Balancing and Settlement Code
BSC PROCEDURE
BM Unit Registration
BSCP15
Date:
|
Intellectual Property Rights, Copyright and Disclaimer The copyright and other intellectual property rights in this document are vested in Elexon or appear with the consent of the copyright owner. These materials are made available for you for the purposes of your participation in the electricity industry. If you have an interest in the electricity industry, you may view, download, copy, distribute, modify, transmit, publish, sell or create derivative works (in whatever format) from this document or in other cases use for personal academic or other non-commercial purposes. All copyright and other proprietary notices contained in the document must be retained on any copy you make. All other rights of the copyright owner not expressly dealt with above are reserved. No representation, warranty or guarantee is made that the information in this document is accurate or complete. While care is taken in the collection and provision of this information, Elexon Limited shall not be liable for any errors, omissions, misstatements or mistakes in any information or damages resulting from the use of this information or action taken in reliance on it. |
Version | Date | Description of Changes | Changes Included | Mods/ Panel/ Committee Refs |
1.0 | Code Effective Date | Designated version | n/a | n/a |
2.0 | 30/11/00 | Work outstanding at Go Active, resolution of inconsistencies, inclusion of consultation comments. | 223, 243 | 08/009 |
3.0 | 13/08/02 | Change Proposals for BSC Systems Release 2 | CP521, 528, 567, 568, 546, 726, 782 | ISG 16/166, ISG 18/193 SVG 19/233 |
4.0 | 24/06/03 | Change Proposals for CVA Programme June 03 Release | CP 749, 761, 821, P106 |
|
5.0 | 01/08/03 | Approved Modification P62 | P62 | P62 48/003 |
6.0 | 12/09/03 | Approved Modification P82 and P100 for CVA Programme Nov 03 Release | P82 P100 | P82 54/006, P100 57/007 |
7.0 | 27/02/04 | Approved Modification P123 for CVA Programme Feb 04 Release | P123 | P123 66/006 |
8.0 | 15/03/04 | Change Proposal CP1027 | CP1027 | ISG37/414 |
9.0 | 30/06/04 | CVA Programme June 04 Release. | CP971 CP944 CP1030 P82 Removal | ISG40/003 SVG40/004 |
10.0 | 23/02/05 | CVA Programme Feb 05 Release | BETTA 6.3; CP1015, P159, CP1040, CP1091 |
|
11.0 | 02/11/05 | CVA Programme Nov 05 Release. | CP1108 P192 | ISG52/003 P96/004 |
12.0 | 28/06/06 | June 06 Release | P190 CP1154 | ISG64/001 SVG64/002 |
13.0 | 28/02/08 | February 08 Release | CP1201
CP1231 | ISG81/01 SVG81/01 ISG84/01 SVG84/02 |
14.0 | 06/11/08 | November 08 Release | CP1239 | ISG88/01 SVG88/02 |
15.0 | 20/04/09 | P216 Release | P216 | ISG97/02 SVG97/08 |
16.0 | 25/06/09 | June 09 Release | P215 | 23/04/2008 (OFGEM) |
17.0 | 20/11/09 | P237 | P237 | Panel 160/04 |
18.0 | 27/01/10 | Modification P240 | P240 | Panel |
19.0 | 04/11/10 | November 10 Release | CP1330 | ISG112/01 SVG112/03 |
20.0 | 23/02/12 | February 2012 Release | P268 | Panel 186/04 |
|
|
| P269 | Panel 186/05 |
21.0 | 26/06/14 | June 2014 Release | CP1403 | ISG154/01 SVG157/05 |
22.0 | 01/08/14 | Electricity Market Reform | ORD005 | Directed by the Secretary of State |
23.0 | 25/06/15 | June 2015 Release | P310 | ISG169/05 SVG172/02 |
24.0 | 23/02/17 | February 2017 Release | P326 Self-Governance | SVG190/02 ISG188/05 |
25.0 | 29/06/17 | June 2017 Release | P350 | ISG194/02 SVG196/03 |
26.0 | 22/02/18 | February 2018 Release | CP1493 | ISG200/10 SVG202/02 |
27.0 | 28/02/19 | February 2019 Release | P344 | Panel 284C/01 |
| 28/02/19 | February 2019 Release | CP1510 | ISG211/06 SVG214/02 |
| 28/02/19 | February 2019 Release | P359 | ISG212/03 SVG215/03 |
28.0 | 29/03/19 | March 2019 Standalone Release | P369 | Panel 285/12 |
29.0 | 27/0/19 | June 2019 Release | P364 | Panel 288/08 |
30.0 | 07/11/19 | November 2019 Release | P386 Self-Governance | Panel 291/05 |
| 07/11/19 | November 2019 Release | P389 Self-Governance | Panel 294/04 |
31.0 | 27/02/20 | February 2020 Release | P394 Self Governance | Panel 297/07 |
32.0 | 30/06/22 | 30 June 2022 Release | P375 | Panel 309/06 |
33.0 | 23/02/2023 | 23 February 2023 Release | P376 | P314/06 |
New registration of Primary BM Units;
De-registration of Primary BM Units;
Changes in the Final Physical Notification (FPN) flag status;
Registration of Seasonal Estimates of the Maximum Positive Magnitude and Maximum Negative Magnitude Primary BM Unit Metered Volume;
Application for Exemptable status for a Generating Plant and Exempt Export status for the associated Primary BM Unit(s), including election of the Production / Consumption Status for the Exempt Export Primary BM Unit(s) by the Lead Party;
Change of Production / Consumption Status for an Exempt Export Primary BM or Secondary BM Unit by the Lead Party;
Termination of Exemptable status for a Generating Plant and the Exempt Export status of the associated Primary BM Unit(s);
Mid-Season Changes of the Maximum Positive Magnitude and Maximum Negative Magnitude Primary BM Unit Metered Volume;
Monitoring of BM Unit Metered Volumes for breaches of Generation Capacity and Demand Capacity;
Change of Central Volume Allocation (CVA) Primary BM Unit Lead Party;
Transfer of Supplier Identifier (ID); and
Notification of Switching Group1.
New registration of Secondary BM Units;
De-registration of Secondary BM Units
Detailed notification of ‘registration’ or reconfiguration of a Primary BM Unit (except a Non-Standard Primary BM Unit or Additional Primary BM Unit) at least 30 Working Days (WD) prior to the Effective From Date;
60 WD notification of registration or reconfiguration of a Non-Standard Primary BM Unit. A longer timescale is required in order that the application may be properly considered by BSCCo, the NETSO and the Panel. The Party should advise BSCCo of any such applications at the earliest opportunity such that indicative registration timescales and Effective From Dates may be discussed.
15,18 WD notification of registration of Additional Primary BM Unit, unless FPN flag is set to ‘yes’ where 30 WD notification may be needed (see section 1.6).
15 WD notification of registration of Secondary BM Unit;
20 WD notification of de-registering Primary BM Unit (30 WD for a Base Primary BM Unit) prior to proposed Effective To Date;
20 WD notification of de-registering Secondary BM Unit prior to proposed Effective To Date;
New Suppliers notified to Supplier Volume Allocation (SVA) at least 30 WD prior to the Effective From Date;
5 WD notification of transfer of Directly Connected Demand Primary BM Units, if the criteria set out in section 3.13 are satisfied;
5 WD notification of Change of CVA Primary BM Unit Lead Party , if the criteria set out in section 3.13 are satisfied; and
1 WD notification of transfer of Supplier ID process (Change of SVA Primary BM Unit Ownership).
Proving Test Requirements for Central Volume Allocation Metering Systems | |
CVA Meter Operations for Metering Systems Registered in CMRS | |
Registration of Metering System for Central Volume Allocation | |
Registration of Transmission System Boundary Points, Grid Supply Points, GSP Groups & Distribution Systems Connection Points | |
Registration of Trading Units | |
Metering Dispensations | |
Authorisations | |
Registration of Parties and Exit Procedures | |
Transfer of Registration of Metering Systems between CMRS and SMRS | |
Submission of ECVNs and MVRNs | |
Registration of Meter Aggregation Rules for Volume Allocation Units | |
Production, Submission, Audit and Approval of Line Loss Factors | |
Changes to Market Domain Data | |
SVA Metering System and Asset Metering System Register |
Apply to register each Power Park Module as a separate Primary BM Unit; or
Apply to register a single Primary BM Unit for some or all of the Offshore Power Park Modules (a ‘Combined Offshore BM Unit’).
Acronym | Expression |
AMSID | Asset Metering System Identifier |
AMVLP | Asset Metering Virtual Lead Party |
BMRA | Balancing Mechanism Reporting Agent |
BSCCo | Balancing and Settlement Code Company |
CDCA | Central Data Collection Agent |
CFD | Contract For Difference |
CFDSSP | Contract for Difference Settlement Services Provider |
CM | Capacity Market |
CMRS | Central Meter Registration Service |
CRA | Central Registration Agent |
CoPBLP | Change of Primary BM Unit Lead Party |
CVA | Central Volume Allocation |
DNC | Declared Net Capacity |
EDL | Electronic Dispatch Logging |
EDT | Electronic Data Transfer |
EFD | Effective From Date |
ETD | Effective To Date |
FPN | Final Physical Notification |
GSP | Grid Supply Point |
IA | Interconnector Administrator |
ID | Identifier |
LDSO | Licensed Distribution System Operator |
MDD | Market Domain Data |
MSID | Metering System ID |
NETSO | National Electricity Transmission System Operator as the holder of the Transmission Licence and any reference to "NETSO", "NGESO", "National Grid Company" or "NGC" in the Code or any Subsidiary Document shall have the same meaning. |
P/C | Production / Consumption |
SEV | Settlement Expected Volume |
SMRA | Supplier Meter Registration Agent |
SPD | Settlement Period Duration |
SVAA | Supplier Volume Allocation Agent |
SVA | Supplier Volume Allocation |
TSBP | Transmission System Boundary Point |
VAU | Volume Allocation Unit |
VLP | Virtual Lead Party |
WD | Working Day |
AMSID Pair | One Import AMSID and, where applicable, one Export AMSID whose Half Hourly Asset Metering Systems are situated behind the Boundary Point for the purposes of offering Balancing Services. |
Baselined BM Unit | A BM Unit that has at least one MSID Pair registered that will have its expected energy flows calculated through a Baseline Methodology. |
Contracted LDSO | The Contracted LDSO is an LDSO who has the obligation to provide the SMRS service to the Registrant of the Metering System. |
Control Point | As defined in the Grid Code. |
Declared Net Capacity | In relation to a generating station, it is the output of that station to the Total System multiplied by the relevant following constant:
This term is used in statutory instrument 2001 No. 3270 The Electricity (Class Exemptions for the Requirement for a Licence) Order 2001. |
Effective From Date | The Settlement day from which the Primary and Secondary BM Unit is allowed to trade. |
Effective To Date | The final Settlement day that the Primary and Secondary BM Unit is allowed to trade. |
GC or DC Breach | The positive or negative value of QMij for the BM Unit divided by SPD has exceeded the GC by the GC Limits or has exceeded the DC by the DC Limits. The GC or DC Limits are defined in Section K3.4.3A |
MSID Pair | One Import MSID and, where applicable, one Export MSID whose Half Hourly Metering Systems are situated at a single Boundary Point for the purposes of offering Balancing Services. |
NETSO Commission Date | The date from 0000 hours on which the BM Unit can trade through the NETSO systems. |
Nominated Licensed Distribution System Operator | The Nominated LDSO is the LDSO which has obligations to submit the GSP Group Metered Volume Aggregation Rules. |
Non-Standard Primary BM Unit | A configuration of Plant and Apparatus determined by the Panel to be a single Primary BM Unit in accordance with BSC Section K3.1.6. |
Operational Metering | The metered data associated with the Primary and Secondary BM Unit which is utilised by the NETSO. |
Production / Consumption (P/C) Flag | The flag within CRA systems which records either the fixed P/C Status elected for an Exempt Export Primary BM Unit by the Lead Party, or the fixed P/C Status allocated to an Interconnector Primary BM Unit or the fixed P/C Status elected for a Secondary BM Unit by the Virtual Lead Party or Asset Metering Virtual Lead Party. |
Self-Service Gateway | An online portal, accessible through the BSC Website, that allows authorised users to provide and maintain registration data, including (but not limited to) the data defined in this BSCP. |
Standard Primary BM Unit | A configuration of Plant and Apparatus that forms one of the single Primary BM Units set out in BSC Section K3.1.4. |
Supplier ID Transferee | Trading Party that will become responsible for the relevant Supplier ID. |
Supplier ID Transferor | Trading Party Transferring the relevant Supplier ID. |
Trading Agent | The Balancing Mechanism Lead Party or their Agent, registered as submitting data to or receiving data from the NETSO, in respect of Primary and Secondary BM Units assigned to them. |
Trading Point | A commercial and, where so specified in the Grid Code, an operational interface between a user and the NETSO, which a user has notified to the NETSO. |
REF | WHEN | ACTION | FROM | TO | INPUT INFORMATION REQUIRED | MEDIUM |
3.1.1 | At least 60 WD prior to Effective From Date (in the case of Non-Standard Primary BM Units) If registering a Standard Primary BM Unit go straight to step 3.1.12 | If the Party does not believe the application meets the requirements for a Standard Primary BM Unit as set out in the Code or the Party requires a Non-Standard Primary BM Unit for another reason, submit application for Non-Standard Primary BM Unit by submitting a form or request via the Self-Service Gateway. Also submit electrical single line diagram(s) clearly showing the proposed configuration, the location of the Metering Equipment, in particular the Settlement current and voltage transformers (CTs/VTs) and CT/VT ratios4, and all existing Boundary Points and any System Connection Points at or near the proposed Boundary Point(s). 5, 6, 7 | Party | BSCCo | BSCP15/4.13 Application for Non-Standard Primary BM Unit signed by an authorised person registered as such using BSCP38. | Email / Self-Service Gateway |
3.1.2 | Following 3.1.1 | Check application for Non-Standard Primary BM Unit for completeness and compliance with requirements of BSC Section K3.1. | BSCCo |
| BSCP15/4.13 Application for Non-Standard Primary BM Unit. | Internal process |
3.1.3 | Where appropriate for Non-Standard Primary BM Unit | Where additional information or clarifications are required for a determination to be reached, request such information from the Party. | BSCCo | Party | Request for specific information. | |
3.1.4 | As required for Non-Standard Primary BM Unit and in the timescales required by BSCCo to meet Panel requirements | If request for more information received, provide requested information as agreed between BSCCo and the Party. | Party | BSCCo | Requested information. | |
3.1.5 | As soon as possible following 3.1.2 or 3.1.4 as appropriate | Send Non-Standard Primary BM Unit for comment on and agreement of the proposed configuration. | BSCCo | NETSO | BSCP15/4.13 Application for Non-Standard Primary BM Unit. | |
3.1.6 | Within 5WD of 3.1.5 | Provide comments on the proposed configuration and whether it is agreeable. | NETSO | BSCCo |
| |
3.1.7 | Following 3.1.6 if the NETSO does not agree with the proposed configuration | Notify Party that the NETSO does not agree with the proposed configuration and ask if the Party wishes to proceed with the Non-Standard Primary BM Unit application in its current form. | BSCCo | Party |
| |
3.1.8 | Following 3.1.7 | Advise BSCCo whether to proceed with the application or not. Go to 3.1.9 or back to 3.1.1 as appropriate. | Party | BSCCo |
| |
3.1.9 | Following 3.1.6 or 3.1.8 and following receipt of sufficient information in 3.1.1 and if appropriate 3.1.4 and to meet Panel timescales | Prepare and submit Panel paper for consideration. | BSCCo | Panel | Panel paper BSCP15/4.13 Application for Non-Standard Primary BM Unit Electrical single line diagram(s). | Internal process |
3.1.10 | At next convenient Panel meeting | Consider application and either approve the Non-Standard Primary BM Unit, defer the Non-Standard Primary BM Unit application pending more information, or reject the Non-Standard Primary BM Unit. | Panel | BSCCo | Panel decision. |
|
3.1.11 | Following Panel meeting for Non-Standard Primary BM Unit | Inform Party of Panel decision. Request further information if required. If further information required go back to step 3.1.9. | BSCCo | Party |
| |
At least 30 WD prior to Effective From Date | Submit Registration of Primary BM Unit form and, if not already submitted, an electrical single line diagram(s) showing the location of the Metering Equipment, in particular the Settlement current and voltage transformers (CTs/VTs) and CT/VT ratios11, and all existing Boundary Points and any System Connection Points at or near the proposed Boundary Point(s). 12, 13, 14 | Party | CRA | BSCP15/4.1, Registration of Primary BM Unit signed by an authorised person, registered as such using BSCP38. | Fax / Post / Email / Self-Service Gateway | |
3.1.13 | Within 1 WD of receipt of 3.1.12 | Acknowledge receipt of Registration of Primary BM Unit form | CRA | Party |
| Fax / Email / Post / Self-Service Gateway |
3.1.14 | At the same time as 3.1.13 | The CRA checks the following:
| CRA |
| As submitted in 3.1.2 | Internal Process |
3.1.15 | At the same time as 3.1.13 | Where the Primary BM Unit is embedded within a GSP Group, confirm with the SMRA and Party whether the Metering System was previously registered in SMRA, and if “Yes” ensure that the Effective From Date is such that it prevents dual or no registration of supply in accordance with BSCP68. | CRA | Party SMRA | Primary BM Unit Effective From Date. (Where the Primary BM Unit Effective From Date is such that it will have dual or no registration the Party should be informed to register the Primary BM Unit with a new Effective From Date.) | Fax / Email |
3.1.16 | At the same time as 3.1.13 | Inform CDCA, NETSO and BSCCo of the intended Primary BM Unit registration. | CRA | CDCA NETSO BSCCo |
| Fax / Email |
3.1.17 | At the same time as 3.1.13 | Where the Primary BM Unit is embedded within a Distribution System inform the Contracted LDSO of the registration. Where the Contracted LDSO is not the Nominated LDSO for the GSP Group, CRA should also inform the Nominated LDSO of the registration. | CRA | Relevant LDSO(s) | Primary BM Unit information including Effective From Date | Post / Fax / Email |
3.1.18 | At least 20 WD prior to Effective From Date (unless otherwise agreed by the BSC Panel) | For Embedded Primary BM Units, initiate the Line Loss Factor process (BSCP128) by submitting CVA LLFs for MSID | LDSO | BSCCo | CVA Long or Short Format data files in accordance with BSCP128 Appendix 5. Signed by an authorised person as per BSCP38 | Fax, post or email and Electronic Spreadsheet |
3.1.19 | Within 5 WD of 3.1.16 | Where the Party is applying to register 2 or more Offshore Power Park Modules as a Combined Offshore BM Unit, the NETSO shall confirm whether it determines that such a configuration is suitable to constitute a single BM Unit Primary BM Unit. | NETSO | CRA BSCCo | A statement as to whether the NETSO determines that the Party’s requested configuration of Offshore Power Park Modules is suitable to constitute a single Primary BM Unit | Fax / Email / Post |
3.1.20 | Within 5 WD of 3.1.16 and (if applicable) at the same time as 3.1.19 | The NETSO may object to the registration. | NETSO | CRA | A statement detailing the nature of the objection Where an objection cannot be resolved, the CRA shall escalate the objection to BSCCo | Fax / Email / Post |
3.1.21 | 15 WD prior to the Effective From Date | BSCCo to send data to CRA. CRA to register the Working Day Credit Assessment Load Factor (WDCALF), Non-Working Day Credit Assessment Load Factor (NWDCALF), Supplier Export Credit Assessment Load Factor (SECALF) and Transmission Loss Factor (TLF) data for the Primary BM Unit and ensure that this data is registered prior to the Effective From Date of the Primary BM Unit. | BSCCo | CRA | WDCALF, NWDCALF and SECALF data – Credit Assessment Load Factors (CRA-I011) Transmission Loss Factors (CRA-I029) | |
3.1.22 | 5 WD prior to Effective From Date | CDCA to confirm the following:
| CDCA | CRA | Metering System proving test results, Meter Aggregation Rules (Where confirmation has not been provided the Primary BM Unit registration shall remain pending.) | Email / Fax / Electronic |
3.1.23 | On or before Effective From Date | Provide Party and BSC Agents with registration reports. | CRA | Party
NETSO and BSCCo BSC Agents | Registration reports of data entered onto systems including Effective From Date – Registration Report (CRA-I014), Operations Registration Report (CRA – I020), BM Unit, Interconnector and GSP Group Data (CRA-I015). | Electronic |
REF | WHEN | ACTION | FROM | TO | INPUT INFORMATION REQUIRED | MEDIUM |
3.2.1 | At least 30 WD prior to Effective From Date | Submit Registration of Primary BM Unit form or information via the Self-Service Gateway. Inform the NETSO of Primary BM Unit registration | Party Party | CRA NETSO | BSCP15/4.1, Registration of Primary BM Unit signed by an authorised person, registered as such using BSCP38. | Fax / Email / Post / Self-Service Gateway Fax / Email |
3.2.2 | Within 1 WD of receipt of 3.2.1 | Acknowledge receipt of Registration of Primary BM Unit request | CRA | Party |
| Fax / Email / Post / Self-Service Gateway |
3.2.3 | At the same time as 3.2.1 | The CRA checks the following:
| CRA |
| As submitted in 3.2.1 | Internal Process |
3.2.4 | At the same time as 3.2.2 | Inform CDCA, the NETSO and BSCCo of the intended Primary BM Unit registration. | CRA | CDCA NETSO BSCCo |
| Fax / Email /Self-Service Gateway |
3.2.5 | Within 5 WD of 3.2.4 | The NETSO may object to the registration. | NETSO | CRA | A statement detailing the nature of the objection | Fax / Email / Post |
3.2.6 | 15 WD prior to the Effective From Date | BSCCo to send data to CRA. CRA to register the Transmission Loss Factor (TLF) data for the Primary BM Unit and ensure that this data is registered prior to the Effective From Date of the Primary BM Unit15. | BSCCo | CRA | Transmission Loss Factors (CRA-I029) | |
3.2.7 | On or before Effective From Date | Provide Party and BSC Agents with registration reports. | CRA | Party
NETSO and BSCCo BSC Agents | Registration reports of data entered onto systems including Effective From Date – Registration Report (CRA-I014), Operations Registration Report (CRA – I020), BM Unit, Interconnector and GSP Group Data (CRA-I015). | Electronic |
REF | WHEN | ACTION | FROM | TO | INPUT INFORMATION REQUIRED | MEDIUM |
3.3.1 | At least 30 WD prior to Effective From Date | Notification of a new Supplier or Supplier ID. (The requirement for 30WDs notice may be reduced if there is agreement between the CRA/BSCCo/Party/NETSO and that this date coincides with a MDD publication date.) | BSCCo | CRA | Supplier Name, Supplier ID and Effective From Date | Fax / Email / Self-Service Gateway |
3.3.2 | Upon notification of 3.3.1 | The CRA shall register Primary BM Unit identifiers, one for each GSP Group which shall be used for allocating SMRA consumption data for the Supplier or Supplier ID. | CRA |
| Notification of new Supplier or Supplier ID. | Internal Process |
3.3.3 | At the same time as 3.3.2 | Allocate each Base Primary BM Unit to the Base Trading Unit for the relevant GSP Group (and set the Base Trading Unit Flag for each Primary BM Unit).16, 17 | CRA |
| Creation of new Base Primary BM Units for each GSP Group | Internal Process |
3.3.4 | At the same time as 3.3.2 | Notify SVAA and BSCCo of the Base Primary BM Units registered. | CRA | SVAA BSCCo | BM Unit and GSP Group Data (CRA-I015) including Supplier ID, BM Unit IDs and the Effective From Date Registration Report (CRA-I014) (Where a Base Primary BM Unit will exceed the NETSO’s de minimis requirements to submit Physical Notifications the Party is required to notify the NETSO) | Electronic |
3.3.5 | On receipt of data in 3.3.4 | CRA to receive and register the Working Day Credit Assessment Load Factor (WDCALF), Non-Working Day Credit Assessment Load Factor (NWDCALF), Supplier Export Credit Assessment Load Factor (SECALF), and Transmission Loss Factor (TLF) data for the Primary BM Unit and to ensure that this data is registered prior to the Effective From Date of the Primary BM Unit. | BSCCo | CRA | WDCALF, NWDCALF and SECALF data – Credit Assessment Load Factors (CRA-I011)
Transmission Loss Factors (CRA-I029) | |
3.3.6 | Prior to the effective date of the Base Primary BM Units | Supplier to complete the Primary BM Unit registrations by providing the initial GC/DC values and FPN Flag and where appropriate the NGC Primary BM Unit Name. | Party | CRA | BSCP15/4.1, Registration of Primary BM Unit signed by an authorised person, registered as such using BSCP38. | Fax / Post / Email / Self-Service Gateway |
3.3.7 | On or before Effective From Date | Provide Party and BSC Agents with registration reports. | CRA | Party BSC Agents NETSO BSCCo | Standing data reports of data entered onto systems (CRA-I014, CRA-I015 and CRA-I020). | Electronic (Fax/Email to BSC Agents and BSCCo) |
REF | WHEN | ACTION | FROM | TO | INPUT INFORMATION REQUIRED | MEDIUM |
3.4.1 | As required, but before 3.4.2. | Initiate Market Domain Data (MDD) process (BSCP509) | Originator | BSCCo | Form BSCP509/01 & relevant part of entity forms document. | Fax / Email |
3.4.2 | At least 1518 WD prior to Effective From Date if FPN flag set to ‘no’, or 30 WD18 prior to Effective From Date if FPN flag set to ‘yes’ | Submit Registration of Primary BM Unit form19 or complete relevant sections of the Self-Service Gateway Effective From Date must be on or after the MDD Go Live Date. | Party | CRA | BSCP15/4.1, Registration of Primary BM Unit signed by an authorised person, registered as such using BSCP38.
Where a party wishes for a Settlement Expected Volume (SEV) to replace the FPN they will indicate that the BM Unit is a Baselined BM Unit in form BSCP15/4.1. | Fax / Post / Email / Self-Service Gateway
Email / Self-Service Gateway |
3.4.3 | Within 1 WD of receipt of 3.4.2 | Acknowledge receipt of Registration of Primary BM Unit request | CRA | Party | As submitted in 3.4.2 | Fax / Email / Self-Service Gateway |
3.4.4 | At the same time as 3.4.3 | Check that the Party is registered with the CRA and that the form or the relevant part of the Self-Service Gateway has been completed by an authorised person. Also check the registration data to confirm the FPN flag has been set correctly. | CRA |
| As submitted in 3.4.2 | Internal Process |
3.4.5 | At the same time as 3.4.3 | Allocate the Additional Primary BM Unit to the Base Trading Unit for the relevant GSP Group (and set the Base Trading Unit Flag for each Primary BM Unit).20, 21 | CRA |
| As submitted in 3.4.2 Creation of new Additional Primary BM Unit for a GSP Group | Internal Process |
3.4.6 | At the same time as 3.4.3 | In all cases inform BSCCo of the Additional Primary BM Unit Registrations. | CRA | BSCCo | Manual request for authorisation | Fax / Email / Self-Service Gateway |
3.4.7 | On receipt of data in 3.4.6 | CRA to receive and register the Working Day Credit Assessment Load Factor (WDCALF), Non-Working Day Credit Assessment Load Factor (NWDCALF), Supplier Export Credit Assessment Load Factor (SECALF), and Transmission Loss Factor (TLF) data for the Primary BM Unit and to ensure that this data is registered prior to the Effective From Date of the Primary BM Unit. | BSCCo | CRA | WDCALF, NWDCALF and SECALF data – Credit Assessment Load Factors (CRA-I011)
Transmission Loss Factors (CRA-I029) | |
3.4.8 | Following 3.4.7 | Confirm all steps in the Primary BM Unit registration process have been completed. | CRA | BSCCo | Completed BSCCo Checklist | Fax / Email / Self-Service Gateway |
3.4.9 | Within 1 WD of 3.4.2 but after 3.4.4 | Inform Party, BSCCo, NETSO and BSC Agents of the Primary BM Unit registration. | CRA | BSCCo NETSO SVAA BSC Agents Party | CRA-I020. BM Unit, Interconnector and GSP Group Data to SVAA (CRA-I015) Registration Report (CRA-I014) to Parties. | Electronic
(Email / Fax to BSC Agents and BSCCo) |
3.4.10 | Following publication of final MDD circular | ‘Point of no return’. In order to ensure full data consistency across all BSC Agent and the NETSO systems a pending Additional Primary BM Unit registration cannot be withdrawn or amended beyond this point except by prior agreement with BSCCo.22 |
|
|
|
|
REF | WHEN | ACTION | FROM | TO | INPUT INFORMATION REQUIRED | MEDIUM |
3.5.1 | At least 25 WD prior to the Effective To Date | Where the circuits associated with the Primary BM Unit are to be disconnected from the Transmission Distribution Systems, request a Certificate of Disconnection. | Party | LDSO23 Or NETSO | Request for Certificate of Disconnection | Fax / Post / Email |
3.5.2 | Within 5 WD of 3.5.1 | Send Certificate of Disconnection. | LDSO
Or NETSO | CRA
Party | Where appropriate a Certificate of Disconnection or BSCP25/5.1 “Deregistration of a TSBP” or BSCP25/5.5 “De-registration of a DSCP”, signed by an authorised person, registered as such using BSCP38. | Fax / Post |
3.5.3 8, 24 | At least 20 WD prior to Effective To Date | Submit de-registration of Primary BM Unit form25 or complete relevant section of the Self-Service Gateway De-registration of Additional Primary BM Units (Supplier only) is processed in parallel with BSCP509 Changes to Market Domain Data26 | Party | CRA | BSCP15/4.2, De-Registration of Primary BM Unit signed by an authorised person, registered as such using BSCP38. | Fax / Post / Email / Self-Service Gateway |
3.5.4 | Upon receipt of 3.5.3 | Check the form or the Self-Service Gateway for completeness and authorisation (as per BSCP38 Authorisations). | CRA |
|
| Internal |
3.5.5 | Within 1 WD of 3.5.4 | Acknowledge receipt of de-registration of Primary BM Unit form | CRA | Party |
| Fax / Post / Email / Self-Service Gateway |
3.5.6 | At the same time as 3.5.5 | Notify CDCA, NETSO and BSCCo of the Primary BM Unit de-registration.27 | CRA | CDCA NETSO BSCCo |
| Fax / Email / Self-Service Gateway |
3.5.7 | At the same time as 3.5.5 | Where the Primary BM Unit is an additional Supplier Primary BM Unit the CRA shall notify the SVAA of the Primary BM Unit.28 | CRA | SVAA29 |
| Email / Fax |
3.5.8 | At the same time as 3.5.5 | Where the Primary BM Unit is embedded within a Distribution System inform the Contracted LDSO of the de-registration. Where the Contracted LDSO is not the Nominated LDSO for the GSP Group, CRA should also inform the Nominated LDSO of the de-registration | CRA | Relevant LDSO(s) | Primary BM Unit information including Effective To Date. | Post / Fax |
3.5.9 | Within 1 WD of 3.5.5 | Where the de-registration is associated with an Interconnector, inform the relevant Interconnector Administrator of the Primary BM Unit de-registration. | CRA | IA | Party Name, Primary BM Unit ID(s) and Effective To Date | Fax / Email |
3.5.10 | At least 15 WD prior to Effective To Date | Confirmation of Effective To Date. | CRA | CDCA NETSO / LDSO Party | Confirmation of Effective To Date | Fax / Email / Self-Service Gateway |
3.5.11 | On or before Effective To Date | Update systems and provide Party, BSCCo, NETSO and BSC Agents with registration reports. | CRA | Party NETSO and BSCCo BSC Agents | Registration reports of data entered onto systems – Registration Report (CRA-I014), Operations Registration Report (CRA – I020), BM Unit, Interconnector and GSP Group Data (CRA-I015). | Electronic |
REF | WHEN | ACTION | FROM | TO | INPUT INFORMATION REQUIRED | MEDIUM |
3.6.1 | As required. | Initiate Market Domain Data (MDD) process (BSCP509) | Party | BSCCo | Form BSCP509/01 & relevant part of entity forms document. Effective To Date must be on or after the MDD Go Live Date. | Fax / Email |
3.6.2 | At least 30 WD prior to Effective To Date | Notification of cessation of a Supplier. Effective To Date must be on or after the MDD Go Live Date. (The requirement for 30WD notice may be reduced if there is agreement between the CRA/BSCCo/Party/NETSO and that this date coincides with a MDD publication date.) | Party | CRA | Letter detailing the cessation of a Supplier with an Effective To Date and a request to de-register the Primary BM Units associated with the Supplier. This letter must state that the Primary BM Units do not have any associated Supplier Volume Allocation (SVA) Metering. | Post / Email / Self-Service Gateway |
3.6.3 | Within 1 WD of receipt of 3.6.2 | Acknowledge receipt of notice of cessation of Supplier. | CRA | Party | Acknowledgement Letter from 3.6.2 | Fax / Email / Self-Service Gateway |
3.6.4 | Following 3.6.3 | De-register all Supplier Primary BM Units for that Supplier. | CRA |
| Supplier Primary BM Units for the Supplier with the Effective To Date. | Internal Process |
3.6.5 | After 3.6.4 | Inform NETSO and BSC Agents of the Primary BM Units de-registration. | CRA | BSCCo NETSO BSC Agents Party | Registration Report (CRA-I014) containing Supplier name, Supplier ID, Effective To Date, Primary BM Unit Ids | Electronic / Email / Fax |
REF | WHEN | ACTION | FROM | TO | INPUT INFORMATION REQUIRED | MEDIUM |
3.7.1 | 10 WD prior to start of next Season | Submit seasonal estimates the maximum and positive magnitude and maximum negative magnitude Primary BM Unit Metered Volume (QMij) for all Primary BM Units. | Party | CRA | BSCP15/4.3, Registration of Seasonal Estimates of the maximum and positive and negative Primary BM Unit Metered Volume | Fax / Post / Self-Service Gateway |
3.7.2 | Within 1 WD of receipt from 3.7.1 | Acknowledge receipt of Registration of seasonal estimates of the maximum and positive magnitude and maximum negative magnitude Primary BM Unit Metered Volume | CRA | Party | As submitted in 3.7.1 | Fax / Post / Email / Self-Service Gateway |
3.7.3 | Before start of new Season | CRA to update their systems with the GC and DC values derived from the estimated maximum positive magnitude and maximum negative magnitude Primary BM Unit Metered Volume. | CRA |
| As submitted 3.7.1 | Internal |
3.7.4 | Within 1 WD of receipt from 3.7.3 | The CRA is to notify, for information only, BSCCo, NETSO, relevant Parties and BSC Agents of the seasonal estimates of the maximum positive magnitude and maximum negative magnitude Primary BM Unit Metered Volume (The NETSO may request the Panel to review a Party’s submission of the maximum and positive magnitude and maximum negative magnitude Primary BM Unit Metered Volume in accordance with Section K of the Code) | CRA | Party NETSO, BSCCo
BSC Agents | Registration Report (CRA-I014) with Seasonal Estimates of the GC/DC for the Primary BM Unit. Operations Registration Report (CRA – I020), Primary BM Unit (CRA – I015). | Email / Fax
Electronic |
REF | WHEN | ACTION | FROM | TO | INPUT INFORMATION REQUIRED | MEDIUM |
3.8.1 | At least 1 WD prior to Effective Date. | Submit revised seasonal estimates of the maximum positive magnitude and maximum negative magnitude Primary BM Unit Metered Volume (QMij) for relevant Primary BM Units. | Party | CRA | BSCP15/4.4, Mid-Season Changes of Maximum Positive and Negative Primary BM Unit Metered Volume Estimates | Email / Fax / Post / Self-Service Gateway |
3.8.2 | Immediately following receipt in 3.8.1 | Acknowledge receipt of changes of seasonal estimates of the maximum positive magnitude and maximum negative magnitude Primary BM Unit Metered Volume. | CRA | Party | As submitted in 3.8.1 | Email / Fax / Self-Service Gateway |
3.8.3 | Within 1 WD of receipt from 3.8.1 | The CRA is to notify BSCCo of the revised seasonal estimates of the maximum positive magnitude and maximum negative magnitude Primary BM Unit Metered Volume. | CRA | BSCCo | As submitted in 3.8.1 Validation by CRA | Email / Fax Electronic |
3.8.4 | Within 1 WD of receipt from 3.8. 1 | If decreasing the magnitude of the DC of a Supplier Primary BM Unit, the CRA will check the number of times the Party has decreased the magnitude of DC for that BSC Season. If Party has reduced magnitude of DC less than twice for that BSC Season, then steps 3.8.5 to 3.8.6 should apply. If DC has already been reduced twice, then steps 3.8.7 to 3.8.8 should apply. | CRA |
| Validation by CRA | Internal Process |
3.8.5 | Within 1 WD of receipt from 3.8.1, if appropriate following 3.8.4 | CRA to update their systems with the revised estimates, to commence from the Effective From Date requested by the Party. | CRA |
| As submitted in 3.8.1 | Internal Process |
3.8.6 | At the same time as 3.8.5 | CRA to notify Party of revised estimates | CRA | Party | Registration Report (CRA-I014) with seasonal estimates for the Primary BM Unit. | Electronic |
3.8.7 | Within 1 WD of receipt from 3.8.1, and following 3.8.4 if the Party has reduced the magnitude of DC more than twice | CRA to update internal records and does not process any GC/DC changes. | CRA |
|
| Email / Fax |
3.8.8 | At same time as 3.8.7 | CRA to notify Party that DC reduction has not been allowed, and the reason why. | CRA | Party |
| Email / Fax |
REF | WHEN | ACTION | FROM | TO | INPUT INFORMATION REQUIRED | MEDIUM |
GC and DC Breach Monitoring | ||||||
3.9.1 | As required. | Monitor Primary BM Unit Metered Volumes from the current BSC Season to identify GC and DC Breaches. | CRA |
| GC and DC Limits | Internal Process |
3.9.2 | Where a GC or DC breach has been identified in 3.9.1. | Send GC or DC Breach Notification, including CRA-Estimated GC or DC Amount. | CRA | Party BSCCo CfD Service Provider CM Service Provider | CRA-I048 ‘GC or DC Breach Notification’ | Email / Self-Service Gateway |
3.9.3 | Where a GC or DC breach has been identified in 3.9.131. | CRA to update the relevant Primary BM Unit’s registration details with the CRA-Estimated GC or DC Amount, to become effective from the next Working Day. | CRA |
| CRA-Estimated GC or DC Amount. | Internal Process |
GC or DC Estimation Challenges by the Lead Party | ||||||
3.9.4 | If required, no later than 2 full WDs of 3.9.2. | Party to raise a GC or DC Estimation Challenge. | Party | CRA and/or BSCCo32 | CRA-I049 ‘GC or DC Breach Estimation Challenge’ | Email / Self-Service Gateway |
3.9.5 | Within 2WDs of 3.9.4. | BSCCo to review evidence submitted by Party and notify Party whether GC or DC Estimation Challenge has been upheld or rejected. | BSCCo | Party | CRA-I049 ‘GC or DC Breach Estimation Challenge’ | Email / Self-Service Gateway |
3.9.6 | Immediately following completion of 3.9.5. | BSCCo to notify CRA of GC or DC Estimation Challenge outcome, including any revised BSCCo-Determined GC or DC Estimates. | BSCCo | CRA | CRA-I050 ‘GC or DC Breach Estimation Challenge Decision’ | Email / Self-Service Gateway |
3.9.7 | Within 1WD of receipt from 3.9.8. | CRA to update the relevant Primary BM Unit registration details with any changes to GC or DC values33, to become effective from the next Working Day34. | CRA |
| CRA-I050 ‘GC or DC Breach Estimation Challenge Decision’ | Internal Process |
REF | WHEN | ACTION | FROM | TO | INPUT INFORMATION REQUIRED | MEDIUM |
3.10.1 | As required. At least 20 WD prior to Requirement Date | Party provides BSCCo with details of the Generating Plant, the reasons for which the Party believes the Generating Plant to be Exemptable, and the P/C Flag that the Lead Party elects for each associated Primary BM Unit should Exemptable status be granted. Or for a Generating Plant whose Exports are measured by SVA Metering Systems, Party provides BSCCo with certification that the Generating Plant is Exemptable and notification of the P/C Flag that the Lead Party elects for each associated Primary BM Unit should Exemptable status be granted. | Party | BSCCo | EITHER Application for Exemptable Generating Plant Status BSCP15/4.5 – (Part A), plus any supporting information where appropriate OR Certification of Exemptable Status for Generating Plant With Exports Measured by SVA Metering Systems BSCP15 / 4.9 – (Part A), plus any supporting information where appropriate | Fax / Post / Email / Self-Service Gateway |
3.10.2 | Upon receipt of 3.10.1 | Determine if further information or other evidence is required to demonstrate compatibility with the Code. | BSCCo |
|
|
|
3.10.3 | If required by BSCCo | Submit further evidence as required. | Party | BSCCo | Details of further information | Fax / Post / Email / Self-Service Gateway |
3.10.4 | Within 20 WD of receipt from 3.10.1 | BSCCo verifies whether or not the Generating Plant is Exemptable and notifies the Party of its conclusion. If the Party agrees with BSCCo’s conclusion, BSCCo updates its records accordingly. If the Party does not agree, go to step 3.10.7. | BSCCo | Party | EITHER Application for Exemptable Generating Plant Status BSCP15/4.5 – (Part B) OR Certification of Exemptable Status for Generating Plant With Exports Measured by SVA Metering Systems BSCP15/4.9 – (Part B) | Fax / Post / Email / Self-Service Gateway |
3.10.5 | At the same time as 3.10.4 | Where the Generating Plant is granted Exemptable status, BSCCo will notify CRA to set the Exempt Export Flag and P/C Flag for each Primary BM Unit that comprises the Exemptable Generating Plant. | BSCCo | CRA | BSCP15/4.7 Commencement / Termination of Exempt Export Primary BM Unit Status | Fax / Post / Email / Self-Service Gateway |
3.10.6 | Within 1 WD of 3.10.5 | Set the Exempt Export Flag and P/C Flag for each Primary BM Unit that comprises the Exemptable Generating Plant. If the Exempt Export Primary BM Unit is Embedded, and unless notified otherwise by the Lead Party in accordance with BSCP31, allocate the Exempt Export Primary BM Unit to the Base Trading Unit for its GSP Group and set the Base Trading Unit Flag for the Primary BM Unit.35 If the Exempt Export Primary BM Unit is Directly Connected, and unless notified otherwise by the Lead Party in accordance with BSCP31, allocate the Exempt Export Primary BM Unit to a Sole Trading Unit.35 Notify the Lead Party, BSCCo and the NETSO. | CRA | Lead Party BSCCo NETSO BSC Agents | Registration Report CRA – I014 Operations Registration Report CRA – I020 BM Unit, Interconnector and GSP Group Data CRA – I015 | Electronic, or equivalent |
3.10.7 | Upon receipt of 3.10.4 and if the Party disagrees with the decision | BSCCo refers application to the Panel on behalf of Party. | BSCCo | Panel | As submitted in 3.10.1 and, if appropriate 3.10.3. | Post / Email |
3.10.8 | Upon receipt of 3.10.7 | Panel determines whether (in its opinion) Generating Plant is Exemptable and notifies BSCCo of its decision. | Panel | BSCCo | Details of decision | Panel Meeting |
3.10.9 | Within 1 WD of Panel Meeting | BSCCo notifies Party of Panel’s decision. If the Party agrees with the decision, BSCCo updates its records accordingly. If the Party does not agree with the decision, go to step 3.10.12. | BSCCo | Party | Details of decision | Fax / Post / Email |
3.10.10 | At the same time as 3.10.9 | Where the Generating Plant is granted Exemptable status, BSCCo will notify CRA to set the Exempt Export Flag and P/C Flag for each Primary BM Unit that comprises the Exemptable Generating Plant. | BSCCo | CRA | BSCP15/4.7 Commencement / Termination of Exempt Export Primary BM Unit Status | Fax / Post / Email / Self-Service Gateway |
3.10.11 | Within 1 WD of 3.10.10 | Set the Exempt Export Flag and P/C Flag for each Primary BM Unit that comprises the Exemptable Generating Plant. If the Exempt Export Primary BM Unit is Embedded, and unless notified otherwise by the Lead Party in accordance with BSCP31, allocate the Exempt Export Primary BM Unit to the Base Trading Unit for its GSP Group and set the Base Trading Unit Flag for the Primary BM Unit.35 If the Exempt Export Primary BM Unit is Directly Connected, and unless notified otherwise by the Lead Party in accordance with BSCP31, allocate the Exempt Export Primary BM Unit to a Sole Trading Unit.35 Notify the Lead Party, BSCCo and the NETSO. | CRA | Lead Party BSCCo NETSO BSC Agents | Registration Report CRA – I014 Operations Registration Report CRA – I020 BM Unit, Interconnector and GSP Group Data CRA – I015 | Electronic, or equivalent |
3.10.12 | Within 20 WD of receipt from 3.10.9 and if the Party disagrees with the decision | Party refers application to the Authority. | Party | Authority | As submitted in 3.10.1 and, if appropriate 3.10.3. | Fax / Post / Email |
3.10.13 | Upon receipt of 3.10.12 | Authority determines whether Generating Plant is Exemptable and notifies Party and BSCCo of its decision. If the Party agrees with the decision, BSCCo updates its records accordingly. | Authority | Party BSCCo | Details of decision. | Fax / Post / Email |
3.10.14 | At the same time as 3.10.13 | Where the Generating Plant is granted Exemptable status, BSCCo will notify CRA to set the Exempt Export Flag and P/C Flag for each Primary BM Unit that comprises the Exemptable Generating Plant. | BSCCo | CRA | BSCP15/4.7 Commencement / Termination of Exempt Export Primary BM Unit Status | Fax / Post / Email / Self-Service Gateway |
3.10.15 | Within 1 WD of 3.10.14 | Set the Exempt Export Flag and P/C Flag for each Primary BM Unit that comprises the Exemptable Generating Plant. If the Exempt Export Primary BM Unit is Embedded, and unless notified otherwise by the Lead Party in accordance with BSCP31, allocate the Exempt Export Primary BM Unit to the Base Trading Unit for its GSP Group and set the Base Trading Unit Flag for the Primary BM Unit.35 If the Exempt Export Primary BM Unit is Directly Connected, and unless notified otherwise by the Lead Party in accordance with BSCP31, allocate the Exempt Export Primary BM Unit to a Sole Trading Unit.35 Notify the Lead Party, BSCCo and the NETSO. | CRA | Lead Party BSCCo NETSO BSC Agents | Registration Report CRA – I014 Operations Registration Report CRA – I020 BM Unit, Interconnector and GSP Group Data CRA – I015 | Electronic, or equivalent |
REF | WHEN | ACTION | FROM | TO | INPUT INFORMATION REQUIRED | MEDIUM |
3.11.1 | As required | Where the Exempt Export Status is to be terminated, provide CRA with completed form BSCP15/4.7 or relevant part of the Self-Service Gateway, requesting and authorising CRA to unset the Exempt Export Flag and P/C Flag for the Primary BM Unit. Notify the Party of the termination. | BSCCo | CRA Lead Party | Form BSCP15/4.7 Commencement / Termination of Exempt Export Primary BM Unit Status. | Fax / Post / Email / Self-Service Gateway |
3.11.2 | Within 1 WD of 3.11.1 | Unset the Exempt Export Flag and the P/C Flag for the Primary BM Unit.36 If a CVA Primary BM Unit, ensure that the Primary BM Unit is allocated to a Sole Trading Unit.37 If a Supplier (Base or Additional) Primary BM Unit, ensure that the Primary BM Unit is allocated to the Base Trading Unit for its GSP Group.37 Notify the Lead Party, BSCCo and the NETSO. | CRA | Lead Party BSCCo NETSO BSC Agents | Registration Report CRA – I014 Operations Registration Report CRA – I020 BM Unit, Interconnector and GSP Group Data CRA – I015 | Electronic or equivalent |
REF | WHEN | ACTION | FROM | TO | INPUT INFORMATION REQUIRED | MEDIUM |
3.12.1 | From time to time if the Lead Party requires | Submit notice to the CRA, copied to BSCCo, requesting a change to the Production / Consumption Flag for an Exempt Export Primary BM Unit. The request should contain an effective date for such amendment of at least 2 WD from this notice unless otherwise agreed with the CRA/BSCCo. | Lead Party | CRA BSCCo | Form BSCP15/4.8 Election of Production / Consumption Flag for Exempt Export Primary BM Unit or Secondary BM Unit or Self-Service Gateway equivalent | Fax / Post / Email or Self-Service Gateway equivalent |
3.12.2 | Within 1 WD of receipt of 3.12.1 | CRA ensures that the Exempt Export Flag is set for the Primary BM Unit. This may involve obtaining authorisation from BSCCo. | CRA |
| As submitted in 3.12.1 | Internal |
3.12.3 | As soon as practicable after 3.12.2. | Where the Exempt Export Flag is set, then amend the P/C Flag for the Primary BM Unit, effective from the specified date (or 2 WD from 3.12.1, if the specified date is less than 2 WD and no reduced timescale has been agreed). Notify the Party of the change to P/C Flag. | CRA | Party | Registration Report CRA – I014 | Electronic |
3.12.4 | As soon as practicable after 3.12.2. | Notify BSCCo and BSC Agents of the change to P/C Flag. | CRA | BSCCo BSC Agents | CRA – I020 to BSCCo CRA – I015 to BSC Agents | Fax / Email / Electronic |
3.12.5 | As soon as practicable after 3.12.2. | Where the Exempt Export Flag is not set, then do not amend the P/C Flag for the Primary BM Unit. Notify the Party of the rejection of the request. | CRA | Party |
Form BSCP15/4.8 Specifying reason for rejection. | Fax / Post / Email or Self-Service Gateway equivalent |
REF | WHEN | ACTION | FROM | TO | INPUT INFORMATION REQUIRED | MEDIUM |
3.13.1 | If required and at least 3 WD prior to 3.13.3 | Request details of current registrations of Primary BM Unit(s), any associated MSID(s) including any metering dispensations associated with the MSID(s), and of Trading Unit(s). | Party registering Primary BM Unit(s) Party de-registering Primary BM Unit(s) | CRA | Letter detailing the information required from BSCCo including the site name and if available the Primary BM Unit Id(s). The letter should be signed by a Category ‘A’ or ‘F’ authorised signatory.38 | Fax / Post / Email / Self-Service Gateway |
3.13.2 | Within 2 WD of receipt of request in 3.13.1 | Send information requested in 3.13.1. | CRA | Party registering Primary BM Unit(s) Party de-registering Primary BM Unit(s) | Information requested in 3.13.1.
| Fax / Post / Email / Self-Service Gateway |
3.13.3 | As required and at least 5 WD prior to date of transfer | Submit BSCP15/4.11 Part A to de-register Primary BM Unit(s) Please note that if the last Primary BM Unit(s) associated with a particular Party role are being de-registered then the Party is advised to also complete a BSCP65/01 form in order to de-register that role. | Party de-registering Primary BM Unit(s) | CRA | BSCP15/4.11 Part A39 | Fax / Post / Email / Self-Service Gateway |
3.13.4 | As required and at least 5 WD prior to date of transfer | Submit BSCP15/4.11 Part B to register Primary BM Unit(s). Please note that if any new Primary BM Unit(s) result in a new Party role being required, the Party is advised to complete a BSCP65/01 form to register that new role and follow BSCP70 to ensure all required qualification tests for the new role have been passed. If Primary BM Unit is already an Exempt Export Primary BM Unit, elect the P/C Flag to apply to the Primary BM Unit from the CoPBLP Effective From Date. | Party registering Primary BM Unit(s) | CRA | BSCP15/4.11 Part B | Fax / Post / Email / Self-Service Gateway |
3.13.5 | At the same time as 3.13.3 and 3.13.4 | For Primary BM Units which are part of an existing Trading Unit (other than a Sole or Base Trading Unit) all Lead Parties within the Trading Unit should be informed of the CoPBLP, and should confirm their agreement to the CoPBLP in writing. | CRA Trading Unit Lead Parties | Trading Unit Lead Parties CRA | Details of CoPBLP Confirmation of agreement to the CoPBLP | Fax / Post / Email |
3.13.6 | On receipt of both 3.13.3 and 3.13.4 | Validate BSCP15 /4.11 Parts A and B or the relevant information within the Self-Service Gateway. If validation checks are passed, go to 3.13.7 If validation checks are failed, go to 3.13.9 | CRA |
| Confirmation that the Party registering the Primary BM Units has acceded, qualified and registered in the appropriate role. Confirmation that the dates specified on both the BSCP15 /4.11 forms Parts A and B or within the Self-Service Gateway are consecutive. | Internal Process |
3.13.7 | Within 1 WD of receipt of both 3.13.3 and 3.13.4 | Send copies of BSCP15 /4.11 Parts A and B to the NETSO. Request that the NETSO confirm that they have no objections to the CoPBLP. | CRA | NETSO |
| Fax / Email |
3.13.8 | Within 2 WD of receipt of 3.13.7 | Send written confirmation that the NETSO has no objections to the CoPBLP or state that the NETSO has an objection to the CoPBLP and the reasons for this objection. If the NETSO has any objections, go to 3.13.9 If the NETSO has no objections, go to 3.13.10 | NETSO | CRA | Confirmation of no objections or objection specified. | Fax / Post / Email |
3.13.9 | Within 1 WD of 3.13.6 or 3.13.8 | In the case that the validation checks are failed and/or the NETSO has an objection, inform both Parties of the rejection and the reason for the rejection. | CRA | Party de-registering Primary BM Unit(s) Party registering Primary BM Unit(s) | Notification of rejection and reasons for the rejection. | Fax / Post / Email / Self-Service Gateway |
3.13.10 | Within 1 WD of the Effective From Date | Process CoPBLP in systems. | CRA NETSO (where appropriate) |
| BSCP 15/4.11 Parts A and B | Internal Process |
3.13.11 | At the same time as 3.13.10 if the Primary BM Unit is an Exempt Export Primary BM Unit | Set P/C Flag for the Primary BM Unit as elected by the Party in 3.13.4. | CRA |
| BSCP 15/4.11 Part B | Internal Process / Self-Service Gateway |
3.13.12 | At the same time as 3.13.10 if the Primary BM Unit is Embedded | Inform the Nominated LDSO of the CoPBLP. | CRA | Nominated LDSO | Party IDs of the Lead Parties registering and de-registering the Primary BM Unit(s), Primary BM Unit Id(s) and the Effective From Date. | Fax / Email |
3.13.13 | Within 1 WD of 3.13.12 | Inform NETSO, BSCCo, BSC Agents, Party de-registering the Primary BM Unit(s) and Party registering the Primary BM Unit(s). | CRA | BSCCo NETSO BSC Agents Party de-registering Primary BM Unit(s) Party registering Primary BM Unit(s) | Operations Registration Report to BSCCo & NETSO (CRA-I020)
Registration Report to Parties (CRA-I014) Primary BM Unit, Interconnector and GSP Group Data to BSC Agents (CRA – I015) | Electronic Email confirmation to BSCCo |
3.13.14 | Within 1 WD of 3.13.12 | Submit Meter Technical details to Party registering the Primary BM Unit(s). | CDCA | Party registering Primary BM Unit(s) | Meter Technical Details (CDCA-I051) | Fax / Email |
REF | WHEN | ACTION | FROM | TO | INPUT INFORMATION REQUIRED | MEDIUM |
3.14.1 | As required | Submit Notification of Supplier ID Transfer. If the Supplier ID being transferred is the last of the Transferor’s Supplier IDs then the Party must also complete a BSCP 65 4.1 form or the relevant section of the Self-Service Gateway in order to de-register the Supplier role. | Supplier ID Transferor | CRA | Notification of a Supplier ID Transfer (BSCP 15/4.6 – Part A) or the relevant section of the Self-Service Gateway | Fax / Post / Email / Self-Service Gateway |
3.14.2 | At the same time as 3.14.1 | Submit Notification of Supplier ID Transfer | Supplier ID Transferee | CRA | Notification of a Supplier ID Transfer (BSCP 15/ 4.6 – Part B) or the relevant section of the Self-Service Gateway | Fax / Post / Email / Self-Service Gateway |
3.14.3 | On receipt of both 3.14.1 and 3.14.2 | Validate the documentation. | CRA |
| Ensure that the Transferee has Acceded and qualified in the role of Supplier. Ensure that the Supplier IDs, Party Ids and dates specified on both the BSCP 15 /4.6 forms (A) and (B) or the relevant section of the Self-Service Gateway, match. | Internal Process |
3.14.4 | Within 1 WD of 3.14.3. | In the case that the validation checks are failed, inform both the Supplier ID Transferor and the Supplier ID Transferee of the rejection and the reason for the rejection. | CRA | Supplier ID Transferor Supplier ID Transferee | Notification of Supplier ID Transfer rejection and reasons for the rejection. | Fax / Post / Email / Self-Service Gateway |
3.14.5 | At the same time as 3.14.3 | In the case that the validation checks are passed, identify the Primary BM Units (both Base and Additional, including any Exempt Export Primary BM Units) associated with the relevant Supplier ID. | CRA |
| Internal process. |
|
3.14.6 | Immediately following 3.14.5 | Notify the Transferee of the P/C Status of any Exempt Export Primary `BM Unit(s) associated with the relevant Supplier ID.40 | CRA | Supplier ID Transferee | Details of the P/C Status of any Exempt Export Primary BM Unit(s) associated with the relevant Supplier ID. | Fax / Email / Self-Service Gateway |
3.14.7 | Within 1 WD of 3.14.6 or as required to meet the Effective From date | Request that the NETSO identifies the Primary BM Units (both Base and Additional, including any Exempt Export Primary BM Units) associated with the relevant Supplier ID and transfers them from the Transferor to the Transferee. | CRA | NETSO | Copies of BSCP15 4.6 (A) and 4.6 (B) forms and authorisation to identify the associated Primary BM Units and transfer them from the Supplier ID Transferor to the Supplier ID Transferee. | Fax / Email |
3.14.8 | At the same time as 3.14.7 | Notify the Authority and each Party. | BSCCo | Authority All Parties | ELEXON Circular41 | Fax / Post / Email |
3.14.9 | Within 1 WD of 3.14.7 or as required to meet the Effective From date | Transfer the Primary BM Units identified in 3.14.5 from the Transferor to the Transferee. | CRA NETSO (where appropriate) |
| Internal Process | Internal Process |
3.14.10 | Within 1 WD of 3.14.7 | Inform the NETSO, BSCCo, BSC Agents and the Parties involved of the Transfer. | CRA | BSCCo NETSO SVAA BSC Agents Supplier ID Transferor Supplier ID Transferee | Operations Registration Report to BSCCo & NETSO (CRA-I020)
BM Unit and GSP Group Registration Data to SVAA & BSC Agents (CRA-I015)
Registration Report to Parties (CRA-I014) | Electronic
Email to BSCCo |
REF | WHEN | ACTION | FROM | TO | INPUT INFORMATION REQUIRED | METHOD |
3.15.1 | As determined by Party | Submit form BSCP15/4.10 Part A or complete the relevant section on the Self-Service Gateway | BSC Party | BSCCo | BSCP15/4.10 Part A Application or the relevant section of the Self-Service Gateway, for inclusion in BSC Website list of Suppliers which have satisfied the criteria to complete a change of Primary BM Unit Lead Party within 5 WD for a Primary BM Unit with CVA metering and associated with a Customer premises. | Post/Fax/Email / Self-Service Gateway |
3.15.2 | Within 1 WD of receipt of BSCP15/4.10 Part A or submission by Party the required information on the relevant section of the Self-Service Gateway | Request that the NETSO confirm whether or not the Party has appropriate registration on the NETSO’s systems and has use of a qualified Trading Agent and Trading Point in order to complete a change of Primary BM Unit Lead Party within 5 WD. | BSCCo | NETSO | Party ID and request for confirmation as to whether the Party is appropriately registered on the NETSO’s systems and has use of a qualified Trading Agent and Trading Point. | Fax/Email |
3.15.3 | At the same time as 3.15.2 | Check whether the Party has: Acceded to the BSC and completed Party registration in the role of Supplier; and Successfully completed registration and trading flows to register as a Supplier and completed metering flows to register CVA Primary BM Units. | BSCCo |
| Party ID | Internal Process |
3.15.4 | Within 2 WD of receipt of request in 3.15.2 | Confirm whether the Party is appropriately registered on the NETSO’s systems and has use of a qualified Trading Agent and Trading Point in order to complete a change of Primary BM Unit Lead Party within 5 WD. | NETSO | BSCCo | Confirmation whether the Party is appropriately registered on the NETSO’s systems and has use of a qualified Trading Agent and Trading Point. | Fax/Email |
3.15.5 | Within 2 WD of 3.15.4 | Send a completed BSCP15/4.10 Part B form or the online equivalent of the form to the Party to notify them of the outcome of their application. | BSCCo | Party | BSCP15/4.10 Part B, Application for inclusion in BSC Website list of Suppliers or the online equivalent of the form which have satisfied the criteria to complete a change of Primary BM Unit Lead Party within 5 WD for a Primary BM Unit with CVA metering and associated with a Customer premises. | Post/ Fax/ Email / Self-Service Gateway |
3.15.6 | At the same time as 3.15.5 | Where the Party has met the criteria checked by the NETSO in 3.14.2 and by BSCCo in 3.14.3, add the Party Name and ID to the BSC Website list of Suppliers which have satisfied the criteria to complete a change of Primary BM Unit Lead Party within 5 WD for a Primary BM Unit with CVA metering and associated with a Customer premises. | BSCCo |
| Party Name and ID. | Internal Process |
REF | WHEN | ACTION | FROM | TO | INPUT INFORMATION REQUIRED | MEDIUM |
3.18.1 | As required | Notify need for Additional Primary BM Unit registration | Supplier | BSCCo | BSCP15/4.1, Registration of Primary BM Unit or its online equivalent signed by an authorised person, registered as such using BSCP38 and including name, address and CFD ID provided by the generator with a CFD. BMU Id and BMU Name must follow naming convention on BSC website. | Email / Self-Service Gateway |
3.18.2 | Within 1 WD of 3.18.1 | Confirm registration is required for CFD | BSCCo | CFDSSP | As submitted in 3.18.1 | Email / Self-Service Gateway |
3.18.3 | Within 1 WD of 3.18.2 or as required | Instruct registration details | CFDSSP | BSCCo | Registration details, including CFD ID, GSP Group, and whether to register based on specific Supplier ID(s) or the list maintained in procedure 3.20 | Email / Self-Service Gateway |
3.18.4 | Within 1 WD of 3.18.3 | Acknowledge and validate request, including Effective From Dates of request and MDD timetable (Effective From Date must be on or after the MDD Go Live Date and registration request must be at least 15 WD18 prior to Effective From Date.) | BSCCo | CFDSSP | As submitted in 3.18.3 | Email / Self-Service Gateway |
3.18.5 | Following 3.18.4 | Initiate Market Domain Data process (BSCP509) | BSCCo |
| Form BSCP509/01 & relevant entity forms. | Internal Process |
|
| Initiate Registration of Primary BM Units based on registration details | BSCCo | CRA | BSCP15/4.1 or its online equivalent | Email / Self-Service Gateway |
13.18.6 | Within 1 WD of receipt of 3.18.5 | Acknowledge receipt of Registration request | CRA | BSCCo | As submitted in 3.18.5 |
|
3.18.7 | At the same time as 13.18.6 | Check that the Party is registered with the CRA and that the form or its online equivalent has been completed by an authorised person. Also check the registration data to confirm the FPN flag has been set correctly. | CRA |
| As submitted in 3.18.5 | Internal Process |
3.18.8 | As the same time as 3.18.6 | Where FPN flag is set to ‘Y’, inform the NETSO of the intended Primary BM Unit registration. | CRA | NETSO |
| |
3.18.9 | Within 5WD of 3.18.8 | The NETSO may object to the registration. | NETSO | CRA | A statement detailing the nature of the objection Where an objection cannot be resolved, the CRA shall escalate the objection to BSCCo | |
3.18.10 | Following 3.18.9 | Allocate the Additional Primary BM Unit(s) to the Base Trading Unit for the relevant GSP Group (and set the Base Trading Unit Flag for each Primary BM Unit). | CRA |
| As submitted in 3.18.5 Creation of new Additional Primary BM Unit for a GSP Group | Internal Process |
3.18.11 | On receipt of data in 3.18.6 | CRA to receive and register the Working Day Credit Assessment Load Factor (WDCALF), Non-Working Day Credit Assessment Load Factor (NWDCALF), Supplier Export Credit Assessment Load Factor (SECALF), and Transmission Loss Factor (TLF) data for the Primary BM Unit and to ensure that this data is registered prior to the Effective From Date of the Primary BM Unit. | BSCCo | CRA | WDCALF, NWDCALF and SECALF data – Credit Assessment Load Factors (CRA-I011)
Transmission Loss Factors (CRA-I029) | Email / Self-Service Gateway |
3.18.12 | Following 3.18.11 | Confirm all steps in the Primary BM Unit registration process have been completed. | CRA | BSCCo | Completed BSCCo Checklist | Email / Self-Service Gateway |
3.18.13 | Within 1 WD of 3.18.5 but after 3.18.7 | Inform Party, BSCCo, NETSO and BSC Agents of the Primary BM Unit registration. | CRA | BSCCo NETSO SVAA BSC Agents Lead Party | CRA-I020. BM Unit, Interconnector and GSP Group Data to SVAA (CRA-I015) Registration Report (CRA-I014) to Parties. | Electronic (Email to BSC Agents and BSCCo) |
3.18.14 | Following publication of final MDD circular42 | ‘Point of no return’. In order to ensure full data consistency across all BSC Agent and the NETSO systems a pending Additional Primary BM Unit registration cannot be withdrawn or amended beyond this point except by prior agreement with BSCCo |
|
|
|
|
REF | WHEN | ACTION | FROM | TO | INPUT INFORMATION REQUIRED | MEDIUM |
3.19.1 | As required43 | Instruct de-registration details | CFDSSP | BSCCo | De-registration details, including CFD ID, GSP Group, and whether to deregister based on specific Supplier ID(s) or list maintained in 3.20 |
|
3.19.2 | Following 3.19.1 | Acknowledge and validate request, including Effective To Dates of request and MDD timetable (Effective To Date must be on or after the MDD Go Live Date and registration request must be at least 20 WD prior to Effective To Date.) | BSCCo | CFDSSP | As submitted in 3.19.1 |
|
3.19.3 | At least 20 WD prior to Effective To Date | Initiate Market Domain Data process (BSCP509) 44 | BSCCo |
| Based on list maintained under 3.20 and details provided in 3.19.1 | Internal Process |
|
| Submit de-registration of Primary BM Unit form or its equivalent on the Self-Service Gateway | BSCCo | CRA | BSCP15/4.2, De-Registration of Primary BM Unit or its online equivalent | Email / Self-Service Gateway |
3.19.4 | Upon receipt of 3.19.3 | Check the form or its Self-Service Gateway equivalent for completeness and authorisation | CRA |
|
| Internal |
3.19.5 | Within 1 WD of 3.19.4 | Acknowledge de-registration request. Where FPN set to ‘yes’, notify the NETSO45. | CRA | BSCCo NETSO |
| Email / Self-Service Gateway |
3.19.6 | At the same time as 3.19.4 | Notify the SVAA of the Primary BM Unit.46 | CRA | SVAA47 |
| Email / Self-Service Gateway |
3.19.7 | At least 15 WD prior to Effective To Date | Confirmation of Effective To Date. | CRA | NETSO / Party | Confirmation of Effective To Date | Email / Self-Service Gateway |
3.19.8 | On or before Effective To Date | Update systems and provide Party, BSCCo, NETSO and BSC Agents with registration reports. | CRA | Party | Registration reports of data entered onto systems – Registration Report (CRA-I014), | Electronic |
|
|
|
| NETSO and BSCCo | Operations Registration Report (CRA – I020), |
|
|
|
|
| BSC Agents | BM Unit, Interconnector and GSP Group Data (CRA-I015). |
|
REF | WHEN | ACTION | FROM | TO | INPUT INFORMATION REQUIRED | MEDIUM |
3.20.1 | As required | Request inclusion/exclusion from list | Supplier / CFDSSP | BSCCo | Supplier ID, GSP Group and details of request | |
3.20.2 | Within 5 WD of 3.20.1 and before 3.20.3 | Validate and acknowledge request. Where request from Supplier check for authorisation (as per BSCP38) | BSCCo | Supplier / CFDSSP | As submitted in 13. 20.1 | |
3.20.3 | Following 3.20.2 and at least quarterly | Update list | BSCCo |
| As submitted in 13.20.1 and based on those active Half Hourly Export Suppliers within each GSP Group | Internal Process |
REF | WHEN | ACTION | FROM | TO | INPUT INFORMATION REQUIRED | MEDIUM |
3.21.1 | At least 15 WD prior to Effective From Date | Submit Registration of Secondary BM Unit form | Virtual Lead Party or Asset Metering Virtual Lead Party | CRA | BSCP15/4.14, Registration of Secondary BM Unit signed by an authorised person, registered as such using BSCP38.
Where a party wishes for a Settlement Expected Volume (SEV) to replace the FPN they will indicate that the BM Unit is a Baselined BM Unit in form BSCP15/4.14. | Email/ Self-Service Gateway |
3.21.2 | Within 1 WD of receipt of 3.21.1 | Acknowledge receipt of Registration of Secondary BM Unit form | CRA | Virtual Lead Party or Asset Metering Virtual Lead Party | As submitted in 3.21.1 | Email/Self-Service Gateway |
3.21.3 | At the same time as 3.21.2 | CRA checks the following:
| CRA |
| As submitted in 3.21.1 | Internal Process |
3.21.4 | At the same time as 3.21.2 | In all cases inform BSCCo of the Secondary BM Unit Registration. | CRA | BSCCo |
| Email/Self-Service Gateway |
3.21.5 | On receipt of data in 3.21.4 | BSCCo to send data to CRA. CRA to register the Transmission Loss Factor (TLF) data for the Secondary BM Unit and ensure that this data is registered prior to the Effective From Date of the Secondary BM Unit. | BSCCo | CRA | Transmission Loss Factors (CRA-I029) | Email/Self-Service Gateway |
3.21.6 | On or before Effective From Date | Inform Virtual Lead Party or Asset Metering Virtual Lead Party, BSCCo, NETSO and BSC Agents of the Secondary BM Unit registration. | CRA | Virtual Lead Party or Asset Metering Virtual Lead Party BSCCo NETSO BSC Agents | CRA-I020. BM Unit, Interconnector and GSP Group Data to SVAA (CRA-I015) Registration Report (CRA-I014) to Parties. | Email/Self-Service Gateway |
REF | WHEN | ACTION | FROM | TO | INPUT INFORMATION REQUIRED | MEDIUM |
3.22.1 | At least 20 WD prior to Effective To Date | Submit de-registration of Secondary BM Unit form48. | Virtual Lead Party or Asset Metering Virtual Lead Party | CRA | BSCP15/4.15, De-Registration of Secondary BM Unit signed by an authorised person, registered as such using BSCP38. | Email/Self-Service Gateway |
3.22.2 | Upon receipt of 3.5.3 | Check the form for completeness and authorisation (as per BSCP38 Authorisations). | CRA |
|
| Internal |
3.22.3 | Within 1 WD of 3.5.4 | Acknowledge receipt of de-registration of Secondary BM Unit form | CRA | Virtual Lead Party or Asset Metering Virtual Lead Party |
| Email/Self-Service Gateway |
3.22.4 | At the same time as 3.5.5 | Notify NETSO and BSCCo of the Secondary BM Unit de-registration49. | CRA | NETSO BSCCo |
| Email/Self-Service Gateway |
3.22.5 | At least 15 WD prior to Effective To Date | Confirmation of Effective To Date. | CRA | NETSO / LDSO Virtual Lead Party or Asset Metering Virtual Lead Party | Confirmation of Effective To Date | Email/Self-Service Gateway |
3.22.6 | On or before Effective To Date | Update systems and provide Party, BSCCo, NETSO and BSC Agents with registration reports. | CRA | Virtual Lead Party or Asset Metering Virtual Lead Party NETSO and BSCCo BSC Agents | Registration reports of data entered onto systems – Registration Report (CRA-I014), Operations Registration Report (CRA – I020), BM Unit, Interconnector and GSP Group Data (CRA-I015). | Email/Self-Service Gateway |
REF | WHEN | ACTION | FROM | TO | INPUT INFORMATION REQUIRED | MEDIUM |
3.23.1 | From time to time if the Virtual Lead Party or Asset Metering Virtual Lead Party requires | Submit notice to the CRA, copied to BSCCo, requesting a change to the Production / Consumption Flag for a Secondary BM Unit. The request should contain an effective date for such amendment of at least 2 WD from this notice unless otherwise agreed with the CRA/BSCCo. | Virtual Lead Party or Asset Metering Virtual Lead Party | CRA BSCCo | Form BSCP15/4.8 Election of Production / Consumption Flag for Exempt Export Primary BM Unit or Secondary BM Unit | Email/Self-Service Gateway |
3.23.2 | As soon as practicable after 3.23.1. | Amend the P/C Flag for the Secondary BM Unit, effective from the specified date (or 2 WD from 3.23.1, if the specified date is less than 2 WD and no reduced timescale has been agreed). Notify the Virtual Lead Party or Asset Metering Virtual Lead Party of the change to P/C Flag. | CRA | Virtual Lead Party or Asset Metering Virtual Lead Party | Registration Report CRA – I014 | Email/Self-Service Gateway |
3.23.3 | At the same time as 3.23.2 | Notify BSCCo and BSC Agents of the change to P/C Flag. | CRA | BSCCo BSC Agents | CRA – I020 to BSCCo CRA – I015 to BSC Agents | Email/Self-Service Gateway |
REF | WHEN | ACTION | FROM | TO | INPUT INFORMATION REQUIRED | MEDIUM |
3.24.1 | At least 30 WD prior to Effective From Date of the reconfiguration | Submit Registration of BM Unit form and an electrical single line diagram(s) showing the location of the Metering Equipment, in particular the Settlement current and voltage transformers (CTs/VTs) and CT/VT ratios, and all existing Boundary Points and any System Connection Points at or near the proposed Boundary Point(s).50 51 | Party | CRA | BSCP15/4.1, Registration of BM Unit signed by an authorised person, registered as such using BSCP38. | Fax / Post / Email |
3.24.2 | Within 1 WD of receipt of 3.24.1 | Acknowledge receipt of Registration of BM Unit form | CRA | Party |
| Fax / Email / Post |
3.24.3 | At the same time as 3.24.2 | The CRA checks the following:
| CRA |
| As submitted in 3.24.1 | Internal Process |
3.24.4 | At the same time as 3.24.2 | Inform CDCA, NETSO and BSCCo of the intended BM Unit registration. | CRA | CDCA NETSO BSCCo |
| Fax / Email |
3.24.5 | Within 5 WD of 3.24.4 | Where the Party is applying to register 2 or more Offshore Power Park Modules as a Combined Offshore BM Unit, the NETSO shall confirm whether it determines that such a configuration is suitable to constitute a single BM Unit. | NETSO | CRA BSCCo | A statement as to whether the NETSO determines that the Party’s requested configuration of Offshore Power Park Modules is suitable to constitute a single BM Unit | Fax / Email / Post |
3.24.6 | Within 5 WD of 3.24.4 and (if applicable) at the same time as 3.22.5 | The NETSO may object to the registration. | NETSO | CRA | A statement detailing the nature of the objection Where an objection cannot be resolved, the CRA shall escalate the objection to BSCCo | Fax / Email / Post |
3.24.7 | 15 WD prior to the Effective From Date and if required | BSCCo to send data to CRA. CRA to register the Working Day Credit Assessment Load Factor (WDCALF), Non-Working Day Credit Assessment Load Factor (NWDCALF) and Supplier Export Credit Assessment Load Factor (SECALF) data for the BM Unit and ensure that this data is registered prior to the Effective From Date of the BM Unit. | BSCCo | CRA | WDCALF, NWDCALF and SECALF data – Credit Assessment Load Factors (CRA-I011) Transmission Loss Factors (CRA-I029) | |
3.24.8 | 5 WD prior to Effective From Date | CDCA to confirm the following:
| CDCA | CRA | Metering System proving test results, Meter Aggregation Rules | Email / Fax / Electronic |
3.24.9 | If applicable on or before Effective From Date | Provide Party and BSC Agents with registration reports52. | CRA | Party
NETSO and BSCCo BSC Agents | Registration reports of data entered onto systems including Effective From Date – Registration Report (CRA-I014), Operations Registration Report (CRA – I020), BM Unit, Interconnector and GSP Group Data (CRA-I015). | Electronic |
To: CRA | Date Sent: |
From: Participant Details | |
Party ID: | Name of Sender: |
Contact email address: | |
Our Ref: | Contact Tel. No. |
Name of Authorised Signatory: | |
Authorised Signature: | Password: |
Is this Primary BM Unit registration: | |
[ ] | a New Primary BM Unit Registration |
[ ] | a re-configuration of existing plant and apparatus |
[ ] | a Change of registration data associated with a Change of Primary BM Unit Lead Party |
[ ] | subject to a Registration Transfer in accordance with BSCP68 |
[ ] | a change in status of a Primary BM Unit’s FPN Flag |
[ ] | Baselined BM Unit Indicator (delete as applicable)54 |
[ ] | a change in the Switching Group to which the BM Unit belongs |
[ ] | an Additional Primary BM Unit registration for CFD Assets |
[ ] | an Additional Primary BM Unit registration under instruction of the CFDSSP (only BSCCo should tick this box) |
(Tick as appropriate) |
Primary BM Unit Id | Primary BM Unit Name(Max 30 Characters) | NGC BM Unit ID55 | BM Unit Type56 | Primary BM Unit Configuration57 | GSP Group Id 58 | GC (MW) | DC (MW) | Interconnector Primary BM Unit P/ C Flag 59 | FPN Flag (Y/N) | Exempt Export (optional)60 | Inter-connector Id 61 | Baselined BM Unit Y/N 62 | EFD |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
If BM Unit Configuration is ‘Meets criteria in K3.1.2 (MC)’ confirm the following BM Unit Id……………………………………….. (repeat this table for each BM Unit Id in the MC configuration) | Select | Additional Details |
| Yes/No |
|
| Yes/No |
|
| Yes/No |
|
| Yes/No | If yes provide SVA MSID(s) ……………………………………………………………. |
| Yes/No | If yes provide details of the number and size of individual Plant and /or Apparatus and confirm that the total size is less than or equal to a Small Power Station for the appropriate region. ……………………………………………………………. |
Fuel Type (Directly Connected or Embedded Primary BM Units) – for use in calculation of CALF values | Tick |
Biofuel |
|
CCGT |
|
CVA Consumption |
|
Hydro |
|
OCGT |
|
Pumped Storage |
|
Rail Demand |
|
Station Load |
|
Onshore Wind |
|
Offshore Wind |
|
Other (please specify): |
|
Primary BM Unit and Associated CVA Metering Systems | |
Primary BM Unit | Associated CVA Metering Systems |
|
|
|
|
MPAN Mapping Details (Exemptable Embedded Sites registering Export in CVA and Import in SVA) | ||
MPAN | Effective From Date | Effective To Date |
|
|
|
|
|
|
BM Unit Group Details (Supplier BM Units containing SVA Metering system(s) which are part of a Teleswitch Group(s) which include SVA Metering Systems in a different Supplier’s BM Unit)
| ||
Teleswitch Group ID | Effective From Date | Effective To Date |
|
|
|
|
|
|
Switching Groups64 (list BM Unit Ids for each Switching Group below) Only applicable to a combination of Power Park Modules which belong to a Switching Group. |
(Example: Switching Group 1 – T_ABMU-1 and T_BBMU-1) |
|
|
To: CRA | Date Sent: | |
From: Participant Details | ||
Party ID: | Name of Sender: | |
Contact email address: | ||
Our Ref: | Contact Tel. No: | |
Name of Authorised Signatory: | ||
Authorised Signature: | Password: |
Is this Primary BM Unit de-registration: | |
[ ] | an Interconnector Primary BM Unit |
[ ] | a re-configuration of existing plant and apparatus into another Primary BM Unit |
[ ] | a disconnection of circuits from the Transmission System or Distribution System (NOTE: if this box is ticked the appropriate Certification of Disconnection must be provided). |
[ ] | subject to a Registration Transfer in accordance with BSCP68 |
[ ] | An Additional Primary BM Unit deregistration for CFD |
(Tick as appropriate) |
Name: |
|
Primary BM Unit Id: |
|
NGC BM Unit ID: |
|
Effective To Date: |
|
To: CRA | Date Sent: | |
From: Participant Details | ||
Party ID: | Name of Sender: | |
Contact email address: | ||
Our Ref: | Contact Tel. No. | |
Name of Authorised Signatory: | ||
Authorised Signature: | Password: |
BSC Season |
| Tick One |
|
| Spring | [ ] | 1st March to 31st May |
| Summer | [ ] | 1st June to 31st August |
| Autumn | [ ] | 1st September to 30th November |
| Winter | [ ] | 1st December to 28th / 29th February |
Primary BM Unit Id | Maximum (+ve) QMij MWh (for use in calculating GC) | Maximum (-ve) QMij MWh (for use in calculating DC) | Generation Capacity MW (+ve) | Demand Capacity MW (-ve) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
To: CRA | Date Sent: |
From: Participant Details | |
Party ID: | Name of Sender: |
Contact email address: | |
Our Ref: | Contact Tel. No. |
Name of Authorised Signatory: | |
Authorised Signature: | Password: |
Effective From Date: |
Primary BM Unit Id | Revised Maximum (+ve) QMij MWh (for use in calculating GC) | Revised Minimum (-ve) QMij MWh (for use in calculating DC) | Revised Generation Capacity MW (+ve) | Revised Demand Capacity MW (-ve) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
To: BSCCo | Date Sent: | |
From: Participant Details | ||
Party ID: | Name of Sender: | |
Contact email address: | ||
Our Ref: | Contact Tel. No. | |
Name of Authorised Signatory: | ||
Authorised Signature: | Password: |
Primary BM Unit ID | Generation Capacity (GC) MW | Demand Capacity (DC) MW | Metering System ID | Exempt Export status required by (date) | Chosen P/C Flag67 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Please explain why you believe the Generating Plant is Exemptable. You may wish to refer to the relevant Statutory Instrument: |
|
|
|
|
|
To: | Date Sent: | |
From: BSCCo | ||
Name of Sender: | ||
Contact email address: | ||
Our Ref: | Contact Tel. No. | |
Name of Authorised Signatory: | ||
Authorised Signature: | Password: |
Primary BM Unit ID | Declared Net Capacity (DNC) MW | Total Output to System MW | Exempt Export Primary BM Unit status Effective From (date) | Chosen P/C Flag |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Comments: |
|
|
|
|
Reasons: |
|
|
|
|
To: BSCCo | Date Sent: | |
From: Participant Details (Transferor) | ||
Party ID: | Name of Sender: | |
Contact email address: | ||
Our Ref: | Contact Tel. No. | |
| Contact Fax. No. | |
Name of Authorised Signatory: | ||
Authorised Signature: | Password: |
To: BSCCo | Date Sent: | |
From: Participant Details (Transferee) | ||
Party ID: | Name of Sender: | |
Contact email address: | ||
Our Ref: | Contact Tel. No. | |
| Contact Fax. No. | |
Name of Authorised Signatory: | ||
Authorised Signature: | Password: |
To: | CRA | Date Sent: | ||||||
From: BSCCo | ||||||||
Participant and Primary BM Unit Details | ||||||||
Party Id: |
| |||||||
Primary BM Unit ID: |
| |||||||
Commencement of Exempt Export Primary BM Unit Status: | YES / NO | |||||||
P/C Flag to apply:70 |
| |||||||
Effective From Settlement Date (for Exempt Export Flag and P/C Flag): |
| |||||||
Termination of Exempt Export Primary BM Unit Status: | YES / NO | |||||||
Effective To Settlement Date (for Exempt Export Flag and P/C Flag): |
|
| ||||||
Name of Authorised Signatory: | ||||||||
| ||||||||
Authorised Signature: |
| Password: |
| |||||
Contact email address: |
| |||||||
BSCCo Ref: |
| Contact Tel. No. |
|
To: CRA BSCCo | Date Sent: | |
From: Participant Details | ||
Party ID71: | Name of Sender: | |
Contact email address: | ||
Our Ref: | Contact Tel. No. | |
| ||
Name of Authorised Signatory: | ||
Authorised Signature: | Password: |
BM Unit ID:
P / C Flag: |
_____________________
PRODUCTION / CONSUMPTION72 (delete as applicable) | ||
| |||
| Effective From Settlement Date: |
| |
|
From: CRA73 | To: Lead Party | |
Date Sent: |
|
|
Reason(s) for Rejection: |
| |
|
| |
|
|
To: | BSCCo Certification of Exemptable Status for Generating Plant With Exports Measured by SVA Metering Systems | Date Sent: |
| ||||||
Primary BM Unit ID: |
|
| |||||||
| |||||||||
From: Company Details |
| ||||||||
Party Id: |
| Name of Sender: |
|
| |||||
Contact email address: |
|
|
| ||||||
Our Ref: |
| Contact Tel. No. |
|
| |||||
I, the Director of the Party responsible for and requesting Exemptable Generating Plant status for__________________________74, and thereby Exempt Export Primary BM Unit status for ____________________75, (‘the Party’) hereby certify that from 76: The Generating Plant is Exemptable as defined in Section K1.2.2 of the Code and the Primary BM Unit would, if the Metering Systems comprised in that Primary BM Unit(s) were CVA registered, satisfy the following criteria in accordance with Section K3.3A of the Code:
I hereby provide notification in accordance with Section K3.5 that the Party elects the P/C Flag of the Primary BM Unit to be _______ 77 should the Primary BM Unit be granted Exempt Export status. The Party will take all reasonable steps, in accordance with Section U1.2.3, to ensure that the data and information held or maintained by BSCCo, any BSC Agent, or any SMRA relating to the Party, with specific reference to this application, is and continues to be accurate and complete. BSCCo can rely on this certification as to the matters set out herein, for the purposes of verification of Exemptable Generating Plant status (and associated Exempt Export Primary BM Unit status), i.e. the matters set out above in (1) to (4). The Party undertakes to comply with any request to re-certify made by BSCCo in accordance with Section K 1.5.8. | |||||||||
Name of Director: | |||||||||
Signature of Director: | On behalf of: |
To: | BSC Party Confirmation of Exemptable Status for Generating Plant With Exports Measured by SVA Metering Systems | Date Sent: |
| |||||
Generating Plant Name: |
|
| ||||||
Primary BM Unit ID: |
| |||||||
Party Id: |
| Name of Sender: |
| |||||
Contact email address: |
|
|
| |||||
Our Ref: |
| Contact Tel. No. |
| |||||
From: BSCCo |
| |||||||
BSCCo hereby confirms that the above Generating Plant has / has not* been granted Exemptable status and that the above Primary BM Unit therefore has / has not* been granted Exempt Export status. BSCCo hereby also confirms that, where (and only where) Exempt Export status has been granted, the P/C Flag elected for the Primary BM Unit in Part A of this form BSCP15/4.9 shall become effective concurrently with the Primary BM Unit’s Exempt Export status. |
To: BSCCo | Date Sent: | |
From: Participant Details | ||
Party ID: | Name of Sender: | |
Contact email address: | ||
Our Ref: | Contact Tel. No. | |
Name of Authorised Signatory (Category A in BSCP38): | ||
Authorised Signature: | Password: |
The Party has acceded to the BSC and completed Party registration in the role of Supplier;
The Party has appropriate registration on the NETSO Systems, and use of a qualified Trading Agent and Trading Point.
The Primary BM Unit is not associated with a Trading Unit except a Sole Trading Unit; and
The de-registration form (BSCP15/4.2) and registration form (BSCP15/4.3) submitted by the outgoing and incoming Suppliers contain consecutive Effective To and From Dates (in order to demonstrate that both Suppliers are aware of, and agree with, the change of Lead Party).
To: Party | Date Sent: | ||
From: BSCCo | |||
Party ID: | Name of Sender: | ||
Contact email address: | |||
Our Ref: | Contact Tel. No. | ||
Name of Authorised Signatory (Category A in BSCP38): | |||
Authorised Signature: | Password: | ||
BSCCo hereby confirms that the above Party has/has not* met the necessary criteria to be included in the BSC Website list of Suppliers which have satisfied the criteria to complete a change of Primary BM Unit Lead Party within 5WDs for a Primary BM Unit with CVA metering and associated with a Customer premises. |
To: CRA | Date Sent: | |
From: Participant Details | ||
Party ID: | Name of Sender: | |
Contact email address: | ||
Our Ref: | Contact Tel. No. | |
| Contact Fax. No. | |
Name of Authorised Signatory: | ||
Authorised Signature: | Password: |
Primary BM Unit Id: | NGC Primary BM Unit ID (if known) | Associated MSIDs (please enter all MSIDs associated with Primary BM Unit) | Associated Approved Metering Dispensations (if applicable, please provide MSID(s) and Metering Dispensation Reference Number(s)) | Current P/C Flag (for Exempt Export Primary BM Units only)78 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Trading Unit Name (if applicable): |
|
To: CRA | Date Sent: | |
From: Participant Details | ||
Party ID: | Name of Sender: | |
Contact email address: | ||
Our Ref: | Contact Tel. No. | |
| Contact Fax. No. | |
Name of Authorised Signatory: | ||
Authorised Signature: | Password: |
Primary BM Unit Id: | NGC Primary BM Unit ID (if known) | Associated MSIDs (please enter all MSIDs associated with Primary BM Unit(s))80 | Associated Approved Metering Dispensations (if applicable, please provide relevant MSID(s) and Metering Dispensation Reference Number(s)) | Chosen P/C Flag (for Exempt Export Primary BM Units only)81 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Trading Unit Name: (if applicable) |
|
To: BSCCo | Date Sent: | |
From: Participant Details | ||
Party ID: | Name of Sender: | |
Contact email address: | ||
Our Ref: | Contact Tel. No. | |
| Contact Fax. No. | |
Name of Authorised Signatory | ||
Authorised Signature: | Password: |
This form with contact and Authorised Signatory details removed, associated diagrams and BSC Panel documents will routinely be made available in the public domain unless the applicant informs BSCCo otherwise at the time of application | ||||||||
Request for Confidentiality YES/NO* *Delete as applicable | ||||||||
If ‘YES’, what is confidential?
| ||||||||
Justification for requesting confidentiality:
|
Primary BM Unit Id(s) (if known): |
|
Primary BM Unit Name(s) (Max 30 Characters): |
|
NGC BM Unit Id(s) (if known and applicable): |
|
Why are you applying for a Non-Standard Primary BM Unit (please tick)
| ||||||
Description of Non-Standard Primary BM Unit configuration Please contact BSCCo for guidance on how to complete this section
| ||||||
Please provide electrical single line diagram(s) of the Plant and Apparatus included in the Non-Standard (and any Standard) Primary BM Unit(s) to support your application. The diagrams need to clearly show the location of the Metering Equipment, in particular the Settlement Current and Voltage Transformers (CTs/VTs) and CT/VT ratios, all existing Boundary Points and any System Connection Points at or near the proposed Boundary Point(s) and which items of Plant and Apparatus comprise which Non-Standard (and any Standard) Primary BM Unit(s). List of electrical single line diagrams attached and description of Plant and Apparatus covered by each diagram.
|
Rationale with reference to BSC Section K3.1 for the request for the Non-Standard Primary BM Unit: Please contact BSCCo for guidance on how to complete this section
|
To: CRA | Date Sent: |
From: Participant Details | |
Party ID84: | Name of Sender: |
Contact email address: | |
Our Ref: | Contact Tel. No. |
Name of Authorised Signatory: | |
Authorised Signature: | Password: |
Is this Secondary BM Unit registration: | |
[ ] | a New Secondary BM Unit Registration |
[ ] | a change in status of a Secondary BM Unit’s FPN Flag |
[ ] | Baselined BM Unit Indicator |
(Tick as appropriate) |
Secondary BM Unit Id | Secondary BM Unit Name(Max 30 Characters) | NGC BM Unit ID85 | GSP Group Id | P/C Flag | FPN Flag (Y/N) | Baselined BM Unit (Y/N) | EFD |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
To: CRA | Date Sent: | |
From: Participant Details | ||
Party ID: | Name of Sender: | |
Contact email address: | ||
Our Ref: | Contact Tel. No: | |
Name of Authorised Signatory: | ||
Authorised Signature: | Password: |
Name: |
|
Secondary BM Unit Id: |
|
NGC BM Unit ID: |
|
Effective To Date: |
|
1 Per section K3.1.4B, Power Park Modules may belong to a Switching Group on the basis that Plant and Apparatus can be selected to run in any of the BM Units belonging to that Switching Group. A ‘Switching Group’ is described in Section K3.1.4A of BSC.
2 Must be authorised by a Category A authorised signatory
3 Not required for Change of CVA Primary BM Unit Lead Party unless any changes are to be made to existing registration data.
4 If the CT / VT ratios are not known 30WD / 60WD prior to the EFD, this information should be sent separately by 16WD prior to the EFD.
5 If a Primary BM Unit registration is requested using Electronic File Data Transfer, the passwords and signatures are not required as the access control to the participant system is sufficient authentication.
6 Where the Party is applying to register two or more Offshore Power Park Modules as a Combined Offshore BM Unit, BSCCo recommends that the Party consults with the NETSO before submitting this form.
7 This information is required to help ensure the energy flow(s) for the proposed Boundary Point(s) are accounted for, where necessary (e.g. under an existing Metering Dispensation for difference metering), in the Aggregation Rules of any associated Volume Allocation Units (e.g. Interconnectors, other relevant BM Units, Grid Supply Points, GSP Groups or Distribution System Connection Points).
8 Suppliers that have Customers directly connected to the Transmission System can register and de-register the BM Unit associated with that Customer premises within 5WD if the criteria in Section 1.7 have been satisfied.
9 Where the Primary BM Unit has the FPN flag set to Yes the NETSO must be contacted at least 30 WD prior to EFD.
10 Metering Systems are registered in accordance with BSCP20
11 If the CT / VT ratios are not known 30WD / 60WD prior to the EFD, this information should be sent separately by 16WD prior to the EFD.
12 If a BM Unit registration is requested using Electronic File Data Transfer, the passwords and signatures are not required as the access control to the participant system is sufficient authentication.
13 Where the Party is applying to register 2 or more Offshore Power Park Modules as a Combined Offshore BM Unit, BSCCo recommends that the Party consults with the NETSO before submitting this form.
14 This information is required to help ensure the energy flow(s) for the proposed Boundary Point(s) are accounted for, where necessary (e.g. under an existing Metering Dispensation for difference metering), in the Aggregation Rules of any associated Volume Allocation Units (e.g. Interconnectors, other relevant BM Units, Grid Supply Points, GSP Groups or Distribution System Connection Points).
15 The TLM for an Interconnector BM Unit will be set to 1, irrespective of the value of the TLF
16 If the Primary Base BM Unit is an Exempt Export Primary BM Unit, the Lead Party can change the Primary BM Unit’s allocated Trading Unit by providing notification in accordance with BSCP31.
17 Note that, with the exception of any Exempt Export Primary BM Units in Base Trading Units which have explicitly elected to have a P/C Status of Production, all Primary BM Units in Base Trading Units will always have a P/C Status of Consumption in accordance with Section K3.5.
18 The EFD must align with MDD Release Schedule and be agreed between the NETSO, CRA, Party and BSCCo as applicable
19 If an Additional Primary BM Unit is requested using Electronic File Data Transfer, the passwords and signatures are not required as the access control to the participant system is sufficient authentication. Where faxes are used, participants are required to submit hard copies of the forms by post in case the faxed signatures are illegible.
20 If the Additional Primary BM Unit is an Exempt Export Primary BM Unit, the Lead Party can change the Primary BM Unit’s allocated Trading Unit by providing notification in accordance with BSCP31. If no notification is provided by the Lead Party, the Primary BM Unit will be allocated to the Base Trading Unit for its GSP Group.
21 Note that, with the exception of any Exempt Export BM Units in Base Trading Units which have explicitly elected to have a P/C Status of Production, all BM Units in Base Trading Units will always have a P/C Status of Consumption in accordance with Section K3.5.
22 Primary BM Unit registration timescales may be reduced in certain circumstances if the registering Party agrees that the registration will not be withdrawn or amended after the ‘point of no return’.
23 If the Primary BM Unit is an Embedded BM Unit, Party requests from LDSO. If the Primary BM Unit is a Directly Connected Primary BM Unit, Party requests from NETSO.
24 Any relevant Metering Systems should be de-registered in accordance with BSCP20
25 If a Primary BM Unit De-registration is requested using Electronic File Data Transfer, the passwords and signatures are not required as the access control to the participant system is sufficient authentication. Where faxes are used, participants are required to submit hard copies of the forms by post in case the faxed signatures are illegible.
26 Party to initiate BSCP509 before the de-registration form is submitted to the CRA
27 Where the Primary BM Unit has a FPN set to No, the NETSO does not need to be informed of the De-Registration
28 The Supplier needs to ensure all Metering Systems associated with the additional Supplier Primary BM Unit are re-allocated to either the Base Primary BM Unit or another Supplier BM Unit associated with the same GSP Group (BSCP503 & 507) unless circuits are being disconnected.
29 Notification of such Primary BM Units shall be sent to the SVAA in its capacity as the Market Domain Data manager
30 Please refer to the ‘Generation Capacity (GC) and Demand Capacity (DC) Estimation Methodology and Challenge Guidance’ document for guidance on this process.
31 If the GC or DC Breach has not been processed in time to be included in the CRA registration reports, then the Effective From Date for the CRA-estimated GC or DC value shall be set to the Working Day after next.
32 BSC Parties may elect to raise a GC or DC Estimation Challenge through the Self-Service Gateway, in which case both CRA and BSCCo will be notified, or they can email BSCCo, who will raise the GC or DC Estimation Challenge on their behalf.
33 If the CRA has two or more conflicting updates to Primary BM Unit Registration data with the same Effective From Date, it shall prioritise the updates in accordance with Section K3.4.7N and with Section K3.4.7O.
34 If the changes to the GC or DC Values has not been processed in time to be included in the CRA registration reports, then the Effective From Date shall be set to the Working Day after next.
35 The Lead Party can change an Exempt Export Primary BM Unit’s allocated Trading Unit by providing notification in accordance with BSCP31.
36 Once Exempt Export status is terminated, the Primary BM Unit’s P/C Status will no longer be fixed by the Lead Party and will be determined in accordance with Section K3.5.2.
37 The Lead Party can choose to register the Primary BM Unit in a different Trading Unit by following BSCP31.
38 Please note that the responsibility for providing accurate registration data on BSCP15/4.11 forms or in the relevant section of the Self-Service Gateway lies with the Lead Party and not BSCCo.
39 Where a CoPBLP involves multiple Primary BM Units affecting multiple Trading Units, a separate form should be used for each Trading Unit.
40 Because of the short timescales in which a Transfer of Supplier ID can occur, the Exempt Export Primary BM Unit’s P/C Status will remain unchanged on transfer to the Supplier ID Transferee unless the Supplier ID Transferee notifies the CRA/BSCCo to the contrary by following procedure 3.12.
41 The ELEXON Circular is only issued in the event of a Supplier of Last Resort (SoLR).
42 Primary BM Unit registration timescales may be reduced in certain circumstances if the registering Party agrees that the registration will not be withdrawn or amended after the ‘point of no return’
43 Typically this will be when the CFD comes to an end and the Additional Primary BM Unit is no longer required for CFD. Suppliers should ensure any MPANs are re-allocated to another appropriate Primary BM Unit. Any Metering Systems not re-allocated will be assigned to the relevant Supplier’s Base Primary BM Unit by SVAA.
44 BSCCo to initiate BSCP509 before the de-registration form is submitted to the CRA
45 Where the Primary BM Unit has a FPN set to No, the NETSO does not need to be informed of the De-Registration
46 The Supplier needs to ensure all Metering Systems associated with the additional Supplier Primary BM Unit are re-allocated to either the Base Primary BM Unit or another Supplier Primary BM Unit associated with the same GSP Group (BSCP503 & 507) unless circuits are being disconnected.
47 Notification of such Primary BM Units shall be sent to the SVAA in its capacity as the Market Domain Data manager
48 If a Secondary BM Unit De-registration is requested using Electronic File Data Transfer, the passwords and signatures are not required as the access control to the participant system is sufficient authentication. Where faxes are used, participants are required to submit hard copies of the forms by post in case the faxed signatures are illegible.
49 Where the Secondary BM Unit has a FPN set to No, the NETSO does not need to be informed of the De-Registration
50 If a BM Unit registration is requested using Electronic File Data Transfer, the passwords and signatures are not required as the access control to the participant system is sufficient authentication.
51 This information is required to help ensure the energy flow(s) for the proposed Boundary Point(s) are accounted for, where necessary (e.g. under an existing Metering Dispensation for difference metering), in the Aggregation Rules of any associated Volume Allocation Units (e.g. Interconnectors, other relevant BM Units, Grid Supply Points, GSP Groups or Distribution System Connection Points).
52 These reports would be sent if the CRA system had to be updated to reflect that change. They would not be sent if the only change was to the fuel type or the configuration of the BM Units as these parameters are not entered into the CRA system.
53 In the case of Base Primary BM Units this form should be used to complete the Base Primary BM Unit Registrations by providing, for example, the initial GC/DC values and if appropriate the FPN Flag.
54 Baselined BM Unit Indicator for Additional BM Unit Registrations only.
55 The NGC BM Unit ID must be provided for all Primary BM Units with the FPN Flag set to ‘Y’.
56 E – Embedded, I – Interconnector, G – Base Supplier S – Additional Supplier, T – Directly Connected
57 CCGT – CCGT registered in CMRS, PPM – a single Power Park Module registered in CMRS, COBMU – a Combined Offshore BM Unit comprising 2 or more Offshore Power Park Modules registered in CMRS, DC – Directly Connected Circuit at Customer (Supplied by BSC Party) Premises, DC+ – Directly Connected Circuit at Customer (Supplied by BSC Party) Premises through more than one Boundary Point, IC – Interconnector Primary Unit, BB – Primary Base BM Unit, AB – Additional Primary BM Unit, OPPM+ - Offshore PPM plus related Imports at separate Boundary Points, COBMU+ - COBMU plus related Imports at separate Boundary Points, MC – Meets criteria in BSC K3.1.2, NS – Non-Standard.
58 If unit type E or S
59 Only applicable for Interconnector Primary BM Units, which are registered in fixed Production/Consumption pairs whose P/C Status does not change (Section K3.5/K5.5). A Party applying for Exempt Export status must follow procedure 3.10 to elect the Exempt Export Primary BM Unit’s P/C Flag.
60 To apply for Exempt Export status for a new BM Unit registration, enter “Yes” and follow procedure 3.10 of this BSCP.
61 If BM Unit Type is I
62] For BM Unit Type is S Only
63 If the CT/VT ratios are not known 30WD / 60WD prior to the EFD, this information should be sent separately by 16WD prior to the EFD. If you are applying for Exempt Export status for an existing BM Unit, you do not need to complete form 4.1 but must follow procedure 3.10.
64 Note that this still applies where Switching Aggregation Rules are not required.
65 Where CFD Additional Primary BM Units are being de-registered, the de-registration details may be provided using spreadsheets or other suitable formats
66 If your application for Exemptable Generating Plant status is successful, the Primary BM Unit(s) comprising the Exemptable Generating Plant will be granted Exempt Export status. Please refer to procedure 3.10 for further details.
67 Please enter the P/C Flag (either “P” for Production or “C” for Consumption) that you as the Lead Party elect to apply to the Primary BM Unit from the date that the Primary BM Unit’s Exempt Export status (if granted) becomes effective. Failure to complete this box will result in rejection of this form and a delay to your application. Please refer to procedure 3.10 for further details.
68 The Trading Party that is transferring the Supplier ID(s)
69 The Trading Party that will become responsible for the Supplier ID(s)
70 Must be either “P” (Production) or “C” (Consumption); otherwise the CRA shall reject this form.
71 For Primary Exempt Export BM Units and / or Secondary BM Units.
72 Please refer to procedure 3.12 or 3.23 for further details.
73 Used for Exempt Export Primary BM Units if the request to change the P/C flag is rejected.
74 Add name of Generating Plant here.
75 Add Primary BM Unit Id here.
76 Add Exemptable Status Effective From date here
77 Please enter either “P” (Production) or “C” (Consumption). Failure to complete this election will result in rejection of this form and a delay to your application. Please refer to procedure 3.10 for further details.
78 Must be either "P” (Production) or “C” (Consumption).
79 The ‘Effective To Date’ specified on this form should be the day before the ‘Effective From Date’ for the associated registration(s) specified on the BSCP15/4.11 Part B form.
80 Please note, if the Party de-registering the Primary BM Unit is not the current Registrant of the MSID, permission should be sought from the current Registrant, in accordance with BSCP20, to ensure they have no objections to the transfer.
81 Please enter the P/C Flag (either “P” for Production or “C” for Consumption) that you elect to apply to the Exempt Export Primary BM Unit from the Effective From Date of the CoPBLP. Failure to complete this box will result in rejection of this form and a delay to the transfer. Please refer to procedure 3.13 for further details.
82 The ‘Effective From Date’ specified on this form should be the next consecutive day after the associated ‘Effective To Date’ for the deregistration(s) specified on the BSCP15/4.11 Part A form.
83 BSCCo will publish all Panel determinations, though for confidential papers the details will be anonymised. BSCCo is required to keep a list of all Non-Standard BM Unit determinations which must be made available to any Party upon request.
84 Only Virtual Lead Parties may register Secondary BM Units
85 The NGC BM Unit ID must be provided for all Secondary BM Units with the FPN Flag set to ‘Y’.