier Read”.
30 This data flow is used for both valid and invalid readings produced from the Change of Supplier process.
31 This includes all Meter register readings successfully validated during the CoS process, including the CoS reading (with the CoS “Reading Date & Time” set to the actual date of the CoS reading as opposed to SSD).
32 This data flow only includes the CoS reading. The “Reading Date & Time” will be set to Effective from Settlement Date {REGI}.
33 Where a deemed reading is to be generated for a coincident Change of Supplier and Change of Data Collector, this deemed reading must be calculated using the historical data provided from the old NHHDC provided this is available and / or the PoS reading.
34 The NHHDC should clearly indicate in the D0170 that a D0311 is expected in return.
35 The NOSI flow may contain the Old Supplier’s Last EAC Details and / or the Last Actual or Customer Register reading. If the NOSI flow contains an Old Supplier’s Estimated CoS Reading this must not be used by the new NHHDC.
36 For domestic premises only, the new Supplier will forward the NOSI flow received from the old Supplier, which may or may not contain the EAC Details and Last Actual or Customer Register Reading. If the old Supplier failed to provide a NOSI flow, the new Supplier should indicate this by sending an ‘empty’ NOSI flow.
37 This data flow only includes the CoS reading. The “Reading Date & Time” will be set to SSD.
38 The Supplier may choose to raise a dispute where, in the Supplier’s view, there is difference of more than 250kWh from the original CoS reading.
39 As a result of agreeing a revised CoS reading, the new NHHDC will withdraw the original CoS reading.
40 If there is a difference between the original CoS Meter reading, deemed to SSD, and the proposed replacement CoS reading of less than 250 kWh, the NHHDC will accept the originally proposed CoS reading for use in Settlements.
41 Revised AA/EAC values will be calculated as a result of amending the CoS reading.
42 Upon receipt of the revised CoS reading, the old NHHDC will replace the previous CoS reading with the deemed CoS reading
43 The first attempt to obtain the SSD midnight read should be on SSD.
44 The DCC and DCC serviced Meters use UTC dates and times.
45 If SSD midnight register reading(s) retrieved, the Old Supplier will send the New Supplier the Total Cumulative and any active Time of Use Settlement Register reads from the Daily Read Log. The “Reading Type” will be flagged as “R – Routine”
46 The SSD midnight register reading(s) and instantaneous readings are taken at the point of configuration (whether or not there is a change of SSC).
47 The new Supplier should send readings for all 48 time of use registers, except for the second MSID of a twin element Meter which will only have four registers.
48 The New Supplier will re-date readings to SSD if taken up to SSD+5 WD. This may give rise to a discrepancy with a midnight SSD reading(s) taken by the Old Supplier. The Old Supplier should make allowances for such discrepancies before raising a query about the CoS reading.
49 When a Supplier sends readings to its NHHDC, the BSC Validation Status in the D0010 is set to ‘U’ (for ‘not validated’). This practice will apply equally to readings from smart Meters sent from one Supplier to another.
50 Irrespective of whether there has been a change to the Settlement configuration, this reading should be sent to the old Supplier and new NHHDC as read type “I”.
51 The instantaneous readings taken by the new supplier and passed to the old Supplier should be used by both Suppliers as the CoS reading, subject to validation by each NHHDC.
52 It is unlikely that the New NHHDC would have cause to invalidate a reading from the smart Meter (unless there is a register mapping issue). It is expected that this would be resolved via a dialogue between Supplier and NHHDC. In the unlikely event that validation identifies an issue with the reading from the smart Meter, the Supplier may issue a further request to the DCC.
53 The order of precedence is as follows: Remote reading, SVA MOA final, NHHDC, Customer own reading.
54 Note that if there is also a concurrent Change of SVA NHHMOA and/or NHHDA, and the Supplier waits for all D0011 flows before sending a D0148, the New Supplier shall send the D0148 within 1 WD of the receipt of all applicable D0011 flows.
55 The old NHHDC will send the meter register reading and associated EAC/AA history on request via a D0170, irrespective of whether a ‘Termination of Appointment or Contract by Supplier’ (D0151) flow has been received from the Supplier.
56 The old NHHDC should always send the latest valid set of Meter readings, together with the EAC value(s) calculated from those Meter reading(s).
57 This process can also be used where there is only a CoMC, not a coincident CoS and CoMC.
58 For the Change of Measurement Class process for Supplier-serviced Metering Systems, refer to sections 3.3.16 to 3.3.19.
59 In addition the old Supplier will inform its other Agents of their de-appointments (via D0151 Termination of Appointment or Contract by Supplier) and they also become de-appointed on SSD-1.
60 Where the old Supplier wishes to query the final Meter register reading(s) they shall contact the old NHHDC and the old NHHDC shall endeavour to resolve the query.
61 An initial Meter reading is required for a co-incident CoS and CoMC. It is optional for a CoMC only.
62 By 10 Working Days before the Final Reconciliation Run for the relevant Settlement Date if no concurrent Change of Supplier.
63 It is necessary for settlement purposes to identify a SVA MS as energised or de-energised. Where a SVA MS consists of more than one Meter, it will be considered energised if at least one of its meters is energised.
64 If the final Meter reading is deemed, and subsequently the Metering System is energised and an initial Meter register reading is obtained, the initial Meter register reading shall be substituted as the final Deemed Meter Reading provided that the Deemed Meter Reading for the date of the de-energisation has not been included in an RF run, in accordance with Appendix 4.5.
65 If necessary the Supplier and NHHDC agree revised terms for retrieval and processing of data.
66 Settlement Registers must not ‘double count’ electricity. If two physical registers record the same consumption, then the NHHDC must perform a process of differencing.
67 On change of Profile Class for a SVA MS, a class average EAC will be submitted in preference to an EAC calculated from the AA for the Meter Advance Period spanning the change of Profile Class. An EAC will not be calculated if the Profile Class has changed during the Meter Advance Period.
68 A change of Meter due to safety reasons may lead to a different type of Meter being put in. This would require the SVA MOA to determine a permanent solution, in conjunction with the NHHDC as necessary.
69 With reference to 3.3.7.1, whenever installing new, replacement and re-configured NHH meters or carrying out work requiring re-registration of the metering system, the SVA MOA shall ensure that the Meter registers are clearly identified and that Meter Register Id (J0010) to be used in all relevant DTN Data Flows (e.g. D0149 & D0150) clearly identifies the registers on the metering asset read. See Retail Energy Code Metering Operations Schedule for details.
70 When a fault is reported by the SVA MOA, the collection timetable will be updated in time to ensure that faulty data is not collected and passed into the Settlement process. Following resolution of the fault, the data collection timetable will be updated to ensure that actual data is collected within the collection period for the SVA MS.
71 If the period of the fault is not known then the SVA MOA will notify the NHHDC that this period cannot be determined by the SVA MOA.
72 The NHHDC must ensure that there is no change to the original reading collected from the SVA MS as a result of SVA MS faults notified by the SVA MOA. Invalidated readings must be retained for reference.
73 Where the NHHDC receives notification of a fault from someone other than the SVA MOA, the NHHDC will report the fault to the SVA MOA.
74 The Supplier and LDSO will withdraw all subsequent Meter register reading(s) received after the period of the fault until notified of the next valid Meter register reading by the NHHDC.
75 If the NHHDC receives a final Meter register reading for the removed SVA MS the NHHDC will record but will not use this Meter register reading in Settlement as the NHHDC will deem an advance for the period of the fault.
76 The NHHDC must ensure that there is no change to the original reading collected from the SVA MS as a result of SVA MS faults notified by the SVA MOA. Invalidated readings must be retained for reference.
77 The Supplier and LDSO will withdraw all subsequent Meter register readings received from the NHHDC.
78 Suppliers shall have the choice on whether or not they wish their NHHDC to follow this process and withdraw the Meter reading.
79 The initial Meter reading at the start of the Long Term Vacant period to be withdrawn must not have passed the Final Reconciliation Run.
80 Valid reasons for requiring a Meter register reading are:
- the NHHDCs system constraints;
- the change of Profile Class requires a change of SSC or change of Meter or reprogramming of the Meter; or
- as a result of a Supplier request.
81 The NHHDC will indicate there has been a change of Profile Class by sending a D0010 Meter Reading to the Supplier. In particular the following fields will be completed by the NHHDC: ‘Additional Information’ field - the NHHDC will confirm that the flow is a Profile Class change flow; if Meter register reading obtained, additionally the ‘Reading Type’ field will be completed - the NHHDC will select the ‘s’ - for ‘Special’ value. This combination of data will enable the Supplier to identify that this is a change of Profile Class flow.
82 The NHHDC must ensure that initial sets of Daily Profile Coefficients are loaded into the AA/EAC system in ascending Settlement Date order (i.e. a file must already have been loaded for the previous Settlement Day) and in correct version sequence (although version numbers may not be sequential) for any file type/GSP Group combination.
83 If the CoS business event is triggering this process, then the old NHHDC will provide an AA up to and including SSD-1 and the new NHHDC will provide an EAC from SSD.
84 On request from the Supplier, the NHHDC shall replace any residual negative EACs reported by the NHHDA with positive values in accordance with 4.5.2 r).
85 The NHHDC will be required to store and retrieve the smoothing parameter for use in calculating the EACs. The NHHDCs system must validate that the value provided for the smoothing parameter is a positive number.
86 The EAC value sent to the NHHDA and Supplier will normally be that calculated in step 3.3.11.3, but may be substituted in accordance with paragraph 4.5.2(e) or step 4.14.4.7.
87 This may be an old NHHDC in the case where there has been a change of NHHDC.
88 The NHHDC will send the data (AA and or EAC) only to their respective Supplier / NHHDA.
89 Or if the 20th is not a working day, the next working day.
90 If specified by the Supplier, the report may contain only the valid AAs from the exception log.
91 The NHHDC will send the exceptions to their respective supplier.
92 Supplier may be notified of Incorrect Register Mapping by other participants.
93 The Supplier will liaise with the SVA NHHMOA and NHHDC to determine what action is required next.
94 D0004 ‘Notification of Failure to Obtain a Reading’ with the J0024 data item populated with Site Visit Check Code 02 ‘Site not occupied’.
95 This is an optional process step which can be followed if the Supplier identifies a site re-entering the LTV process having previously fallen out of the process due to a warrant read being obtained
96 The timescales, the method of communicating the report, the format of the report and any extra details to be included should be agreed between the Supplier and LDSO.
97 If the Supplier does not have a Meter reading for the date that the site ceased to be Long Term Vacant, the Supplier will only send the D0052 to the NHHDC containing a non-zero EAC for the site and the Effective From Date of that EAC.
98 The Code specifies that the Supplier may choose to use the initial (class average) EAC for a site that has previously been treated as Long Term Vacant, or an EAC that the Supplier reasonably believes is most likely to represent the rate of generation or demand for that Metering System. If the Supplier does not send a D0052 alongside the D0010, the NHHDC should pass the EAC calculated in accordance with Appendix 4.9 into Settlement.
99 An affected MSID is any MSID that an LDSO disconnects due to a Demand Control Event. The period of disconnection should match the length of the DCE as reported by NETSO in its Demand Control Imminent Notification(s), regardless of the actual period of disconnection.
100 Whilst the P0238 is sent by the LDSO to the BSCCo, it should be generated by the LDSO as though it is to be sent direct to Party Agents, i.e. the ‘MPID To’ in the header should reflect the various agents that are intended to receive the file.
101 The NHHDC will inform the Supplier if the SVA MS equipment is inadequate or that insufficient data about a SVA MS is available. The Supplier will investigate the situation and ensure that the SVA MS and the information provided are adequate. Where a SVA MS is de-energised the NHHDC shall make visits to the site concerned every 12 months. The NHHDC shall provide the latest meter readings to the LDSO for all SVA Metering Systems for which it is responsible, as soon as possible and on a regular basis.
102 Where a D0052 Affirmation of Metering System Settlement Details, electronic or otherwise, is received from UMSO or Supplier for an Unmetered Supply, this value must be sent to the NHHDA on a D0019 Metering System EAC/AA Data for use in Settlement. The D0052 Affirmation of Metering System Settlement Details received from UMSO should be used in preference where available.
103 The NHHDC will always apply the ‘Meter Register Multiplier’ and the ‘Pulse Multiplier’, as provided by the SVA MOA in the D0150 Non-Half Hourly Meter Technical Details data flow.
104 Prepare valid data reports including active, reactive and maximum demand readings.
105 If fault identified covers a CoS, the CoS reading and EAC shall be used and sent to the NHHDA. However, if the fault covers the final Stage 2 Run, a class average EAC will be used and sent to the NHHDA.
106 On request from the Supplier, the NHHDC shall replace any residual negative EACs reported by the NHHDA with positive values in accordance with 4.5.2 r).
107 Please note that, whilst Gross Volume Correction is usually requested by the Supplier, the NHHDC can initiate Gross Volume Correction, although only with the approval of the relevant Supplier or Suppliers. Such approval can be obtained on per-instance or a delegated authority basis, as agreed with the Supplier.
108 If no valid actual readings are available but a valid Deemed reading is available, this reading can be used instead.
109 Refer to section 4.9.
110 If the old NHHDC is unable to validate meter reading(s) during the Change of Non-Half Hourly Data Collector business event, the old NHHDC will identify that the meter reading(s) has not been validated in the appropriate data flow.
111 The meter reading history will take precedence because this relates to reading data that has undergone validation and is less likely to be inaccurate than the AA/EAC data because this is calculated data.
112 There are no dates associated with the tolerance values therefore there is no requirement for the NHHDC to retain a history.
113 Revised EACs will only fall outside tolerances as the result of erroneously large AAs, so validation of EACs is superfluous.
114 The NHHDC will retain an audit trail of any Meter register reading which is withdrawn.
115 Where a D0052 is sent to notify the NHHDC of a change of Profile Class a D0150 will not be sent by the SVA MOA. In the case of Unmetered Supplies a D0150 will not be sent by the SVA MOA.
116 A “dummy meter exchange” involves the use of Initial and Final Meter readings to effectively re-start consumption histories even though no actual, physical change of Meter has taken place.
117 This may involve reference to D0095 Non-Half Hourly Data Aggregation Exception Report and / or D0023 Failed Instructions data flows to determine if EACs / AAs have been rejected or default EACs applied.
118 Note that if there has been a discontinuity in the effective Meter reading (e.g. due to a Meter fault or incorrect standing data or processing) within the crystallised period that was not previously taken into account, the corrective Meter Advance (and AA) will need to be adjusted to allow for this.